Cargando…
Improving Resolution of Dual-Comb Gas Detection Using Periodic Spectrum Alignment Method
Dual-comb spectroscopy has been an infusive spectroscopic tool for gas detection due to its high resolution, high sensitivity, and fast acquisition speed over a broad spectral range without any mechanical scanning components. However, the complexity and cost of high-performance dual-comb spectroscop...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7866286/ https://www.ncbi.nlm.nih.gov/pubmed/33572805 http://dx.doi.org/10.3390/s21030903 |
_version_ | 1783648046659141632 |
---|---|
author | Yu, Haoyang Zhou, Qian Li, Xinghui Wang, Xiaohao Wang, Xilin Ni, Kai |
author_facet | Yu, Haoyang Zhou, Qian Li, Xinghui Wang, Xiaohao Wang, Xilin Ni, Kai |
author_sort | Yu, Haoyang |
collection | PubMed |
description | Dual-comb spectroscopy has been an infusive spectroscopic tool for gas detection due to its high resolution, high sensitivity, and fast acquisition speed over a broad spectral range without any mechanical scanning components. However, the complexity and cost of high-performance dual-comb spectroscopy are still high for field-deployed applications. To solve this problem, we propose a simple frequency domain post-processing method by extracting the accurate position of a specific absorption line frame by frame. After aligning real-time spectra and averaging for one second, the absorbance spectrum of H(13)C(14)N gas in the near-infrared is obtained over 1.1 THz spectral range. By using this method, the standard deviation of residual error is only ~0.002, showing great agreement with the conventional correction method. In addition, the spectral resolution is improved from 13.4 GHz to 4.3 GHz compared to direct spectrum averaging. Our method does not require a specially designed common-mode suppression comb, rigorous frequency control system, or complicated computational algorithm, providing a cost-effective scheme for field-deployed Doppler-limited spectroscopy applications. |
format | Online Article Text |
id | pubmed-7866286 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-78662862021-02-07 Improving Resolution of Dual-Comb Gas Detection Using Periodic Spectrum Alignment Method Yu, Haoyang Zhou, Qian Li, Xinghui Wang, Xiaohao Wang, Xilin Ni, Kai Sensors (Basel) Letter Dual-comb spectroscopy has been an infusive spectroscopic tool for gas detection due to its high resolution, high sensitivity, and fast acquisition speed over a broad spectral range without any mechanical scanning components. However, the complexity and cost of high-performance dual-comb spectroscopy are still high for field-deployed applications. To solve this problem, we propose a simple frequency domain post-processing method by extracting the accurate position of a specific absorption line frame by frame. After aligning real-time spectra and averaging for one second, the absorbance spectrum of H(13)C(14)N gas in the near-infrared is obtained over 1.1 THz spectral range. By using this method, the standard deviation of residual error is only ~0.002, showing great agreement with the conventional correction method. In addition, the spectral resolution is improved from 13.4 GHz to 4.3 GHz compared to direct spectrum averaging. Our method does not require a specially designed common-mode suppression comb, rigorous frequency control system, or complicated computational algorithm, providing a cost-effective scheme for field-deployed Doppler-limited spectroscopy applications. MDPI 2021-01-29 /pmc/articles/PMC7866286/ /pubmed/33572805 http://dx.doi.org/10.3390/s21030903 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Letter Yu, Haoyang Zhou, Qian Li, Xinghui Wang, Xiaohao Wang, Xilin Ni, Kai Improving Resolution of Dual-Comb Gas Detection Using Periodic Spectrum Alignment Method |
title | Improving Resolution of Dual-Comb Gas Detection Using Periodic Spectrum Alignment Method |
title_full | Improving Resolution of Dual-Comb Gas Detection Using Periodic Spectrum Alignment Method |
title_fullStr | Improving Resolution of Dual-Comb Gas Detection Using Periodic Spectrum Alignment Method |
title_full_unstemmed | Improving Resolution of Dual-Comb Gas Detection Using Periodic Spectrum Alignment Method |
title_short | Improving Resolution of Dual-Comb Gas Detection Using Periodic Spectrum Alignment Method |
title_sort | improving resolution of dual-comb gas detection using periodic spectrum alignment method |
topic | Letter |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7866286/ https://www.ncbi.nlm.nih.gov/pubmed/33572805 http://dx.doi.org/10.3390/s21030903 |
work_keys_str_mv | AT yuhaoyang improvingresolutionofdualcombgasdetectionusingperiodicspectrumalignmentmethod AT zhouqian improvingresolutionofdualcombgasdetectionusingperiodicspectrumalignmentmethod AT lixinghui improvingresolutionofdualcombgasdetectionusingperiodicspectrumalignmentmethod AT wangxiaohao improvingresolutionofdualcombgasdetectionusingperiodicspectrumalignmentmethod AT wangxilin improvingresolutionofdualcombgasdetectionusingperiodicspectrumalignmentmethod AT nikai improvingresolutionofdualcombgasdetectionusingperiodicspectrumalignmentmethod |