Cargando…

Improving Resolution of Dual-Comb Gas Detection Using Periodic Spectrum Alignment Method

Dual-comb spectroscopy has been an infusive spectroscopic tool for gas detection due to its high resolution, high sensitivity, and fast acquisition speed over a broad spectral range without any mechanical scanning components. However, the complexity and cost of high-performance dual-comb spectroscop...

Descripción completa

Detalles Bibliográficos
Autores principales: Yu, Haoyang, Zhou, Qian, Li, Xinghui, Wang, Xiaohao, Wang, Xilin, Ni, Kai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7866286/
https://www.ncbi.nlm.nih.gov/pubmed/33572805
http://dx.doi.org/10.3390/s21030903
_version_ 1783648046659141632
author Yu, Haoyang
Zhou, Qian
Li, Xinghui
Wang, Xiaohao
Wang, Xilin
Ni, Kai
author_facet Yu, Haoyang
Zhou, Qian
Li, Xinghui
Wang, Xiaohao
Wang, Xilin
Ni, Kai
author_sort Yu, Haoyang
collection PubMed
description Dual-comb spectroscopy has been an infusive spectroscopic tool for gas detection due to its high resolution, high sensitivity, and fast acquisition speed over a broad spectral range without any mechanical scanning components. However, the complexity and cost of high-performance dual-comb spectroscopy are still high for field-deployed applications. To solve this problem, we propose a simple frequency domain post-processing method by extracting the accurate position of a specific absorption line frame by frame. After aligning real-time spectra and averaging for one second, the absorbance spectrum of H(13)C(14)N gas in the near-infrared is obtained over 1.1 THz spectral range. By using this method, the standard deviation of residual error is only ~0.002, showing great agreement with the conventional correction method. In addition, the spectral resolution is improved from 13.4 GHz to 4.3 GHz compared to direct spectrum averaging. Our method does not require a specially designed common-mode suppression comb, rigorous frequency control system, or complicated computational algorithm, providing a cost-effective scheme for field-deployed Doppler-limited spectroscopy applications.
format Online
Article
Text
id pubmed-7866286
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-78662862021-02-07 Improving Resolution of Dual-Comb Gas Detection Using Periodic Spectrum Alignment Method Yu, Haoyang Zhou, Qian Li, Xinghui Wang, Xiaohao Wang, Xilin Ni, Kai Sensors (Basel) Letter Dual-comb spectroscopy has been an infusive spectroscopic tool for gas detection due to its high resolution, high sensitivity, and fast acquisition speed over a broad spectral range without any mechanical scanning components. However, the complexity and cost of high-performance dual-comb spectroscopy are still high for field-deployed applications. To solve this problem, we propose a simple frequency domain post-processing method by extracting the accurate position of a specific absorption line frame by frame. After aligning real-time spectra and averaging for one second, the absorbance spectrum of H(13)C(14)N gas in the near-infrared is obtained over 1.1 THz spectral range. By using this method, the standard deviation of residual error is only ~0.002, showing great agreement with the conventional correction method. In addition, the spectral resolution is improved from 13.4 GHz to 4.3 GHz compared to direct spectrum averaging. Our method does not require a specially designed common-mode suppression comb, rigorous frequency control system, or complicated computational algorithm, providing a cost-effective scheme for field-deployed Doppler-limited spectroscopy applications. MDPI 2021-01-29 /pmc/articles/PMC7866286/ /pubmed/33572805 http://dx.doi.org/10.3390/s21030903 Text en © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Letter
Yu, Haoyang
Zhou, Qian
Li, Xinghui
Wang, Xiaohao
Wang, Xilin
Ni, Kai
Improving Resolution of Dual-Comb Gas Detection Using Periodic Spectrum Alignment Method
title Improving Resolution of Dual-Comb Gas Detection Using Periodic Spectrum Alignment Method
title_full Improving Resolution of Dual-Comb Gas Detection Using Periodic Spectrum Alignment Method
title_fullStr Improving Resolution of Dual-Comb Gas Detection Using Periodic Spectrum Alignment Method
title_full_unstemmed Improving Resolution of Dual-Comb Gas Detection Using Periodic Spectrum Alignment Method
title_short Improving Resolution of Dual-Comb Gas Detection Using Periodic Spectrum Alignment Method
title_sort improving resolution of dual-comb gas detection using periodic spectrum alignment method
topic Letter
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7866286/
https://www.ncbi.nlm.nih.gov/pubmed/33572805
http://dx.doi.org/10.3390/s21030903
work_keys_str_mv AT yuhaoyang improvingresolutionofdualcombgasdetectionusingperiodicspectrumalignmentmethod
AT zhouqian improvingresolutionofdualcombgasdetectionusingperiodicspectrumalignmentmethod
AT lixinghui improvingresolutionofdualcombgasdetectionusingperiodicspectrumalignmentmethod
AT wangxiaohao improvingresolutionofdualcombgasdetectionusingperiodicspectrumalignmentmethod
AT wangxilin improvingresolutionofdualcombgasdetectionusingperiodicspectrumalignmentmethod
AT nikai improvingresolutionofdualcombgasdetectionusingperiodicspectrumalignmentmethod