In vitro comparison of two photostimulable phosphor plate systems for early detection of occlusal dentin caries with and without a sharpening filter

Background. Dental caries is the most important reason for tooth loss. Clinical examination is the most commonly used technique for occlusal caries diagnosis. The diagnostic power of digital systems is a matter of controversy in this field. The present study aimed to determine the diagnostic accurac...

Descripción completa

Detalles Bibliográficos
Autores principales: Bardal, Roghieh, Mobini, Mahshid, Mirzaee, Matin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tabriz University of Medical Sciences 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7867687/
https://www.ncbi.nlm.nih.gov/pubmed/33575011
http://dx.doi.org/10.34172/joddd.2020.046
_version_ 1783648326168608768
author Bardal, Roghieh
Mobini, Mahshid
Mirzaee, Matin
author_facet Bardal, Roghieh
Mobini, Mahshid
Mirzaee, Matin
author_sort Bardal, Roghieh
collection PubMed
description Background. Dental caries is the most important reason for tooth loss. Clinical examination is the most commonly used technique for occlusal caries diagnosis. The diagnostic power of digital systems is a matter of controversy in this field. The present study aimed to determine the diagnostic accuracy of two photostimulable phosphor plate (PSP) systems for early occlusal dentin caries in vitro. Methods. Sixty-nine extracted molar and premolar teeth were used in this study. The teeth were mounted in triple blocks, and standard radiographs were taken by the Digora and Acteon digital radiographic systems. The original and filter 1-enhanced radiographs were evaluated by two experienced observers twice at an interval of two weeks, and dentin caries was recorded in Tables prepared for the study. The teeth were then sectioned in a buccolingual direction and evaluated under a stereomicroscope. The observers’ reports were compared with microscopic findings as the gold standard. SPSS 23 was used to calculate the kappa coefficient, sensitivity, specificity, and area under the ROC curve (AUC). Statistical significance was set at P<0.05. Results. The internal and the external agreements in both imaging systems were good to excellent. The means of sensitivity, specificity, and AUC in the Acteon system were 34.1, 92.9, and 0.674, with 30.8, 94.8, and 0.659, respectively, in the Digora system. Conclusion. The accuracy of early occlusal caries diagnosis was poor on both systems, and no significant difference was observed between the two systems at a 95% confidence interval. Although the AUC was slightly higher in the original images, there was no significant difference between them; however, due to their high specificity, they can prevent unnecessary treatments in the clinic.
format Online
Article
Text
id pubmed-7867687
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Tabriz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-78676872021-02-10 In vitro comparison of two photostimulable phosphor plate systems for early detection of occlusal dentin caries with and without a sharpening filter Bardal, Roghieh Mobini, Mahshid Mirzaee, Matin J Dent Res Dent Clin Dent Prospects Original Article Background. Dental caries is the most important reason for tooth loss. Clinical examination is the most commonly used technique for occlusal caries diagnosis. The diagnostic power of digital systems is a matter of controversy in this field. The present study aimed to determine the diagnostic accuracy of two photostimulable phosphor plate (PSP) systems for early occlusal dentin caries in vitro. Methods. Sixty-nine extracted molar and premolar teeth were used in this study. The teeth were mounted in triple blocks, and standard radiographs were taken by the Digora and Acteon digital radiographic systems. The original and filter 1-enhanced radiographs were evaluated by two experienced observers twice at an interval of two weeks, and dentin caries was recorded in Tables prepared for the study. The teeth were then sectioned in a buccolingual direction and evaluated under a stereomicroscope. The observers’ reports were compared with microscopic findings as the gold standard. SPSS 23 was used to calculate the kappa coefficient, sensitivity, specificity, and area under the ROC curve (AUC). Statistical significance was set at P<0.05. Results. The internal and the external agreements in both imaging systems were good to excellent. The means of sensitivity, specificity, and AUC in the Acteon system were 34.1, 92.9, and 0.674, with 30.8, 94.8, and 0.659, respectively, in the Digora system. Conclusion. The accuracy of early occlusal caries diagnosis was poor on both systems, and no significant difference was observed between the two systems at a 95% confidence interval. Although the AUC was slightly higher in the original images, there was no significant difference between them; however, due to their high specificity, they can prevent unnecessary treatments in the clinic. Tabriz University of Medical Sciences 2020 2020-12-06 /pmc/articles/PMC7867687/ /pubmed/33575011 http://dx.doi.org/10.34172/joddd.2020.046 Text en ©2020 The Author(s). http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Bardal, Roghieh
Mobini, Mahshid
Mirzaee, Matin
In vitro comparison of two photostimulable phosphor plate systems for early detection of occlusal dentin caries with and without a sharpening filter
title In vitro comparison of two photostimulable phosphor plate systems for early detection of occlusal dentin caries with and without a sharpening filter
title_full In vitro comparison of two photostimulable phosphor plate systems for early detection of occlusal dentin caries with and without a sharpening filter
title_fullStr In vitro comparison of two photostimulable phosphor plate systems for early detection of occlusal dentin caries with and without a sharpening filter
title_full_unstemmed In vitro comparison of two photostimulable phosphor plate systems for early detection of occlusal dentin caries with and without a sharpening filter
title_short In vitro comparison of two photostimulable phosphor plate systems for early detection of occlusal dentin caries with and without a sharpening filter
title_sort in vitro comparison of two photostimulable phosphor plate systems for early detection of occlusal dentin caries with and without a sharpening filter
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7867687/
https://www.ncbi.nlm.nih.gov/pubmed/33575011
http://dx.doi.org/10.34172/joddd.2020.046
work_keys_str_mv AT bardalroghieh invitrocomparisonoftwophotostimulablephosphorplatesystemsforearlydetectionofocclusaldentincarieswithandwithoutasharpeningfilter
AT mobinimahshid invitrocomparisonoftwophotostimulablephosphorplatesystemsforearlydetectionofocclusaldentincarieswithandwithoutasharpeningfilter
AT mirzaeematin invitrocomparisonoftwophotostimulablephosphorplatesystemsforearlydetectionofocclusaldentincarieswithandwithoutasharpeningfilter