Polar value analysis of astigmatic change and rotational stability after implantation of V4c toric implantable collamer lens

BACKGROUND: To evaluate the clinical results and rotational stability of V4c toric implantable collamer lens (TICL, STAAR Surgical Company, Monrovia, CA, USA) in patients with moderate to high myopic astigmatism. Retrospective, interventional case series was performed at Shenzhen Eye Hospital, Shenz...

Descripción completa

Detalles Bibliográficos
Autores principales: Nie, Danyao, Yan, Pisong, Yan, Zonghui, Zhang, Jing, He, Wenling, Li, Ming, Sun, Liangnan, Huang, Mingquan, Liu, Xinhua, Lin, Haotian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7867885/
https://www.ncbi.nlm.nih.gov/pubmed/33569441
http://dx.doi.org/10.21037/atm-20-7835
_version_ 1783648365808975872
author Nie, Danyao
Yan, Pisong
Yan, Zonghui
Zhang, Jing
He, Wenling
Li, Ming
Sun, Liangnan
Huang, Mingquan
Liu, Xinhua
Lin, Haotian
author_facet Nie, Danyao
Yan, Pisong
Yan, Zonghui
Zhang, Jing
He, Wenling
Li, Ming
Sun, Liangnan
Huang, Mingquan
Liu, Xinhua
Lin, Haotian
author_sort Nie, Danyao
collection PubMed
description BACKGROUND: To evaluate the clinical results and rotational stability of V4c toric implantable collamer lens (TICL, STAAR Surgical Company, Monrovia, CA, USA) in patients with moderate to high myopic astigmatism. Retrospective, interventional case series was performed at Shenzhen Eye Hospital, Shenzhen, Guangdong, China. METHODS: This study enrolled 43 patients (72 eyes) who received TICL implantation to correct myopia and myopic astigmatism. The patients underwent visual and refractive examinations before and 1 month after surgery. Astigmatic changes were estimated using polar value analysis. The difference between the achieved axis and the intended axis at the last follow-up was taken as the rotation of the V4c TICL. RESULTS: At 1 month postoperatively, the mean safety and efficacy indices were 1.17 and 1.13, respectively. A significant reduction of 8.92±2.58 D was observed in the spherical equivalent refraction (SER), which decreased from −9.29±2.41 D preoperatively to −0.37±0.55 D postoperatively. The astigmatic error of treatment in cylinder format was calculated to 0.50±0.41 @ 15.08° relative to the preoperative stronger meridian at 1 month, postoperatively. At 1 month postoperatively, the mean absolute rotation was 8.30±10.00 degrees (median =5.46 degrees; range, 0.00–58.88 degrees). CONCLUSIONS: TICL could achieve good astigmatic outcomes for correcting moderate to high myopic astigmatism. After TICL implantation, corneal astigmatism remained unchanged. To optimize postoperative astigmatic outcomes in TICL, polar value analysis can be used to build a nomogram.
format Online
Article
Text
id pubmed-7867885
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-78678852021-02-09 Polar value analysis of astigmatic change and rotational stability after implantation of V4c toric implantable collamer lens Nie, Danyao Yan, Pisong Yan, Zonghui Zhang, Jing He, Wenling Li, Ming Sun, Liangnan Huang, Mingquan Liu, Xinhua Lin, Haotian Ann Transl Med Original Article BACKGROUND: To evaluate the clinical results and rotational stability of V4c toric implantable collamer lens (TICL, STAAR Surgical Company, Monrovia, CA, USA) in patients with moderate to high myopic astigmatism. Retrospective, interventional case series was performed at Shenzhen Eye Hospital, Shenzhen, Guangdong, China. METHODS: This study enrolled 43 patients (72 eyes) who received TICL implantation to correct myopia and myopic astigmatism. The patients underwent visual and refractive examinations before and 1 month after surgery. Astigmatic changes were estimated using polar value analysis. The difference between the achieved axis and the intended axis at the last follow-up was taken as the rotation of the V4c TICL. RESULTS: At 1 month postoperatively, the mean safety and efficacy indices were 1.17 and 1.13, respectively. A significant reduction of 8.92±2.58 D was observed in the spherical equivalent refraction (SER), which decreased from −9.29±2.41 D preoperatively to −0.37±0.55 D postoperatively. The astigmatic error of treatment in cylinder format was calculated to 0.50±0.41 @ 15.08° relative to the preoperative stronger meridian at 1 month, postoperatively. At 1 month postoperatively, the mean absolute rotation was 8.30±10.00 degrees (median =5.46 degrees; range, 0.00–58.88 degrees). CONCLUSIONS: TICL could achieve good astigmatic outcomes for correcting moderate to high myopic astigmatism. After TICL implantation, corneal astigmatism remained unchanged. To optimize postoperative astigmatic outcomes in TICL, polar value analysis can be used to build a nomogram. AME Publishing Company 2021-01 /pmc/articles/PMC7867885/ /pubmed/33569441 http://dx.doi.org/10.21037/atm-20-7835 Text en 2021 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Nie, Danyao
Yan, Pisong
Yan, Zonghui
Zhang, Jing
He, Wenling
Li, Ming
Sun, Liangnan
Huang, Mingquan
Liu, Xinhua
Lin, Haotian
Polar value analysis of astigmatic change and rotational stability after implantation of V4c toric implantable collamer lens
title Polar value analysis of astigmatic change and rotational stability after implantation of V4c toric implantable collamer lens
title_full Polar value analysis of astigmatic change and rotational stability after implantation of V4c toric implantable collamer lens
title_fullStr Polar value analysis of astigmatic change and rotational stability after implantation of V4c toric implantable collamer lens
title_full_unstemmed Polar value analysis of astigmatic change and rotational stability after implantation of V4c toric implantable collamer lens
title_short Polar value analysis of astigmatic change and rotational stability after implantation of V4c toric implantable collamer lens
title_sort polar value analysis of astigmatic change and rotational stability after implantation of v4c toric implantable collamer lens
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7867885/
https://www.ncbi.nlm.nih.gov/pubmed/33569441
http://dx.doi.org/10.21037/atm-20-7835
work_keys_str_mv AT niedanyao polarvalueanalysisofastigmaticchangeandrotationalstabilityafterimplantationofv4ctoricimplantablecollamerlens
AT yanpisong polarvalueanalysisofastigmaticchangeandrotationalstabilityafterimplantationofv4ctoricimplantablecollamerlens
AT yanzonghui polarvalueanalysisofastigmaticchangeandrotationalstabilityafterimplantationofv4ctoricimplantablecollamerlens
AT zhangjing polarvalueanalysisofastigmaticchangeandrotationalstabilityafterimplantationofv4ctoricimplantablecollamerlens
AT hewenling polarvalueanalysisofastigmaticchangeandrotationalstabilityafterimplantationofv4ctoricimplantablecollamerlens
AT liming polarvalueanalysisofastigmaticchangeandrotationalstabilityafterimplantationofv4ctoricimplantablecollamerlens
AT sunliangnan polarvalueanalysisofastigmaticchangeandrotationalstabilityafterimplantationofv4ctoricimplantablecollamerlens
AT huangmingquan polarvalueanalysisofastigmaticchangeandrotationalstabilityafterimplantationofv4ctoricimplantablecollamerlens
AT liuxinhua polarvalueanalysisofastigmaticchangeandrotationalstabilityafterimplantationofv4ctoricimplantablecollamerlens
AT linhaotian polarvalueanalysisofastigmaticchangeandrotationalstabilityafterimplantationofv4ctoricimplantablecollamerlens