Cargando…
Influence of Breast Density on Patient's Compliance during Ultrasound Examination: Conventional Handheld Breast Ultrasound Compared to Automated Breast Ultrasound
BACKGROUND: Our aim was to study the influence of breast density on patient's compliance during conventional handheld breast ultrasound (US) or automated breast US (ABUS), which could be used as adjunct screening modalities. METHODS: Between January 2019 and June 2019, 221 patients (mean age: 5...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7869737/ https://www.ncbi.nlm.nih.gov/pubmed/33659162 http://dx.doi.org/10.4103/JMU.JMU_13_20 |
_version_ | 1783648686434156544 |
---|---|
author | De Giorgis, Sara Brunetti, Nicole Zawaideh, Jeries Rossi, Federica Calabrese, Massimo Tagliafico, Alberto Stefano |
author_facet | De Giorgis, Sara Brunetti, Nicole Zawaideh, Jeries Rossi, Federica Calabrese, Massimo Tagliafico, Alberto Stefano |
author_sort | De Giorgis, Sara |
collection | PubMed |
description | BACKGROUND: Our aim was to study the influence of breast density on patient's compliance during conventional handheld breast ultrasound (US) or automated breast US (ABUS), which could be used as adjunct screening modalities. METHODS: Between January 2019 and June 2019, 221 patients (mean age: 53; age range: 24–89 years) underwent both US and ABUS. All participants had independently interpreted US and ABUS regarding patient compliance. The diagnostic experience with US or ABUS was described with a modified testing morbidity index (TMI). The scale ranged from 0 (worst possible experience) to 5 (acceptable experience). Standard statistics was used to compare the data of US and data of ABUS. Breast density was recorded with the Breast Imaging Reporting and Data System (BI-RADS) score. RESULTS: The mean TMI score was 4.6 ± 0.5 for US and 4.3 ± 0.8 for ABUS. The overall difference between patients' experience on US and ABUS was statistically significant with P < 0.0001. The difference between patients' experience on US and ABUS in women with BI-RADS C and D for breast density was statistically significant with P < 0.02 in favor of US (4.7 ± 0.4) versus 4.5 ± 0.6 for ABUS. Patients' experience with breast density B was better for US (4.7 ± 0.4) versus 4.3 ± 0.6 for ABUS with P < 0.01. Pain or discomfort occurred during testing, especially in patients >40 years. CONCLUSION: Patient age (>40 years) is a significant predictor of decreased compliance to ABUS. Compliance of ABUS resulted lower that of US independently for breast density. |
format | Online Article Text |
id | pubmed-7869737 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-78697372021-03-02 Influence of Breast Density on Patient's Compliance during Ultrasound Examination: Conventional Handheld Breast Ultrasound Compared to Automated Breast Ultrasound De Giorgis, Sara Brunetti, Nicole Zawaideh, Jeries Rossi, Federica Calabrese, Massimo Tagliafico, Alberto Stefano J Med Ultrasound Original Article BACKGROUND: Our aim was to study the influence of breast density on patient's compliance during conventional handheld breast ultrasound (US) or automated breast US (ABUS), which could be used as adjunct screening modalities. METHODS: Between January 2019 and June 2019, 221 patients (mean age: 53; age range: 24–89 years) underwent both US and ABUS. All participants had independently interpreted US and ABUS regarding patient compliance. The diagnostic experience with US or ABUS was described with a modified testing morbidity index (TMI). The scale ranged from 0 (worst possible experience) to 5 (acceptable experience). Standard statistics was used to compare the data of US and data of ABUS. Breast density was recorded with the Breast Imaging Reporting and Data System (BI-RADS) score. RESULTS: The mean TMI score was 4.6 ± 0.5 for US and 4.3 ± 0.8 for ABUS. The overall difference between patients' experience on US and ABUS was statistically significant with P < 0.0001. The difference between patients' experience on US and ABUS in women with BI-RADS C and D for breast density was statistically significant with P < 0.02 in favor of US (4.7 ± 0.4) versus 4.5 ± 0.6 for ABUS. Patients' experience with breast density B was better for US (4.7 ± 0.4) versus 4.3 ± 0.6 for ABUS with P < 0.01. Pain or discomfort occurred during testing, especially in patients >40 years. CONCLUSION: Patient age (>40 years) is a significant predictor of decreased compliance to ABUS. Compliance of ABUS resulted lower that of US independently for breast density. Wolters Kluwer - Medknow 2020-06-04 /pmc/articles/PMC7869737/ /pubmed/33659162 http://dx.doi.org/10.4103/JMU.JMU_13_20 Text en Copyright: © 2020 Journal of Medical Ultrasound http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article De Giorgis, Sara Brunetti, Nicole Zawaideh, Jeries Rossi, Federica Calabrese, Massimo Tagliafico, Alberto Stefano Influence of Breast Density on Patient's Compliance during Ultrasound Examination: Conventional Handheld Breast Ultrasound Compared to Automated Breast Ultrasound |
title | Influence of Breast Density on Patient's Compliance during Ultrasound Examination: Conventional Handheld Breast Ultrasound Compared to Automated Breast Ultrasound |
title_full | Influence of Breast Density on Patient's Compliance during Ultrasound Examination: Conventional Handheld Breast Ultrasound Compared to Automated Breast Ultrasound |
title_fullStr | Influence of Breast Density on Patient's Compliance during Ultrasound Examination: Conventional Handheld Breast Ultrasound Compared to Automated Breast Ultrasound |
title_full_unstemmed | Influence of Breast Density on Patient's Compliance during Ultrasound Examination: Conventional Handheld Breast Ultrasound Compared to Automated Breast Ultrasound |
title_short | Influence of Breast Density on Patient's Compliance during Ultrasound Examination: Conventional Handheld Breast Ultrasound Compared to Automated Breast Ultrasound |
title_sort | influence of breast density on patient's compliance during ultrasound examination: conventional handheld breast ultrasound compared to automated breast ultrasound |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7869737/ https://www.ncbi.nlm.nih.gov/pubmed/33659162 http://dx.doi.org/10.4103/JMU.JMU_13_20 |
work_keys_str_mv | AT degiorgissara influenceofbreastdensityonpatientscomplianceduringultrasoundexaminationconventionalhandheldbreastultrasoundcomparedtoautomatedbreastultrasound AT brunettinicole influenceofbreastdensityonpatientscomplianceduringultrasoundexaminationconventionalhandheldbreastultrasoundcomparedtoautomatedbreastultrasound AT zawaidehjeries influenceofbreastdensityonpatientscomplianceduringultrasoundexaminationconventionalhandheldbreastultrasoundcomparedtoautomatedbreastultrasound AT rossifederica influenceofbreastdensityonpatientscomplianceduringultrasoundexaminationconventionalhandheldbreastultrasoundcomparedtoautomatedbreastultrasound AT calabresemassimo influenceofbreastdensityonpatientscomplianceduringultrasoundexaminationconventionalhandheldbreastultrasoundcomparedtoautomatedbreastultrasound AT tagliaficoalbertostefano influenceofbreastdensityonpatientscomplianceduringultrasoundexaminationconventionalhandheldbreastultrasoundcomparedtoautomatedbreastultrasound |