Cargando…
Compatibility and Validation of a Recent Developed Artificial Blood through the Vascular Phantom Using Doppler Ultrasound Color- and Motion-mode Techniques
BACKGROUND: Doppler technique is a technology that can raise the predictive, diagnostic, and monitoring abilities in blood flow and suitable for researchers. The application depends on Doppler shift (shift frequencies), wherein the movement of red blood cells away from the probe is determined by the...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7869744/ https://www.ncbi.nlm.nih.gov/pubmed/33659160 http://dx.doi.org/10.4103/JMU.JMU_116_19 |
_version_ | 1783648688094052352 |
---|---|
author | Alshipli, Marwan Sayah, Mohannad Adel Oglat, Ammar A. |
author_facet | Alshipli, Marwan Sayah, Mohannad Adel Oglat, Ammar A. |
author_sort | Alshipli, Marwan |
collection | PubMed |
description | BACKGROUND: Doppler technique is a technology that can raise the predictive, diagnostic, and monitoring abilities in blood flow and suitable for researchers. The application depends on Doppler shift (shift frequencies), wherein the movement of red blood cells away from the probe is determined by the decrease or increase in the ultrasound (US) frequency. METHODS: In this experiment, the clinical US (Hitachi Avious [HI] model) system was used as a primary instrument for data acquisition and test the compatibility, efficacy, and validation of artificial blood (blood-mimicking fluid [BMF]) by color- and motion-mode. This BMF was prepared for use in the Doppler flow phantom. RESULTS: The motion of BMF through the vessel-mimicking material (VMM) was parallel and the flow was laminar and in the straight form (regular flow of BMF inside the VMM). Moreover, the scale of color velocity in the normal range at that flow rate was in the normal range. CONCLUSION: The new BMF that is being valid and effective in utilizing for US in vitro research applications. In addition, the clinical US ([HI] model) system can be used as a suitable instrument for data acquisition and test the compatibility, efficacy, and validation at in vitro applications (BMF, flow phantom components). |
format | Online Article Text |
id | pubmed-7869744 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-78697442021-03-02 Compatibility and Validation of a Recent Developed Artificial Blood through the Vascular Phantom Using Doppler Ultrasound Color- and Motion-mode Techniques Alshipli, Marwan Sayah, Mohannad Adel Oglat, Ammar A. J Med Ultrasound Original Article BACKGROUND: Doppler technique is a technology that can raise the predictive, diagnostic, and monitoring abilities in blood flow and suitable for researchers. The application depends on Doppler shift (shift frequencies), wherein the movement of red blood cells away from the probe is determined by the decrease or increase in the ultrasound (US) frequency. METHODS: In this experiment, the clinical US (Hitachi Avious [HI] model) system was used as a primary instrument for data acquisition and test the compatibility, efficacy, and validation of artificial blood (blood-mimicking fluid [BMF]) by color- and motion-mode. This BMF was prepared for use in the Doppler flow phantom. RESULTS: The motion of BMF through the vessel-mimicking material (VMM) was parallel and the flow was laminar and in the straight form (regular flow of BMF inside the VMM). Moreover, the scale of color velocity in the normal range at that flow rate was in the normal range. CONCLUSION: The new BMF that is being valid and effective in utilizing for US in vitro research applications. In addition, the clinical US ([HI] model) system can be used as a suitable instrument for data acquisition and test the compatibility, efficacy, and validation at in vitro applications (BMF, flow phantom components). Wolters Kluwer - Medknow 2020-04-23 /pmc/articles/PMC7869744/ /pubmed/33659160 http://dx.doi.org/10.4103/JMU.JMU_116_19 Text en Copyright: © 2020 Journal of Medical Ultrasound http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Alshipli, Marwan Sayah, Mohannad Adel Oglat, Ammar A. Compatibility and Validation of a Recent Developed Artificial Blood through the Vascular Phantom Using Doppler Ultrasound Color- and Motion-mode Techniques |
title | Compatibility and Validation of a Recent Developed Artificial Blood through the Vascular Phantom Using Doppler Ultrasound Color- and Motion-mode Techniques |
title_full | Compatibility and Validation of a Recent Developed Artificial Blood through the Vascular Phantom Using Doppler Ultrasound Color- and Motion-mode Techniques |
title_fullStr | Compatibility and Validation of a Recent Developed Artificial Blood through the Vascular Phantom Using Doppler Ultrasound Color- and Motion-mode Techniques |
title_full_unstemmed | Compatibility and Validation of a Recent Developed Artificial Blood through the Vascular Phantom Using Doppler Ultrasound Color- and Motion-mode Techniques |
title_short | Compatibility and Validation of a Recent Developed Artificial Blood through the Vascular Phantom Using Doppler Ultrasound Color- and Motion-mode Techniques |
title_sort | compatibility and validation of a recent developed artificial blood through the vascular phantom using doppler ultrasound color- and motion-mode techniques |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7869744/ https://www.ncbi.nlm.nih.gov/pubmed/33659160 http://dx.doi.org/10.4103/JMU.JMU_116_19 |
work_keys_str_mv | AT alshiplimarwan compatibilityandvalidationofarecentdevelopedartificialbloodthroughthevascularphantomusingdopplerultrasoundcolorandmotionmodetechniques AT sayahmohannadadel compatibilityandvalidationofarecentdevelopedartificialbloodthroughthevascularphantomusingdopplerultrasoundcolorandmotionmodetechniques AT oglatammara compatibilityandvalidationofarecentdevelopedartificialbloodthroughthevascularphantomusingdopplerultrasoundcolorandmotionmodetechniques |