Cargando…

Compatibility and Validation of a Recent Developed Artificial Blood through the Vascular Phantom Using Doppler Ultrasound Color- and Motion-mode Techniques

BACKGROUND: Doppler technique is a technology that can raise the predictive, diagnostic, and monitoring abilities in blood flow and suitable for researchers. The application depends on Doppler shift (shift frequencies), wherein the movement of red blood cells away from the probe is determined by the...

Descripción completa

Detalles Bibliográficos
Autores principales: Alshipli, Marwan, Sayah, Mohannad Adel, Oglat, Ammar A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7869744/
https://www.ncbi.nlm.nih.gov/pubmed/33659160
http://dx.doi.org/10.4103/JMU.JMU_116_19
_version_ 1783648688094052352
author Alshipli, Marwan
Sayah, Mohannad Adel
Oglat, Ammar A.
author_facet Alshipli, Marwan
Sayah, Mohannad Adel
Oglat, Ammar A.
author_sort Alshipli, Marwan
collection PubMed
description BACKGROUND: Doppler technique is a technology that can raise the predictive, diagnostic, and monitoring abilities in blood flow and suitable for researchers. The application depends on Doppler shift (shift frequencies), wherein the movement of red blood cells away from the probe is determined by the decrease or increase in the ultrasound (US) frequency. METHODS: In this experiment, the clinical US (Hitachi Avious [HI] model) system was used as a primary instrument for data acquisition and test the compatibility, efficacy, and validation of artificial blood (blood-mimicking fluid [BMF]) by color- and motion-mode. This BMF was prepared for use in the Doppler flow phantom. RESULTS: The motion of BMF through the vessel-mimicking material (VMM) was parallel and the flow was laminar and in the straight form (regular flow of BMF inside the VMM). Moreover, the scale of color velocity in the normal range at that flow rate was in the normal range. CONCLUSION: The new BMF that is being valid and effective in utilizing for US in vitro research applications. In addition, the clinical US ([HI] model) system can be used as a suitable instrument for data acquisition and test the compatibility, efficacy, and validation at in vitro applications (BMF, flow phantom components).
format Online
Article
Text
id pubmed-7869744
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-78697442021-03-02 Compatibility and Validation of a Recent Developed Artificial Blood through the Vascular Phantom Using Doppler Ultrasound Color- and Motion-mode Techniques Alshipli, Marwan Sayah, Mohannad Adel Oglat, Ammar A. J Med Ultrasound Original Article BACKGROUND: Doppler technique is a technology that can raise the predictive, diagnostic, and monitoring abilities in blood flow and suitable for researchers. The application depends on Doppler shift (shift frequencies), wherein the movement of red blood cells away from the probe is determined by the decrease or increase in the ultrasound (US) frequency. METHODS: In this experiment, the clinical US (Hitachi Avious [HI] model) system was used as a primary instrument for data acquisition and test the compatibility, efficacy, and validation of artificial blood (blood-mimicking fluid [BMF]) by color- and motion-mode. This BMF was prepared for use in the Doppler flow phantom. RESULTS: The motion of BMF through the vessel-mimicking material (VMM) was parallel and the flow was laminar and in the straight form (regular flow of BMF inside the VMM). Moreover, the scale of color velocity in the normal range at that flow rate was in the normal range. CONCLUSION: The new BMF that is being valid and effective in utilizing for US in vitro research applications. In addition, the clinical US ([HI] model) system can be used as a suitable instrument for data acquisition and test the compatibility, efficacy, and validation at in vitro applications (BMF, flow phantom components). Wolters Kluwer - Medknow 2020-04-23 /pmc/articles/PMC7869744/ /pubmed/33659160 http://dx.doi.org/10.4103/JMU.JMU_116_19 Text en Copyright: © 2020 Journal of Medical Ultrasound http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Alshipli, Marwan
Sayah, Mohannad Adel
Oglat, Ammar A.
Compatibility and Validation of a Recent Developed Artificial Blood through the Vascular Phantom Using Doppler Ultrasound Color- and Motion-mode Techniques
title Compatibility and Validation of a Recent Developed Artificial Blood through the Vascular Phantom Using Doppler Ultrasound Color- and Motion-mode Techniques
title_full Compatibility and Validation of a Recent Developed Artificial Blood through the Vascular Phantom Using Doppler Ultrasound Color- and Motion-mode Techniques
title_fullStr Compatibility and Validation of a Recent Developed Artificial Blood through the Vascular Phantom Using Doppler Ultrasound Color- and Motion-mode Techniques
title_full_unstemmed Compatibility and Validation of a Recent Developed Artificial Blood through the Vascular Phantom Using Doppler Ultrasound Color- and Motion-mode Techniques
title_short Compatibility and Validation of a Recent Developed Artificial Blood through the Vascular Phantom Using Doppler Ultrasound Color- and Motion-mode Techniques
title_sort compatibility and validation of a recent developed artificial blood through the vascular phantom using doppler ultrasound color- and motion-mode techniques
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7869744/
https://www.ncbi.nlm.nih.gov/pubmed/33659160
http://dx.doi.org/10.4103/JMU.JMU_116_19
work_keys_str_mv AT alshiplimarwan compatibilityandvalidationofarecentdevelopedartificialbloodthroughthevascularphantomusingdopplerultrasoundcolorandmotionmodetechniques
AT sayahmohannadadel compatibilityandvalidationofarecentdevelopedartificialbloodthroughthevascularphantomusingdopplerultrasoundcolorandmotionmodetechniques
AT oglatammara compatibilityandvalidationofarecentdevelopedartificialbloodthroughthevascularphantomusingdopplerultrasoundcolorandmotionmodetechniques