Cargando…
The influence of sample geometry and size on porcine aortic material properties from uniaxial tensile tests using custom-designed tissue cutters, clamps and molds
The aim of this study was to identify the influence of specimen geometry and size on the results of aortic uniaxial tensile tests using custom-designed tissue cutters, clamps and molds. Six descending thoracic aortas from pigs were used for rectangular sample tests, in which the circumferential and...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7869995/ https://www.ncbi.nlm.nih.gov/pubmed/33556052 http://dx.doi.org/10.1371/journal.pone.0244390 |
_version_ | 1783648721932648448 |
---|---|
author | Pei, Ming Zou, Donghua Gao, Yong Zhang, Jianhua Huang, Ping Wang, Jiawen Huang, Jiang Li, Zhengdong Chen, Yijiu |
author_facet | Pei, Ming Zou, Donghua Gao, Yong Zhang, Jianhua Huang, Ping Wang, Jiawen Huang, Jiang Li, Zhengdong Chen, Yijiu |
author_sort | Pei, Ming |
collection | PubMed |
description | The aim of this study was to identify the influence of specimen geometry and size on the results of aortic uniaxial tensile tests using custom-designed tissue cutters, clamps and molds. Six descending thoracic aortas from pigs were used for rectangular sample tests, in which the circumferential and axial specimens had widths of 6 mm, 8 mm and 10 mm. The other six aortas were used for the dog-bone-shaped sample tests and were punched into circumferential, axial and oblique specimens with widths of 2 mm, 4 mm and 6 mm. We performed uniaxial tensile tests on the specimens and compared the test results. The results showed that mid-sample failure occurred in 85.2% of the dog-bone-shaped specimens and in 11.1% of the rectangular samples, which could be caused by Saint-Venant’s principle. Therefore, rectangular specimens were not suitable for aortic uniaxial tensile testing performed until rupture. The results also showed that the size effect of the aorta conformed to Weibull theory, and dog-bone-shaped specimens with a width of 4 mm were the optimal choice for aortic uniaxial tensile testing performed until rupture. |
format | Online Article Text |
id | pubmed-7869995 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-78699952021-02-11 The influence of sample geometry and size on porcine aortic material properties from uniaxial tensile tests using custom-designed tissue cutters, clamps and molds Pei, Ming Zou, Donghua Gao, Yong Zhang, Jianhua Huang, Ping Wang, Jiawen Huang, Jiang Li, Zhengdong Chen, Yijiu PLoS One Research Article The aim of this study was to identify the influence of specimen geometry and size on the results of aortic uniaxial tensile tests using custom-designed tissue cutters, clamps and molds. Six descending thoracic aortas from pigs were used for rectangular sample tests, in which the circumferential and axial specimens had widths of 6 mm, 8 mm and 10 mm. The other six aortas were used for the dog-bone-shaped sample tests and were punched into circumferential, axial and oblique specimens with widths of 2 mm, 4 mm and 6 mm. We performed uniaxial tensile tests on the specimens and compared the test results. The results showed that mid-sample failure occurred in 85.2% of the dog-bone-shaped specimens and in 11.1% of the rectangular samples, which could be caused by Saint-Venant’s principle. Therefore, rectangular specimens were not suitable for aortic uniaxial tensile testing performed until rupture. The results also showed that the size effect of the aorta conformed to Weibull theory, and dog-bone-shaped specimens with a width of 4 mm were the optimal choice for aortic uniaxial tensile testing performed until rupture. Public Library of Science 2021-02-08 /pmc/articles/PMC7869995/ /pubmed/33556052 http://dx.doi.org/10.1371/journal.pone.0244390 Text en © 2021 Pei et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Pei, Ming Zou, Donghua Gao, Yong Zhang, Jianhua Huang, Ping Wang, Jiawen Huang, Jiang Li, Zhengdong Chen, Yijiu The influence of sample geometry and size on porcine aortic material properties from uniaxial tensile tests using custom-designed tissue cutters, clamps and molds |
title | The influence of sample geometry and size on porcine aortic material properties from uniaxial tensile tests using custom-designed tissue cutters, clamps and molds |
title_full | The influence of sample geometry and size on porcine aortic material properties from uniaxial tensile tests using custom-designed tissue cutters, clamps and molds |
title_fullStr | The influence of sample geometry and size on porcine aortic material properties from uniaxial tensile tests using custom-designed tissue cutters, clamps and molds |
title_full_unstemmed | The influence of sample geometry and size on porcine aortic material properties from uniaxial tensile tests using custom-designed tissue cutters, clamps and molds |
title_short | The influence of sample geometry and size on porcine aortic material properties from uniaxial tensile tests using custom-designed tissue cutters, clamps and molds |
title_sort | influence of sample geometry and size on porcine aortic material properties from uniaxial tensile tests using custom-designed tissue cutters, clamps and molds |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7869995/ https://www.ncbi.nlm.nih.gov/pubmed/33556052 http://dx.doi.org/10.1371/journal.pone.0244390 |
work_keys_str_mv | AT peiming theinfluenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds AT zoudonghua theinfluenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds AT gaoyong theinfluenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds AT zhangjianhua theinfluenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds AT huangping theinfluenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds AT wangjiawen theinfluenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds AT huangjiang theinfluenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds AT lizhengdong theinfluenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds AT chenyijiu theinfluenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds AT peiming influenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds AT zoudonghua influenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds AT gaoyong influenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds AT zhangjianhua influenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds AT huangping influenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds AT wangjiawen influenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds AT huangjiang influenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds AT lizhengdong influenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds AT chenyijiu influenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds |