Cargando…

The influence of sample geometry and size on porcine aortic material properties from uniaxial tensile tests using custom-designed tissue cutters, clamps and molds

The aim of this study was to identify the influence of specimen geometry and size on the results of aortic uniaxial tensile tests using custom-designed tissue cutters, clamps and molds. Six descending thoracic aortas from pigs were used for rectangular sample tests, in which the circumferential and...

Descripción completa

Detalles Bibliográficos
Autores principales: Pei, Ming, Zou, Donghua, Gao, Yong, Zhang, Jianhua, Huang, Ping, Wang, Jiawen, Huang, Jiang, Li, Zhengdong, Chen, Yijiu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7869995/
https://www.ncbi.nlm.nih.gov/pubmed/33556052
http://dx.doi.org/10.1371/journal.pone.0244390
_version_ 1783648721932648448
author Pei, Ming
Zou, Donghua
Gao, Yong
Zhang, Jianhua
Huang, Ping
Wang, Jiawen
Huang, Jiang
Li, Zhengdong
Chen, Yijiu
author_facet Pei, Ming
Zou, Donghua
Gao, Yong
Zhang, Jianhua
Huang, Ping
Wang, Jiawen
Huang, Jiang
Li, Zhengdong
Chen, Yijiu
author_sort Pei, Ming
collection PubMed
description The aim of this study was to identify the influence of specimen geometry and size on the results of aortic uniaxial tensile tests using custom-designed tissue cutters, clamps and molds. Six descending thoracic aortas from pigs were used for rectangular sample tests, in which the circumferential and axial specimens had widths of 6 mm, 8 mm and 10 mm. The other six aortas were used for the dog-bone-shaped sample tests and were punched into circumferential, axial and oblique specimens with widths of 2 mm, 4 mm and 6 mm. We performed uniaxial tensile tests on the specimens and compared the test results. The results showed that mid-sample failure occurred in 85.2% of the dog-bone-shaped specimens and in 11.1% of the rectangular samples, which could be caused by Saint-Venant’s principle. Therefore, rectangular specimens were not suitable for aortic uniaxial tensile testing performed until rupture. The results also showed that the size effect of the aorta conformed to Weibull theory, and dog-bone-shaped specimens with a width of 4 mm were the optimal choice for aortic uniaxial tensile testing performed until rupture.
format Online
Article
Text
id pubmed-7869995
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-78699952021-02-11 The influence of sample geometry and size on porcine aortic material properties from uniaxial tensile tests using custom-designed tissue cutters, clamps and molds Pei, Ming Zou, Donghua Gao, Yong Zhang, Jianhua Huang, Ping Wang, Jiawen Huang, Jiang Li, Zhengdong Chen, Yijiu PLoS One Research Article The aim of this study was to identify the influence of specimen geometry and size on the results of aortic uniaxial tensile tests using custom-designed tissue cutters, clamps and molds. Six descending thoracic aortas from pigs were used for rectangular sample tests, in which the circumferential and axial specimens had widths of 6 mm, 8 mm and 10 mm. The other six aortas were used for the dog-bone-shaped sample tests and were punched into circumferential, axial and oblique specimens with widths of 2 mm, 4 mm and 6 mm. We performed uniaxial tensile tests on the specimens and compared the test results. The results showed that mid-sample failure occurred in 85.2% of the dog-bone-shaped specimens and in 11.1% of the rectangular samples, which could be caused by Saint-Venant’s principle. Therefore, rectangular specimens were not suitable for aortic uniaxial tensile testing performed until rupture. The results also showed that the size effect of the aorta conformed to Weibull theory, and dog-bone-shaped specimens with a width of 4 mm were the optimal choice for aortic uniaxial tensile testing performed until rupture. Public Library of Science 2021-02-08 /pmc/articles/PMC7869995/ /pubmed/33556052 http://dx.doi.org/10.1371/journal.pone.0244390 Text en © 2021 Pei et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Pei, Ming
Zou, Donghua
Gao, Yong
Zhang, Jianhua
Huang, Ping
Wang, Jiawen
Huang, Jiang
Li, Zhengdong
Chen, Yijiu
The influence of sample geometry and size on porcine aortic material properties from uniaxial tensile tests using custom-designed tissue cutters, clamps and molds
title The influence of sample geometry and size on porcine aortic material properties from uniaxial tensile tests using custom-designed tissue cutters, clamps and molds
title_full The influence of sample geometry and size on porcine aortic material properties from uniaxial tensile tests using custom-designed tissue cutters, clamps and molds
title_fullStr The influence of sample geometry and size on porcine aortic material properties from uniaxial tensile tests using custom-designed tissue cutters, clamps and molds
title_full_unstemmed The influence of sample geometry and size on porcine aortic material properties from uniaxial tensile tests using custom-designed tissue cutters, clamps and molds
title_short The influence of sample geometry and size on porcine aortic material properties from uniaxial tensile tests using custom-designed tissue cutters, clamps and molds
title_sort influence of sample geometry and size on porcine aortic material properties from uniaxial tensile tests using custom-designed tissue cutters, clamps and molds
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7869995/
https://www.ncbi.nlm.nih.gov/pubmed/33556052
http://dx.doi.org/10.1371/journal.pone.0244390
work_keys_str_mv AT peiming theinfluenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds
AT zoudonghua theinfluenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds
AT gaoyong theinfluenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds
AT zhangjianhua theinfluenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds
AT huangping theinfluenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds
AT wangjiawen theinfluenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds
AT huangjiang theinfluenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds
AT lizhengdong theinfluenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds
AT chenyijiu theinfluenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds
AT peiming influenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds
AT zoudonghua influenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds
AT gaoyong influenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds
AT zhangjianhua influenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds
AT huangping influenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds
AT wangjiawen influenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds
AT huangjiang influenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds
AT lizhengdong influenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds
AT chenyijiu influenceofsamplegeometryandsizeonporcineaorticmaterialpropertiesfromuniaxialtensiletestsusingcustomdesignedtissuecuttersclampsandmolds