Cargando…

Dosimetric Comparison of Helical Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy for Angiosarcoma of the Scalp

OBJECTIVE: We compared radiotherapy plans among helical tomotherapy (HT), volumetric-modulated arc therapy (VMAT), and intensity-modulated proton therapy (IMPT) for angiosarcoma of the scalp (AS). METHODS: We conducted a planning study for 19 patients with AS. The clinical target volume (CTV) 1 and...

Descripción completa

Detalles Bibliográficos
Autores principales: Mizuno, Tomoki, Tomita, Natsuo, Takaoka, Taiki, Tomida, Masashi, Fukuma, Hiroshi, Tsuchiya, Takahiro, Shibamoto, Yuta
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7871283/
https://www.ncbi.nlm.nih.gov/pubmed/33517860
http://dx.doi.org/10.1177/1533033820985866
_version_ 1783648976963108864
author Mizuno, Tomoki
Tomita, Natsuo
Takaoka, Taiki
Tomida, Masashi
Fukuma, Hiroshi
Tsuchiya, Takahiro
Shibamoto, Yuta
author_facet Mizuno, Tomoki
Tomita, Natsuo
Takaoka, Taiki
Tomida, Masashi
Fukuma, Hiroshi
Tsuchiya, Takahiro
Shibamoto, Yuta
author_sort Mizuno, Tomoki
collection PubMed
description OBJECTIVE: We compared radiotherapy plans among helical tomotherapy (HT), volumetric-modulated arc therapy (VMAT), and intensity-modulated proton therapy (IMPT) for angiosarcoma of the scalp (AS). METHODS: We conducted a planning study for 19 patients with AS. The clinical target volume (CTV) 1 and CTV2 were defined as the gross tumor volume with a specific margin and total scalp, respectively. For HT and VMAT, the planning target volume (PTV) 1 and PTV2 were defined as CTV1 and CTV2 with 0.5-cm margins, respectively. For IMPT, robust optimization was used instead of a CTV-PTV margin (i.e. CTV robust). The targets of the HT and VMAT plans were the PTV, whereas the IMPT plans targeted the CTV robust. In total, 70 Gy and 56 Gy were prescribed as the D95% (i.e. dose to 95% volume) of PTV1 (or CTV1 robust) and PTV2 (or CTV2 robust), respectively, using the simultaneous integrated boost (SIB) technique. Other constraint goals were also defined for the target and organs at risk (OAR). RESULTS: All dose constraint parameters for the target and OAR met the goals within the acceptable ranges for the 3 techniques. The coverage of the targets replaced by D95% and D98% were almost equivalent among the 3 techniques. The homogeneity index of PTV1 or CTV1 robust was equivalent among the 3 techniques, whereas that of PTV2 or CTV2 robust was significantly higher in the IMPT plans than in the other plans. IMPT reduced the Dmean of the brain and hippocampus by 49% to 95%, and the Dmax of the spinal cord, brainstem, and optic pathway by 70% to 92% compared with the other techniques. CONCLUSION: The 3 techniques with SIB methods provided sufficient coverage and satisfactory homogeneity for the targets, but IMPT achieved the best OAR sparing.
format Online
Article
Text
id pubmed-7871283
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-78712832021-02-19 Dosimetric Comparison of Helical Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy for Angiosarcoma of the Scalp Mizuno, Tomoki Tomita, Natsuo Takaoka, Taiki Tomida, Masashi Fukuma, Hiroshi Tsuchiya, Takahiro Shibamoto, Yuta Technol Cancer Res Treat Original Article OBJECTIVE: We compared radiotherapy plans among helical tomotherapy (HT), volumetric-modulated arc therapy (VMAT), and intensity-modulated proton therapy (IMPT) for angiosarcoma of the scalp (AS). METHODS: We conducted a planning study for 19 patients with AS. The clinical target volume (CTV) 1 and CTV2 were defined as the gross tumor volume with a specific margin and total scalp, respectively. For HT and VMAT, the planning target volume (PTV) 1 and PTV2 were defined as CTV1 and CTV2 with 0.5-cm margins, respectively. For IMPT, robust optimization was used instead of a CTV-PTV margin (i.e. CTV robust). The targets of the HT and VMAT plans were the PTV, whereas the IMPT plans targeted the CTV robust. In total, 70 Gy and 56 Gy were prescribed as the D95% (i.e. dose to 95% volume) of PTV1 (or CTV1 robust) and PTV2 (or CTV2 robust), respectively, using the simultaneous integrated boost (SIB) technique. Other constraint goals were also defined for the target and organs at risk (OAR). RESULTS: All dose constraint parameters for the target and OAR met the goals within the acceptable ranges for the 3 techniques. The coverage of the targets replaced by D95% and D98% were almost equivalent among the 3 techniques. The homogeneity index of PTV1 or CTV1 robust was equivalent among the 3 techniques, whereas that of PTV2 or CTV2 robust was significantly higher in the IMPT plans than in the other plans. IMPT reduced the Dmean of the brain and hippocampus by 49% to 95%, and the Dmax of the spinal cord, brainstem, and optic pathway by 70% to 92% compared with the other techniques. CONCLUSION: The 3 techniques with SIB methods provided sufficient coverage and satisfactory homogeneity for the targets, but IMPT achieved the best OAR sparing. SAGE Publications 2021-02-01 /pmc/articles/PMC7871283/ /pubmed/33517860 http://dx.doi.org/10.1177/1533033820985866 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Article
Mizuno, Tomoki
Tomita, Natsuo
Takaoka, Taiki
Tomida, Masashi
Fukuma, Hiroshi
Tsuchiya, Takahiro
Shibamoto, Yuta
Dosimetric Comparison of Helical Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy for Angiosarcoma of the Scalp
title Dosimetric Comparison of Helical Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy for Angiosarcoma of the Scalp
title_full Dosimetric Comparison of Helical Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy for Angiosarcoma of the Scalp
title_fullStr Dosimetric Comparison of Helical Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy for Angiosarcoma of the Scalp
title_full_unstemmed Dosimetric Comparison of Helical Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy for Angiosarcoma of the Scalp
title_short Dosimetric Comparison of Helical Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy for Angiosarcoma of the Scalp
title_sort dosimetric comparison of helical tomotherapy, volumetric-modulated arc therapy, and intensity-modulated proton therapy for angiosarcoma of the scalp
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7871283/
https://www.ncbi.nlm.nih.gov/pubmed/33517860
http://dx.doi.org/10.1177/1533033820985866
work_keys_str_mv AT mizunotomoki dosimetriccomparisonofhelicaltomotherapyvolumetricmodulatedarctherapyandintensitymodulatedprotontherapyforangiosarcomaofthescalp
AT tomitanatsuo dosimetriccomparisonofhelicaltomotherapyvolumetricmodulatedarctherapyandintensitymodulatedprotontherapyforangiosarcomaofthescalp
AT takaokataiki dosimetriccomparisonofhelicaltomotherapyvolumetricmodulatedarctherapyandintensitymodulatedprotontherapyforangiosarcomaofthescalp
AT tomidamasashi dosimetriccomparisonofhelicaltomotherapyvolumetricmodulatedarctherapyandintensitymodulatedprotontherapyforangiosarcomaofthescalp
AT fukumahiroshi dosimetriccomparisonofhelicaltomotherapyvolumetricmodulatedarctherapyandintensitymodulatedprotontherapyforangiosarcomaofthescalp
AT tsuchiyatakahiro dosimetriccomparisonofhelicaltomotherapyvolumetricmodulatedarctherapyandintensitymodulatedprotontherapyforangiosarcomaofthescalp
AT shibamotoyuta dosimetriccomparisonofhelicaltomotherapyvolumetricmodulatedarctherapyandintensitymodulatedprotontherapyforangiosarcomaofthescalp