Poly(4-amino-3-hydroxynaphthalene-1-sulfonic acid) modified glassy carbon electrode for square wave voltammetric determination of amoxicillin in four tablet brands

BACKGROUND: Amoxicillin (AMX), which is one of the β-lactam antibiotics used in the treatment of bacterial infections, is known to have a serious mechanism of resistance necessitating continuous monitoring of its level in pharmaceutical and serum samples. RESULTS: In this study, we presented selecti...

Descripción completa

Detalles Bibliográficos
Autores principales: Kassa, Adane, Amare, Meareg
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7871396/
https://www.ncbi.nlm.nih.gov/pubmed/33557918
http://dx.doi.org/10.1186/s13065-021-00739-0
_version_ 1783649000486862848
author Kassa, Adane
Amare, Meareg
author_facet Kassa, Adane
Amare, Meareg
author_sort Kassa, Adane
collection PubMed
description BACKGROUND: Amoxicillin (AMX), which is one of the β-lactam antibiotics used in the treatment of bacterial infections, is known to have a serious mechanism of resistance necessitating continuous monitoring of its level in pharmaceutical and serum samples. RESULTS: In this study, we presented selective, accurate, and precise square wave voltammetric method based on poly(4-amino-3-hydroxynaphthalene-1-sulfonic acid) modified glassy carbon electrode (poly(AHNSA/GCE)) for determination of amoxicillin in four selected tablet brands. Appearance of a peak in the oxidative scan direction without a peak in the reductive direction of cyclic voltammograms of both bare GCE and poly(AHNSA/GCE) with four folds current and much reduced potential on the modified electrode showed catalytic property of the modifier towards oxidation of AMX. While cyclic voltammetric studies of effect of scan rate showed predominantly diffusion controlled oxidation of AMX with one electron participation, effect of pH revealed participation of protons and electrons in a 1:1 ratio. The square wave voltammetric peak current response of the modified electrode for AMX showed linear dependence on the concentration of the spiked standard AMX in the range 10–150 µmol L(−1) with 9.9 nmol L(−1) LOD. The AMX content of the studied tablet brands were found in the range 97.84–100.78% of the labeled value. Spike recovery results of 99.6–100.5%, and interference recovery results of 95.4–100.8% AMX in the presence of 50–200% of ampicillin and cloxicillin validated the applicability of the method for determination of amoxicillin in tablet formulation. CONCLUSION: In contrast to the previously reported works on determination of amoxicillin, the present method showed an excellent performance making it a potential method for determination of amoxicillin in real samples including serum samples.
format Online
Article
Text
id pubmed-7871396
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-78713962021-02-09 Poly(4-amino-3-hydroxynaphthalene-1-sulfonic acid) modified glassy carbon electrode for square wave voltammetric determination of amoxicillin in four tablet brands Kassa, Adane Amare, Meareg BMC Chem Research Article BACKGROUND: Amoxicillin (AMX), which is one of the β-lactam antibiotics used in the treatment of bacterial infections, is known to have a serious mechanism of resistance necessitating continuous monitoring of its level in pharmaceutical and serum samples. RESULTS: In this study, we presented selective, accurate, and precise square wave voltammetric method based on poly(4-amino-3-hydroxynaphthalene-1-sulfonic acid) modified glassy carbon electrode (poly(AHNSA/GCE)) for determination of amoxicillin in four selected tablet brands. Appearance of a peak in the oxidative scan direction without a peak in the reductive direction of cyclic voltammograms of both bare GCE and poly(AHNSA/GCE) with four folds current and much reduced potential on the modified electrode showed catalytic property of the modifier towards oxidation of AMX. While cyclic voltammetric studies of effect of scan rate showed predominantly diffusion controlled oxidation of AMX with one electron participation, effect of pH revealed participation of protons and electrons in a 1:1 ratio. The square wave voltammetric peak current response of the modified electrode for AMX showed linear dependence on the concentration of the spiked standard AMX in the range 10–150 µmol L(−1) with 9.9 nmol L(−1) LOD. The AMX content of the studied tablet brands were found in the range 97.84–100.78% of the labeled value. Spike recovery results of 99.6–100.5%, and interference recovery results of 95.4–100.8% AMX in the presence of 50–200% of ampicillin and cloxicillin validated the applicability of the method for determination of amoxicillin in tablet formulation. CONCLUSION: In contrast to the previously reported works on determination of amoxicillin, the present method showed an excellent performance making it a potential method for determination of amoxicillin in real samples including serum samples. Springer International Publishing 2021-02-08 /pmc/articles/PMC7871396/ /pubmed/33557918 http://dx.doi.org/10.1186/s13065-021-00739-0 Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Kassa, Adane
Amare, Meareg
Poly(4-amino-3-hydroxynaphthalene-1-sulfonic acid) modified glassy carbon electrode for square wave voltammetric determination of amoxicillin in four tablet brands
title Poly(4-amino-3-hydroxynaphthalene-1-sulfonic acid) modified glassy carbon electrode for square wave voltammetric determination of amoxicillin in four tablet brands
title_full Poly(4-amino-3-hydroxynaphthalene-1-sulfonic acid) modified glassy carbon electrode for square wave voltammetric determination of amoxicillin in four tablet brands
title_fullStr Poly(4-amino-3-hydroxynaphthalene-1-sulfonic acid) modified glassy carbon electrode for square wave voltammetric determination of amoxicillin in four tablet brands
title_full_unstemmed Poly(4-amino-3-hydroxynaphthalene-1-sulfonic acid) modified glassy carbon electrode for square wave voltammetric determination of amoxicillin in four tablet brands
title_short Poly(4-amino-3-hydroxynaphthalene-1-sulfonic acid) modified glassy carbon electrode for square wave voltammetric determination of amoxicillin in four tablet brands
title_sort poly(4-amino-3-hydroxynaphthalene-1-sulfonic acid) modified glassy carbon electrode for square wave voltammetric determination of amoxicillin in four tablet brands
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7871396/
https://www.ncbi.nlm.nih.gov/pubmed/33557918
http://dx.doi.org/10.1186/s13065-021-00739-0
work_keys_str_mv AT kassaadane poly4amino3hydroxynaphthalene1sulfonicacidmodifiedglassycarbonelectrodeforsquarewavevoltammetricdeterminationofamoxicillininfourtabletbrands
AT amaremeareg poly4amino3hydroxynaphthalene1sulfonicacidmodifiedglassycarbonelectrodeforsquarewavevoltammetricdeterminationofamoxicillininfourtabletbrands