Evaluation of three extraction-free SARS-CoV-2 RT-PCR assays: A feasible alternative approach with low technical requirements
The worldwide demand for SARS-CoV-2 RT-PCR testing resulted in a shortage of diagnostic kits. RNA extraction step constitutes a major bottleneck to perform diagnostic. The aim of this study was to assess performances of different extraction-free SARS-CoV-2 RT-PCR assays compared to a reference RT-PC...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier B.V.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7871772/ https://www.ncbi.nlm.nih.gov/pubmed/33577957 http://dx.doi.org/10.1016/j.jviromet.2021.114086 |
_version_ | 1783649074536251392 |
---|---|
author | Visseaux, Benoit Collin, Gilles Houhou-Fidouh, Nadhira Le Hingrat, Quentin Ferré, Valentine Marie Damond, Florence Ichou, Houria Descamps, Diane Charpentier, Charlotte |
author_facet | Visseaux, Benoit Collin, Gilles Houhou-Fidouh, Nadhira Le Hingrat, Quentin Ferré, Valentine Marie Damond, Florence Ichou, Houria Descamps, Diane Charpentier, Charlotte |
author_sort | Visseaux, Benoit |
collection | PubMed |
description | The worldwide demand for SARS-CoV-2 RT-PCR testing resulted in a shortage of diagnostic kits. RNA extraction step constitutes a major bottleneck to perform diagnostic. The aim of this study was to assess performances of different extraction-free SARS-CoV-2 RT-PCR assays compared to a reference RT-PCR assay. The panel of evaluation consisted of 94 samples: 69 positive and 25 negative for SARS-CoV-2 by reference RT-PCR. Three extraction-free RT-PCR assays were assessed: (i) PrimeDirect® Probe RT-qPCR Mix (Takara), (ii) PrimeScript®RT-PCR (Takara), and (iii) SARS-CoV-2 SANSURE®BIOTECH Novel Coronavirus (Sansure). The overall sensitivity of PrimeDirect, PrimeScript and Sansure assays was 55.1 %, 69.6 % and 69.6 %, respectively. The sensitivity increased among samples with Ct<30: 91.9 % (n = 34/37), 89.2 % (n = 33/37) and 94.6 % (n = 35/37) for PrimeDirect, PrimeScript and Sansure assays, respectively. The specificity was 88 %, 100 % and 100 % for PrimeDirect, PrimeScript and Sansure assays, respectively. In the present study, we showed a good sensitivity of extraction-free PCR assays, especially for high viral loads (Ct<30), except PrimeDirect that displayed imperfect sensitivity and specificity. Despite a lower sensitivity for low viral loads, extraction-free reagents can provide a valuable option, cheaper, easier and less reagent consuming for SARS-CoV-2 diagnostic, especially in laboratory with lower experience and equipment for molecular assays. |
format | Online Article Text |
id | pubmed-7871772 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier B.V. |
record_format | MEDLINE/PubMed |
spelling | pubmed-78717722021-02-10 Evaluation of three extraction-free SARS-CoV-2 RT-PCR assays: A feasible alternative approach with low technical requirements Visseaux, Benoit Collin, Gilles Houhou-Fidouh, Nadhira Le Hingrat, Quentin Ferré, Valentine Marie Damond, Florence Ichou, Houria Descamps, Diane Charpentier, Charlotte J Virol Methods Article The worldwide demand for SARS-CoV-2 RT-PCR testing resulted in a shortage of diagnostic kits. RNA extraction step constitutes a major bottleneck to perform diagnostic. The aim of this study was to assess performances of different extraction-free SARS-CoV-2 RT-PCR assays compared to a reference RT-PCR assay. The panel of evaluation consisted of 94 samples: 69 positive and 25 negative for SARS-CoV-2 by reference RT-PCR. Three extraction-free RT-PCR assays were assessed: (i) PrimeDirect® Probe RT-qPCR Mix (Takara), (ii) PrimeScript®RT-PCR (Takara), and (iii) SARS-CoV-2 SANSURE®BIOTECH Novel Coronavirus (Sansure). The overall sensitivity of PrimeDirect, PrimeScript and Sansure assays was 55.1 %, 69.6 % and 69.6 %, respectively. The sensitivity increased among samples with Ct<30: 91.9 % (n = 34/37), 89.2 % (n = 33/37) and 94.6 % (n = 35/37) for PrimeDirect, PrimeScript and Sansure assays, respectively. The specificity was 88 %, 100 % and 100 % for PrimeDirect, PrimeScript and Sansure assays, respectively. In the present study, we showed a good sensitivity of extraction-free PCR assays, especially for high viral loads (Ct<30), except PrimeDirect that displayed imperfect sensitivity and specificity. Despite a lower sensitivity for low viral loads, extraction-free reagents can provide a valuable option, cheaper, easier and less reagent consuming for SARS-CoV-2 diagnostic, especially in laboratory with lower experience and equipment for molecular assays. Elsevier B.V. 2021-05 2021-02-09 /pmc/articles/PMC7871772/ /pubmed/33577957 http://dx.doi.org/10.1016/j.jviromet.2021.114086 Text en © 2021 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Article Visseaux, Benoit Collin, Gilles Houhou-Fidouh, Nadhira Le Hingrat, Quentin Ferré, Valentine Marie Damond, Florence Ichou, Houria Descamps, Diane Charpentier, Charlotte Evaluation of three extraction-free SARS-CoV-2 RT-PCR assays: A feasible alternative approach with low technical requirements |
title | Evaluation of three extraction-free SARS-CoV-2 RT-PCR assays: A feasible alternative approach with low technical requirements |
title_full | Evaluation of three extraction-free SARS-CoV-2 RT-PCR assays: A feasible alternative approach with low technical requirements |
title_fullStr | Evaluation of three extraction-free SARS-CoV-2 RT-PCR assays: A feasible alternative approach with low technical requirements |
title_full_unstemmed | Evaluation of three extraction-free SARS-CoV-2 RT-PCR assays: A feasible alternative approach with low technical requirements |
title_short | Evaluation of three extraction-free SARS-CoV-2 RT-PCR assays: A feasible alternative approach with low technical requirements |
title_sort | evaluation of three extraction-free sars-cov-2 rt-pcr assays: a feasible alternative approach with low technical requirements |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7871772/ https://www.ncbi.nlm.nih.gov/pubmed/33577957 http://dx.doi.org/10.1016/j.jviromet.2021.114086 |
work_keys_str_mv | AT visseauxbenoit evaluationofthreeextractionfreesarscov2rtpcrassaysafeasiblealternativeapproachwithlowtechnicalrequirements AT collingilles evaluationofthreeextractionfreesarscov2rtpcrassaysafeasiblealternativeapproachwithlowtechnicalrequirements AT houhoufidouhnadhira evaluationofthreeextractionfreesarscov2rtpcrassaysafeasiblealternativeapproachwithlowtechnicalrequirements AT lehingratquentin evaluationofthreeextractionfreesarscov2rtpcrassaysafeasiblealternativeapproachwithlowtechnicalrequirements AT ferrevalentinemarie evaluationofthreeextractionfreesarscov2rtpcrassaysafeasiblealternativeapproachwithlowtechnicalrequirements AT damondflorence evaluationofthreeextractionfreesarscov2rtpcrassaysafeasiblealternativeapproachwithlowtechnicalrequirements AT ichouhouria evaluationofthreeextractionfreesarscov2rtpcrassaysafeasiblealternativeapproachwithlowtechnicalrequirements AT descampsdiane evaluationofthreeextractionfreesarscov2rtpcrassaysafeasiblealternativeapproachwithlowtechnicalrequirements AT charpentiercharlotte evaluationofthreeextractionfreesarscov2rtpcrassaysafeasiblealternativeapproachwithlowtechnicalrequirements |