Cargando…

Peripheral Anterior Chamber Depth and Angle Measurements Using Pentacam After Implantation of Toric and Non-toric Implantable Collamer Lenses

Purpose: To evaluate the characteristics of peripheral anterior chamber measurements by Pentacam after posterior implantable collamer lenses (ICL) and toric ICL (TICL) with central hole (V4c) implantation. Methods: Prospective, non-randomized consecutive case series. Forty-six patients undergoing IC...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Jiao, Zhao, Jing, Yang, Wen, Miao, Huamao, Niu, Lingling, Shang, Jianmin, Wang, Xiaoying, Zhou, Xingtao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7873523/
https://www.ncbi.nlm.nih.gov/pubmed/33585524
http://dx.doi.org/10.3389/fmed.2021.610590
_version_ 1783649404667822080
author Zhao, Jiao
Zhao, Jing
Yang, Wen
Miao, Huamao
Niu, Lingling
Shang, Jianmin
Wang, Xiaoying
Zhou, Xingtao
author_facet Zhao, Jiao
Zhao, Jing
Yang, Wen
Miao, Huamao
Niu, Lingling
Shang, Jianmin
Wang, Xiaoying
Zhou, Xingtao
author_sort Zhao, Jiao
collection PubMed
description Purpose: To evaluate the characteristics of peripheral anterior chamber measurements by Pentacam after posterior implantable collamer lenses (ICL) and toric ICL (TICL) with central hole (V4c) implantation. Methods: Prospective, non-randomized consecutive case series. Forty-six patients undergoing ICL implantation in one eye (Group A) and identically sized TICL in the contralateral eye (Group B) in the Refractive Surgery Center of Eye and ENT Hospital of Fudan University were prospectively included. According to ICL/TICL size, these eyes were further divided into four subgroups. Peripheral anterior chamber depth (PACD) and angle (ACA) in nasal and temporal sides were measured using Pentacam pre-operatively and 12-month post-operatively. Results: The safety indices were 1.34 ± 0.32 and 1.25 ± 0.16 and the efficacy indices were 1.20 ± 0.24 and 1.19 ± 0.19 for ICL and TICL groups, respectively. There was no significant difference in pre-operative PACD or ACA between the two groups. Post-operative PACD and ACA were significantly lower than pre-operative values. Variations of PACD and ACA of TICL group were significantly larger than those of ICL group. The change of ACA for 13.2 mm lenses was significantly larger than that of 12.6 mm lenses. Pre-operative CACD and vault were significantly associated with post-operative PACD, while pre-operative ACA and vault were significantly associated with post-operative ACA. Conclusions: Variations of PACD and ACA were greater in eyes after TICL (V4c) implantation compared with identically sized ICL (V4c) implantation and with larger size than smaller size lens implantation. Pre-operative anterior chamber structure and vault affect post-operative PACD and ACA.
format Online
Article
Text
id pubmed-7873523
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-78735232021-02-11 Peripheral Anterior Chamber Depth and Angle Measurements Using Pentacam After Implantation of Toric and Non-toric Implantable Collamer Lenses Zhao, Jiao Zhao, Jing Yang, Wen Miao, Huamao Niu, Lingling Shang, Jianmin Wang, Xiaoying Zhou, Xingtao Front Med (Lausanne) Medicine Purpose: To evaluate the characteristics of peripheral anterior chamber measurements by Pentacam after posterior implantable collamer lenses (ICL) and toric ICL (TICL) with central hole (V4c) implantation. Methods: Prospective, non-randomized consecutive case series. Forty-six patients undergoing ICL implantation in one eye (Group A) and identically sized TICL in the contralateral eye (Group B) in the Refractive Surgery Center of Eye and ENT Hospital of Fudan University were prospectively included. According to ICL/TICL size, these eyes were further divided into four subgroups. Peripheral anterior chamber depth (PACD) and angle (ACA) in nasal and temporal sides were measured using Pentacam pre-operatively and 12-month post-operatively. Results: The safety indices were 1.34 ± 0.32 and 1.25 ± 0.16 and the efficacy indices were 1.20 ± 0.24 and 1.19 ± 0.19 for ICL and TICL groups, respectively. There was no significant difference in pre-operative PACD or ACA between the two groups. Post-operative PACD and ACA were significantly lower than pre-operative values. Variations of PACD and ACA of TICL group were significantly larger than those of ICL group. The change of ACA for 13.2 mm lenses was significantly larger than that of 12.6 mm lenses. Pre-operative CACD and vault were significantly associated with post-operative PACD, while pre-operative ACA and vault were significantly associated with post-operative ACA. Conclusions: Variations of PACD and ACA were greater in eyes after TICL (V4c) implantation compared with identically sized ICL (V4c) implantation and with larger size than smaller size lens implantation. Pre-operative anterior chamber structure and vault affect post-operative PACD and ACA. Frontiers Media S.A. 2021-01-27 /pmc/articles/PMC7873523/ /pubmed/33585524 http://dx.doi.org/10.3389/fmed.2021.610590 Text en Copyright © 2021 Zhao, Zhao, Yang, Miao, Niu, Shang, Wang and Zhou. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Medicine
Zhao, Jiao
Zhao, Jing
Yang, Wen
Miao, Huamao
Niu, Lingling
Shang, Jianmin
Wang, Xiaoying
Zhou, Xingtao
Peripheral Anterior Chamber Depth and Angle Measurements Using Pentacam After Implantation of Toric and Non-toric Implantable Collamer Lenses
title Peripheral Anterior Chamber Depth and Angle Measurements Using Pentacam After Implantation of Toric and Non-toric Implantable Collamer Lenses
title_full Peripheral Anterior Chamber Depth and Angle Measurements Using Pentacam After Implantation of Toric and Non-toric Implantable Collamer Lenses
title_fullStr Peripheral Anterior Chamber Depth and Angle Measurements Using Pentacam After Implantation of Toric and Non-toric Implantable Collamer Lenses
title_full_unstemmed Peripheral Anterior Chamber Depth and Angle Measurements Using Pentacam After Implantation of Toric and Non-toric Implantable Collamer Lenses
title_short Peripheral Anterior Chamber Depth and Angle Measurements Using Pentacam After Implantation of Toric and Non-toric Implantable Collamer Lenses
title_sort peripheral anterior chamber depth and angle measurements using pentacam after implantation of toric and non-toric implantable collamer lenses
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7873523/
https://www.ncbi.nlm.nih.gov/pubmed/33585524
http://dx.doi.org/10.3389/fmed.2021.610590
work_keys_str_mv AT zhaojiao peripheralanteriorchamberdepthandanglemeasurementsusingpentacamafterimplantationoftoricandnontoricimplantablecollamerlenses
AT zhaojing peripheralanteriorchamberdepthandanglemeasurementsusingpentacamafterimplantationoftoricandnontoricimplantablecollamerlenses
AT yangwen peripheralanteriorchamberdepthandanglemeasurementsusingpentacamafterimplantationoftoricandnontoricimplantablecollamerlenses
AT miaohuamao peripheralanteriorchamberdepthandanglemeasurementsusingpentacamafterimplantationoftoricandnontoricimplantablecollamerlenses
AT niulingling peripheralanteriorchamberdepthandanglemeasurementsusingpentacamafterimplantationoftoricandnontoricimplantablecollamerlenses
AT shangjianmin peripheralanteriorchamberdepthandanglemeasurementsusingpentacamafterimplantationoftoricandnontoricimplantablecollamerlenses
AT wangxiaoying peripheralanteriorchamberdepthandanglemeasurementsusingpentacamafterimplantationoftoricandnontoricimplantablecollamerlenses
AT zhouxingtao peripheralanteriorchamberdepthandanglemeasurementsusingpentacamafterimplantationoftoricandnontoricimplantablecollamerlenses