Cargando…

Electromyogram (EMG) Removal by Adding Sources of EMG (ERASE)—A Novel ICA-Based Algorithm for Removing Myoelectric Artifacts From EEG

Electroencephalographic (EEG) recordings are often contaminated by electromyographic (EMG) artifacts, especially when recording during movement. Existing methods to remove EMG artifacts include independent component analysis (ICA), and other high-order statistical methods. However, these methods can...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Yongcheng, Wang, Po T., Vaidya, Mukta P., Flint, Robert D., Liu, Charles Y., Slutzky, Marc W., Do, An H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7873899/
https://www.ncbi.nlm.nih.gov/pubmed/33584176
http://dx.doi.org/10.3389/fnins.2020.597941
_version_ 1783649472079724544
author Li, Yongcheng
Wang, Po T.
Vaidya, Mukta P.
Flint, Robert D.
Liu, Charles Y.
Slutzky, Marc W.
Do, An H.
author_facet Li, Yongcheng
Wang, Po T.
Vaidya, Mukta P.
Flint, Robert D.
Liu, Charles Y.
Slutzky, Marc W.
Do, An H.
author_sort Li, Yongcheng
collection PubMed
description Electroencephalographic (EEG) recordings are often contaminated by electromyographic (EMG) artifacts, especially when recording during movement. Existing methods to remove EMG artifacts include independent component analysis (ICA), and other high-order statistical methods. However, these methods can not effectively remove most of EMG artifacts. Here, we proposed a modified ICA model for EMG artifacts removal in the EEG, which is called EMG Removal by Adding Sources of EMG (ERASE). In this new approach, additional channels of real EMG from neck and head muscles (reference artifacts) were added as inputs to ICA in order to “force” the most power from EMG artifacts into a few independent components (ICs). The ICs containing EMG artifacts (the “artifact ICs”) were identified and rejected using an automated procedure. ERASE was validated first using both simulated and experimentally-recorded EEG and EMG. Simulation results showed ERASE removed EMG artifacts from EEG significantly more effectively than conventional ICA. Also, it had a low false positive rate and high sensitivity. Subsequently, EEG was collected from 8 healthy participants while they moved their hands to test the realistic efficacy of this approach. Results showed that ERASE successfully removed EMG artifacts (on average, about 75% of EMG artifacts were removed when using real EMGs as reference artifacts) while preserving the expected EEG features related to movement. We also tested the ERASE procedure using simulated EMGs as reference artifacts (about 63% of EMG artifacts removed). Compared to conventional ICA, ERASE removed on average 26% more EMG artifacts from EEG. These findings suggest that ERASE can achieve significant separation of EEG signal and EMG artifacts without a loss of the underlying EEG features. These results indicate that using additional real or simulated EMG sources can increase the effectiveness of ICA in removing EMG artifacts from EEG. Combined with automated artifact IC rejection, ERASE also minimizes potential user bias. Future work will focus on improving ERASE so that it can also be used in real-time applications.
format Online
Article
Text
id pubmed-7873899
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-78738992021-02-11 Electromyogram (EMG) Removal by Adding Sources of EMG (ERASE)—A Novel ICA-Based Algorithm for Removing Myoelectric Artifacts From EEG Li, Yongcheng Wang, Po T. Vaidya, Mukta P. Flint, Robert D. Liu, Charles Y. Slutzky, Marc W. Do, An H. Front Neurosci Neuroscience Electroencephalographic (EEG) recordings are often contaminated by electromyographic (EMG) artifacts, especially when recording during movement. Existing methods to remove EMG artifacts include independent component analysis (ICA), and other high-order statistical methods. However, these methods can not effectively remove most of EMG artifacts. Here, we proposed a modified ICA model for EMG artifacts removal in the EEG, which is called EMG Removal by Adding Sources of EMG (ERASE). In this new approach, additional channels of real EMG from neck and head muscles (reference artifacts) were added as inputs to ICA in order to “force” the most power from EMG artifacts into a few independent components (ICs). The ICs containing EMG artifacts (the “artifact ICs”) were identified and rejected using an automated procedure. ERASE was validated first using both simulated and experimentally-recorded EEG and EMG. Simulation results showed ERASE removed EMG artifacts from EEG significantly more effectively than conventional ICA. Also, it had a low false positive rate and high sensitivity. Subsequently, EEG was collected from 8 healthy participants while they moved their hands to test the realistic efficacy of this approach. Results showed that ERASE successfully removed EMG artifacts (on average, about 75% of EMG artifacts were removed when using real EMGs as reference artifacts) while preserving the expected EEG features related to movement. We also tested the ERASE procedure using simulated EMGs as reference artifacts (about 63% of EMG artifacts removed). Compared to conventional ICA, ERASE removed on average 26% more EMG artifacts from EEG. These findings suggest that ERASE can achieve significant separation of EEG signal and EMG artifacts without a loss of the underlying EEG features. These results indicate that using additional real or simulated EMG sources can increase the effectiveness of ICA in removing EMG artifacts from EEG. Combined with automated artifact IC rejection, ERASE also minimizes potential user bias. Future work will focus on improving ERASE so that it can also be used in real-time applications. Frontiers Media S.A. 2021-01-15 /pmc/articles/PMC7873899/ /pubmed/33584176 http://dx.doi.org/10.3389/fnins.2020.597941 Text en Copyright © 2021 Li, Wang, Vaidya, Flint, Liu, Slutzky and Do. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Li, Yongcheng
Wang, Po T.
Vaidya, Mukta P.
Flint, Robert D.
Liu, Charles Y.
Slutzky, Marc W.
Do, An H.
Electromyogram (EMG) Removal by Adding Sources of EMG (ERASE)—A Novel ICA-Based Algorithm for Removing Myoelectric Artifacts From EEG
title Electromyogram (EMG) Removal by Adding Sources of EMG (ERASE)—A Novel ICA-Based Algorithm for Removing Myoelectric Artifacts From EEG
title_full Electromyogram (EMG) Removal by Adding Sources of EMG (ERASE)—A Novel ICA-Based Algorithm for Removing Myoelectric Artifacts From EEG
title_fullStr Electromyogram (EMG) Removal by Adding Sources of EMG (ERASE)—A Novel ICA-Based Algorithm for Removing Myoelectric Artifacts From EEG
title_full_unstemmed Electromyogram (EMG) Removal by Adding Sources of EMG (ERASE)—A Novel ICA-Based Algorithm for Removing Myoelectric Artifacts From EEG
title_short Electromyogram (EMG) Removal by Adding Sources of EMG (ERASE)—A Novel ICA-Based Algorithm for Removing Myoelectric Artifacts From EEG
title_sort electromyogram (emg) removal by adding sources of emg (erase)—a novel ica-based algorithm for removing myoelectric artifacts from eeg
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7873899/
https://www.ncbi.nlm.nih.gov/pubmed/33584176
http://dx.doi.org/10.3389/fnins.2020.597941
work_keys_str_mv AT liyongcheng electromyogramemgremovalbyaddingsourcesofemgeraseanovelicabasedalgorithmforremovingmyoelectricartifactsfromeeg
AT wangpot electromyogramemgremovalbyaddingsourcesofemgeraseanovelicabasedalgorithmforremovingmyoelectricartifactsfromeeg
AT vaidyamuktap electromyogramemgremovalbyaddingsourcesofemgeraseanovelicabasedalgorithmforremovingmyoelectricartifactsfromeeg
AT flintrobertd electromyogramemgremovalbyaddingsourcesofemgeraseanovelicabasedalgorithmforremovingmyoelectricartifactsfromeeg
AT liucharlesy electromyogramemgremovalbyaddingsourcesofemgeraseanovelicabasedalgorithmforremovingmyoelectricartifactsfromeeg
AT slutzkymarcw electromyogramemgremovalbyaddingsourcesofemgeraseanovelicabasedalgorithmforremovingmyoelectricartifactsfromeeg
AT doanh electromyogramemgremovalbyaddingsourcesofemgeraseanovelicabasedalgorithmforremovingmyoelectricartifactsfromeeg