Monte Carlo simulation and performance assessment of GE Discovery 690 VCT positron emission tomography/computed tomography scanner

The aim of this study is to simulate GE Discovery 690 VCT positron emission tomography/computed tomography (PET/CT) scanner using Geant4 Application for Tomographic Emission (GATE) simulation package (version 8). Then, we assess the performance of scanner by comparing measured and simulated paramete...

Descripción completa

Detalles Bibliográficos
Autores principales: Kashian, Elham, Ahangari, Hadi Taleshi, Dehlaghi, Vahab, Khoshgard, Karim, Ghafarian, Pardis, Ghorbani, Raheb
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7875045/
https://www.ncbi.nlm.nih.gov/pubmed/33623506
http://dx.doi.org/10.4103/wjnm.WJNM_4_20
_version_ 1783649712447946752
author Kashian, Elham
Ahangari, Hadi Taleshi
Dehlaghi, Vahab
Khoshgard, Karim
Ghafarian, Pardis
Ghorbani, Raheb
author_facet Kashian, Elham
Ahangari, Hadi Taleshi
Dehlaghi, Vahab
Khoshgard, Karim
Ghafarian, Pardis
Ghorbani, Raheb
author_sort Kashian, Elham
collection PubMed
description The aim of this study is to simulate GE Discovery 690 VCT positron emission tomography/computed tomography (PET/CT) scanner using Geant4 Application for Tomographic Emission (GATE) simulation package (version 8). Then, we assess the performance of scanner by comparing measured and simulated parameter results. Detection system and geometry of PET scanner that consists of 13,824 LYSO crystals designed in 256 blocks and 24 ring detectors were modeled. In order to achieve a precise model, we verified scanner model. Validation was based on a comparison between simulation data and experimental results obtained with this scanner in the same situation. Parameters used for validation were sensitivity, spatial resolution, and contrast. Image quality assessment was done based on comparing the contrast recovery coefficient (CRC) of simulated and measured images. The findings demonstrate that the mean difference between simulated and measured sensitivity is <7%. The simulated spatial resolution agreed to within <5.5% of the measured values. Contrast results had a slight divergence within the range below 4%. The image quality validation study demonstrated an acceptable agreement in CRC for 8:1 and 2:1 source-to-background activity ratio. Validated performance parameters showed good agreement between experimental data and simulated results and demonstrated that GATE is a valid simulation tool for simulating this scanner model. The simulated model of this scanner can be used for future studies regarding optimization of image reconstruction algorithms and emission acquisition protocols.
format Online
Article
Text
id pubmed-7875045
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-78750452021-02-22 Monte Carlo simulation and performance assessment of GE Discovery 690 VCT positron emission tomography/computed tomography scanner Kashian, Elham Ahangari, Hadi Taleshi Dehlaghi, Vahab Khoshgard, Karim Ghafarian, Pardis Ghorbani, Raheb World J Nucl Med Original Article The aim of this study is to simulate GE Discovery 690 VCT positron emission tomography/computed tomography (PET/CT) scanner using Geant4 Application for Tomographic Emission (GATE) simulation package (version 8). Then, we assess the performance of scanner by comparing measured and simulated parameter results. Detection system and geometry of PET scanner that consists of 13,824 LYSO crystals designed in 256 blocks and 24 ring detectors were modeled. In order to achieve a precise model, we verified scanner model. Validation was based on a comparison between simulation data and experimental results obtained with this scanner in the same situation. Parameters used for validation were sensitivity, spatial resolution, and contrast. Image quality assessment was done based on comparing the contrast recovery coefficient (CRC) of simulated and measured images. The findings demonstrate that the mean difference between simulated and measured sensitivity is <7%. The simulated spatial resolution agreed to within <5.5% of the measured values. Contrast results had a slight divergence within the range below 4%. The image quality validation study demonstrated an acceptable agreement in CRC for 8:1 and 2:1 source-to-background activity ratio. Validated performance parameters showed good agreement between experimental data and simulated results and demonstrated that GATE is a valid simulation tool for simulating this scanner model. The simulated model of this scanner can be used for future studies regarding optimization of image reconstruction algorithms and emission acquisition protocols. Wolters Kluwer - Medknow 2020-07-22 /pmc/articles/PMC7875045/ /pubmed/33623506 http://dx.doi.org/10.4103/wjnm.WJNM_4_20 Text en Copyright: © 2020 World Journal of Nuclear Medicine http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Kashian, Elham
Ahangari, Hadi Taleshi
Dehlaghi, Vahab
Khoshgard, Karim
Ghafarian, Pardis
Ghorbani, Raheb
Monte Carlo simulation and performance assessment of GE Discovery 690 VCT positron emission tomography/computed tomography scanner
title Monte Carlo simulation and performance assessment of GE Discovery 690 VCT positron emission tomography/computed tomography scanner
title_full Monte Carlo simulation and performance assessment of GE Discovery 690 VCT positron emission tomography/computed tomography scanner
title_fullStr Monte Carlo simulation and performance assessment of GE Discovery 690 VCT positron emission tomography/computed tomography scanner
title_full_unstemmed Monte Carlo simulation and performance assessment of GE Discovery 690 VCT positron emission tomography/computed tomography scanner
title_short Monte Carlo simulation and performance assessment of GE Discovery 690 VCT positron emission tomography/computed tomography scanner
title_sort monte carlo simulation and performance assessment of ge discovery 690 vct positron emission tomography/computed tomography scanner
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7875045/
https://www.ncbi.nlm.nih.gov/pubmed/33623506
http://dx.doi.org/10.4103/wjnm.WJNM_4_20
work_keys_str_mv AT kashianelham montecarlosimulationandperformanceassessmentofgediscovery690vctpositronemissiontomographycomputedtomographyscanner
AT ahangarihaditaleshi montecarlosimulationandperformanceassessmentofgediscovery690vctpositronemissiontomographycomputedtomographyscanner
AT dehlaghivahab montecarlosimulationandperformanceassessmentofgediscovery690vctpositronemissiontomographycomputedtomographyscanner
AT khoshgardkarim montecarlosimulationandperformanceassessmentofgediscovery690vctpositronemissiontomographycomputedtomographyscanner
AT ghafarianpardis montecarlosimulationandperformanceassessmentofgediscovery690vctpositronemissiontomographycomputedtomographyscanner
AT ghorbaniraheb montecarlosimulationandperformanceassessmentofgediscovery690vctpositronemissiontomographycomputedtomographyscanner