Cargando…

Semi-supervised Planning Method for Breast Electronic Tissue Compensation Treatments Based on Breast Radius and Separation

BACKGROUND: The aim of the study was to develop and assess a technique for the optimization of breast electronic tissue compensation (ECOMP) treatment plans based on the breast radius and separation. MATERIALS AND METHODS: Ten ECOMP plans for 10 breast cancer patients delivered at our institute were...

Descripción completa

Detalles Bibliográficos
Autores principales: Podgorsak, Alexander R., Kumaraswamy, Lalith K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sciendo 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7877265/
https://www.ncbi.nlm.nih.gov/pubmed/33885244
http://dx.doi.org/10.2478/raon-2020-0073
_version_ 1783650133428142080
author Podgorsak, Alexander R.
Kumaraswamy, Lalith K.
author_facet Podgorsak, Alexander R.
Kumaraswamy, Lalith K.
author_sort Podgorsak, Alexander R.
collection PubMed
description BACKGROUND: The aim of the study was to develop and assess a technique for the optimization of breast electronic tissue compensation (ECOMP) treatment plans based on the breast radius and separation. MATERIALS AND METHODS: Ten ECOMP plans for 10 breast cancer patients delivered at our institute were collected for this work. Pre-treatment CT-simulation images were anonymized and input to a framework for estimation of the breast radius and separation for each axial slice. Optimal treatment fluence was estimated based on the breast radius and separation, and a total beam fluence map for both medial and lateral fields was generated. These maps were then imported into the Eclipse Treatment Planning System and used to calculate a dose distribution. The distribution was compared to the original treatment hand-optimized by a medical dosimetrist. An additional comparison was performed by generating plans assuming a single tissue penetration depth determined by averaging the breast radius and separation over the entire treatment volume. Comparisons between treatment plans used the dose homogeneity index (HI; lower number is better). RESULTS: HI was non-inferior between our algorithm (HI = 12.6) and the dosimetrist plans (HI = 9.9) (p-value > 0.05), and was superior than plans obtained using a single penetration depth (HI = 17.0) (p-value < 0.05) averaged over the 10 collected plans. Our semi-supervised algorithm takes approximately 20 seconds for treatment plan generation and runs with minimal user input, which compares favorably with the dosimetrist plans that can take up to 30 minutes of attention for full optimization. CONCLUSIONS: This work indicates the potential clinical utility of a technique for the optimization of ECOMP breast treatments.
format Online
Article
Text
id pubmed-7877265
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Sciendo
record_format MEDLINE/PubMed
spelling pubmed-78772652021-03-01 Semi-supervised Planning Method for Breast Electronic Tissue Compensation Treatments Based on Breast Radius and Separation Podgorsak, Alexander R. Kumaraswamy, Lalith K. Radiol Oncol Research Article BACKGROUND: The aim of the study was to develop and assess a technique for the optimization of breast electronic tissue compensation (ECOMP) treatment plans based on the breast radius and separation. MATERIALS AND METHODS: Ten ECOMP plans for 10 breast cancer patients delivered at our institute were collected for this work. Pre-treatment CT-simulation images were anonymized and input to a framework for estimation of the breast radius and separation for each axial slice. Optimal treatment fluence was estimated based on the breast radius and separation, and a total beam fluence map for both medial and lateral fields was generated. These maps were then imported into the Eclipse Treatment Planning System and used to calculate a dose distribution. The distribution was compared to the original treatment hand-optimized by a medical dosimetrist. An additional comparison was performed by generating plans assuming a single tissue penetration depth determined by averaging the breast radius and separation over the entire treatment volume. Comparisons between treatment plans used the dose homogeneity index (HI; lower number is better). RESULTS: HI was non-inferior between our algorithm (HI = 12.6) and the dosimetrist plans (HI = 9.9) (p-value > 0.05), and was superior than plans obtained using a single penetration depth (HI = 17.0) (p-value < 0.05) averaged over the 10 collected plans. Our semi-supervised algorithm takes approximately 20 seconds for treatment plan generation and runs with minimal user input, which compares favorably with the dosimetrist plans that can take up to 30 minutes of attention for full optimization. CONCLUSIONS: This work indicates the potential clinical utility of a technique for the optimization of ECOMP breast treatments. Sciendo 2020-12-22 /pmc/articles/PMC7877265/ /pubmed/33885244 http://dx.doi.org/10.2478/raon-2020-0073 Text en © 2021 Alexander R. Podgorsak, Lalith K. Kumaraswamy, published by Sciendo http://creativecommons.org/licenses/by-nc-nd/3.0 This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
spellingShingle Research Article
Podgorsak, Alexander R.
Kumaraswamy, Lalith K.
Semi-supervised Planning Method for Breast Electronic Tissue Compensation Treatments Based on Breast Radius and Separation
title Semi-supervised Planning Method for Breast Electronic Tissue Compensation Treatments Based on Breast Radius and Separation
title_full Semi-supervised Planning Method for Breast Electronic Tissue Compensation Treatments Based on Breast Radius and Separation
title_fullStr Semi-supervised Planning Method for Breast Electronic Tissue Compensation Treatments Based on Breast Radius and Separation
title_full_unstemmed Semi-supervised Planning Method for Breast Electronic Tissue Compensation Treatments Based on Breast Radius and Separation
title_short Semi-supervised Planning Method for Breast Electronic Tissue Compensation Treatments Based on Breast Radius and Separation
title_sort semi-supervised planning method for breast electronic tissue compensation treatments based on breast radius and separation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7877265/
https://www.ncbi.nlm.nih.gov/pubmed/33885244
http://dx.doi.org/10.2478/raon-2020-0073
work_keys_str_mv AT podgorsakalexanderr semisupervisedplanningmethodforbreastelectronictissuecompensationtreatmentsbasedonbreastradiusandseparation
AT kumaraswamylalithk semisupervisedplanningmethodforbreastelectronictissuecompensationtreatmentsbasedonbreastradiusandseparation