Cargando…

Image quality of automatic coronary CT angiography reconstruction for patients with HR ≥ 75 bpm using an AI-assisted 16-cm z-coverage CT scanner

BACKGROUND: Coronary CT angiography (CCTA) is a complicated CT exam in comparison to other CT protocols. Exam success highly depends on image assessment of experienced radiologist and the procedure is often time-consuming. This study aims to evaluate feasibility of automatic CCTA reconstruction in 0...

Descripción completa

Detalles Bibliográficos
Autores principales: Yan, Cheng, Zhou, Guofeng, Yang, Xue, Lu, Xiuliang, Zeng, Mengsu, Ji, Min
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7879675/
https://www.ncbi.nlm.nih.gov/pubmed/33573625
http://dx.doi.org/10.1186/s12880-021-00559-7
_version_ 1783650560572915712
author Yan, Cheng
Zhou, Guofeng
Yang, Xue
Lu, Xiuliang
Zeng, Mengsu
Ji, Min
author_facet Yan, Cheng
Zhou, Guofeng
Yang, Xue
Lu, Xiuliang
Zeng, Mengsu
Ji, Min
author_sort Yan, Cheng
collection PubMed
description BACKGROUND: Coronary CT angiography (CCTA) is a complicated CT exam in comparison to other CT protocols. Exam success highly depends on image assessment of experienced radiologist and the procedure is often time-consuming. This study aims to evaluate feasibility of automatic CCTA reconstruction in 0.25 s rotation time, 16 cm coverage CT scanner with best phase selection and AI-assisted motion correction. METHODS: CCTA exams of 90 patients with heart rates higher than 75 bpm were included in this study. Two image series were reconstructed—one at automatically selected phase and another with additional motion correction. All reconstructions were performed without manual interaction of radiologist. A four-point Likert scale rating system was used to evaluate the image quality of coronary artery segment by two experienced radiologists, according to the 18-segment model. Analysis was done on per-segment basis. RESULTS: Total 1194 out of the 1620 segments were identified for quality evaluation in 90 patients. After automatic best phase selection, 1172 segments (98.3%) were rated as having diagnostic image quality (scores 2–4) and the average score is 3.64 ± 0.55. When motion corrections were applied, diagnostic segment number increases to 1192 (99.8%) and the average score is 3.85 ± 0.37. CONCLUSIONS: With the help of 0.25 s rotation speed, 16-cm z-coverage and AI-assisted motion correction algorithm, CCTA exam reconstruction could be performed with minimum radiologist involvement and still meet image quality requirement.
format Online
Article
Text
id pubmed-7879675
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-78796752021-02-17 Image quality of automatic coronary CT angiography reconstruction for patients with HR ≥ 75 bpm using an AI-assisted 16-cm z-coverage CT scanner Yan, Cheng Zhou, Guofeng Yang, Xue Lu, Xiuliang Zeng, Mengsu Ji, Min BMC Med Imaging Original Research BACKGROUND: Coronary CT angiography (CCTA) is a complicated CT exam in comparison to other CT protocols. Exam success highly depends on image assessment of experienced radiologist and the procedure is often time-consuming. This study aims to evaluate feasibility of automatic CCTA reconstruction in 0.25 s rotation time, 16 cm coverage CT scanner with best phase selection and AI-assisted motion correction. METHODS: CCTA exams of 90 patients with heart rates higher than 75 bpm were included in this study. Two image series were reconstructed—one at automatically selected phase and another with additional motion correction. All reconstructions were performed without manual interaction of radiologist. A four-point Likert scale rating system was used to evaluate the image quality of coronary artery segment by two experienced radiologists, according to the 18-segment model. Analysis was done on per-segment basis. RESULTS: Total 1194 out of the 1620 segments were identified for quality evaluation in 90 patients. After automatic best phase selection, 1172 segments (98.3%) were rated as having diagnostic image quality (scores 2–4) and the average score is 3.64 ± 0.55. When motion corrections were applied, diagnostic segment number increases to 1192 (99.8%) and the average score is 3.85 ± 0.37. CONCLUSIONS: With the help of 0.25 s rotation speed, 16-cm z-coverage and AI-assisted motion correction algorithm, CCTA exam reconstruction could be performed with minimum radiologist involvement and still meet image quality requirement. BioMed Central 2021-02-11 /pmc/articles/PMC7879675/ /pubmed/33573625 http://dx.doi.org/10.1186/s12880-021-00559-7 Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Original Research
Yan, Cheng
Zhou, Guofeng
Yang, Xue
Lu, Xiuliang
Zeng, Mengsu
Ji, Min
Image quality of automatic coronary CT angiography reconstruction for patients with HR ≥ 75 bpm using an AI-assisted 16-cm z-coverage CT scanner
title Image quality of automatic coronary CT angiography reconstruction for patients with HR ≥ 75 bpm using an AI-assisted 16-cm z-coverage CT scanner
title_full Image quality of automatic coronary CT angiography reconstruction for patients with HR ≥ 75 bpm using an AI-assisted 16-cm z-coverage CT scanner
title_fullStr Image quality of automatic coronary CT angiography reconstruction for patients with HR ≥ 75 bpm using an AI-assisted 16-cm z-coverage CT scanner
title_full_unstemmed Image quality of automatic coronary CT angiography reconstruction for patients with HR ≥ 75 bpm using an AI-assisted 16-cm z-coverage CT scanner
title_short Image quality of automatic coronary CT angiography reconstruction for patients with HR ≥ 75 bpm using an AI-assisted 16-cm z-coverage CT scanner
title_sort image quality of automatic coronary ct angiography reconstruction for patients with hr ≥ 75 bpm using an ai-assisted 16-cm z-coverage ct scanner
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7879675/
https://www.ncbi.nlm.nih.gov/pubmed/33573625
http://dx.doi.org/10.1186/s12880-021-00559-7
work_keys_str_mv AT yancheng imagequalityofautomaticcoronaryctangiographyreconstructionforpatientswithhr75bpmusinganaiassisted16cmzcoveragectscanner
AT zhouguofeng imagequalityofautomaticcoronaryctangiographyreconstructionforpatientswithhr75bpmusinganaiassisted16cmzcoveragectscanner
AT yangxue imagequalityofautomaticcoronaryctangiographyreconstructionforpatientswithhr75bpmusinganaiassisted16cmzcoveragectscanner
AT luxiuliang imagequalityofautomaticcoronaryctangiographyreconstructionforpatientswithhr75bpmusinganaiassisted16cmzcoveragectscanner
AT zengmengsu imagequalityofautomaticcoronaryctangiographyreconstructionforpatientswithhr75bpmusinganaiassisted16cmzcoveragectscanner
AT jimin imagequalityofautomaticcoronaryctangiographyreconstructionforpatientswithhr75bpmusinganaiassisted16cmzcoveragectscanner