Cargando…

Use of SNP chips to detect rare pathogenic variants: retrospective, population based diagnostic evaluation

OBJECTIVE: To determine whether the sensitivity and specificity of SNP chips are adequate for detecting rare pathogenic variants in a clinically unselected population. DESIGN: Retrospective, population based diagnostic evaluation. PARTICIPANTS: 49 908 people recruited to the UK Biobank with SNP chip...

Descripción completa

Detalles Bibliográficos
Autores principales: MN, Weedon, L, Jackson, JW, Harrison, KS, Ruth, J, Tyrrell, AT, Hattersley, CF, Wright
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group Ltd. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7879796/
https://www.ncbi.nlm.nih.gov/pubmed/33589468
http://dx.doi.org/10.1136/bmj.n214
_version_ 1783650582202941440
author MN, Weedon
L, Jackson
JW, Harrison
KS, Ruth
J, Tyrrell
AT, Hattersley
CF, Wright
author_facet MN, Weedon
L, Jackson
JW, Harrison
KS, Ruth
J, Tyrrell
AT, Hattersley
CF, Wright
author_sort MN, Weedon
collection PubMed
description OBJECTIVE: To determine whether the sensitivity and specificity of SNP chips are adequate for detecting rare pathogenic variants in a clinically unselected population. DESIGN: Retrospective, population based diagnostic evaluation. PARTICIPANTS: 49 908 people recruited to the UK Biobank with SNP chip and next generation sequencing data, and an additional 21 people who purchased consumer genetic tests and shared their data online via the Personal Genome Project. MAIN OUTCOME MEASURES: Genotyping (that is, identification of the correct DNA base at a specific genomic location) using SNP chips versus sequencing, with results split by frequency of that genotype in the population. Rare pathogenic variants in the BRCA1 and BRCA2 genes were selected as an exemplar for detailed analysis of clinically actionable variants in the UK Biobank, and BRCA related cancers (breast, ovarian, prostate, and pancreatic) were assessed in participants through use of cancer registry data. RESULTS: Overall, genotyping using SNP chips performed well compared with sequencing; sensitivity, specificity, positive predictive value, and negative predictive value were all above 99% for 108 574 common variants directly genotyped on the SNP chips and sequenced in the UK Biobank. However, the likelihood of a true positive result decreased dramatically with decreasing variant frequency; for variants that are very rare in the population, with a frequency below 0.001% in UK Biobank, the positive predictive value was very low and only 16% of 4757 heterozygous genotypes from the SNP chips were confirmed with sequencing data. Results were similar for SNP chip data from the Personal Genome Project, and 20/21 individuals analysed had at least one false positive rare pathogenic variant that had been incorrectly genotyped. For pathogenic variants in the BRCA1 and BRCA2 genes, which are individually very rare, the overall performance metrics for the SNP chips versus sequencing in the UK Biobank were: sensitivity 34.6%, specificity 98.3%, positive predictive value 4.2%, and negative predictive value 99.9%. Rates of BRCA related cancers in UK Biobank participants with a positive SNP chip result were similar to those for age matched controls (odds ratio 1.31, 95% confidence interval 0.99 to 1.71) because the vast majority of variants were false positives, whereas sequence positive participants had a significantly increased risk (odds ratio 4.05, 2.72 to 6.03). CONCLUSIONS: SNP chips are extremely unreliable for genotyping very rare pathogenic variants and should not be used to guide health decisions without validation.
format Online
Article
Text
id pubmed-7879796
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BMJ Publishing Group Ltd.
record_format MEDLINE/PubMed
spelling pubmed-78797962021-02-24 Use of SNP chips to detect rare pathogenic variants: retrospective, population based diagnostic evaluation MN, Weedon L, Jackson JW, Harrison KS, Ruth J, Tyrrell AT, Hattersley CF, Wright BMJ Research OBJECTIVE: To determine whether the sensitivity and specificity of SNP chips are adequate for detecting rare pathogenic variants in a clinically unselected population. DESIGN: Retrospective, population based diagnostic evaluation. PARTICIPANTS: 49 908 people recruited to the UK Biobank with SNP chip and next generation sequencing data, and an additional 21 people who purchased consumer genetic tests and shared their data online via the Personal Genome Project. MAIN OUTCOME MEASURES: Genotyping (that is, identification of the correct DNA base at a specific genomic location) using SNP chips versus sequencing, with results split by frequency of that genotype in the population. Rare pathogenic variants in the BRCA1 and BRCA2 genes were selected as an exemplar for detailed analysis of clinically actionable variants in the UK Biobank, and BRCA related cancers (breast, ovarian, prostate, and pancreatic) were assessed in participants through use of cancer registry data. RESULTS: Overall, genotyping using SNP chips performed well compared with sequencing; sensitivity, specificity, positive predictive value, and negative predictive value were all above 99% for 108 574 common variants directly genotyped on the SNP chips and sequenced in the UK Biobank. However, the likelihood of a true positive result decreased dramatically with decreasing variant frequency; for variants that are very rare in the population, with a frequency below 0.001% in UK Biobank, the positive predictive value was very low and only 16% of 4757 heterozygous genotypes from the SNP chips were confirmed with sequencing data. Results were similar for SNP chip data from the Personal Genome Project, and 20/21 individuals analysed had at least one false positive rare pathogenic variant that had been incorrectly genotyped. For pathogenic variants in the BRCA1 and BRCA2 genes, which are individually very rare, the overall performance metrics for the SNP chips versus sequencing in the UK Biobank were: sensitivity 34.6%, specificity 98.3%, positive predictive value 4.2%, and negative predictive value 99.9%. Rates of BRCA related cancers in UK Biobank participants with a positive SNP chip result were similar to those for age matched controls (odds ratio 1.31, 95% confidence interval 0.99 to 1.71) because the vast majority of variants were false positives, whereas sequence positive participants had a significantly increased risk (odds ratio 4.05, 2.72 to 6.03). CONCLUSIONS: SNP chips are extremely unreliable for genotyping very rare pathogenic variants and should not be used to guide health decisions without validation. BMJ Publishing Group Ltd. 2021-02-15 /pmc/articles/PMC7879796/ /pubmed/33589468 http://dx.doi.org/10.1136/bmj.n214 Text en © Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY. No commercial re-use. See rights and permissions. Published by BMJ. http://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed in accordance with the terms of the Creative Commons Attribution (CC BY 4.0) license, which permits others to distribute, remix, adapt and build upon this work, for commercial use, provided the original work is properly cited. See: http://creativecommons.org/licenses/by/4.0/.
spellingShingle Research
MN, Weedon
L, Jackson
JW, Harrison
KS, Ruth
J, Tyrrell
AT, Hattersley
CF, Wright
Use of SNP chips to detect rare pathogenic variants: retrospective, population based diagnostic evaluation
title Use of SNP chips to detect rare pathogenic variants: retrospective, population based diagnostic evaluation
title_full Use of SNP chips to detect rare pathogenic variants: retrospective, population based diagnostic evaluation
title_fullStr Use of SNP chips to detect rare pathogenic variants: retrospective, population based diagnostic evaluation
title_full_unstemmed Use of SNP chips to detect rare pathogenic variants: retrospective, population based diagnostic evaluation
title_short Use of SNP chips to detect rare pathogenic variants: retrospective, population based diagnostic evaluation
title_sort use of snp chips to detect rare pathogenic variants: retrospective, population based diagnostic evaluation
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7879796/
https://www.ncbi.nlm.nih.gov/pubmed/33589468
http://dx.doi.org/10.1136/bmj.n214
work_keys_str_mv AT mnweedon useofsnpchipstodetectrarepathogenicvariantsretrospectivepopulationbaseddiagnosticevaluation
AT ljackson useofsnpchipstodetectrarepathogenicvariantsretrospectivepopulationbaseddiagnosticevaluation
AT jwharrison useofsnpchipstodetectrarepathogenicvariantsretrospectivepopulationbaseddiagnosticevaluation
AT ksruth useofsnpchipstodetectrarepathogenicvariantsretrospectivepopulationbaseddiagnosticevaluation
AT jtyrrell useofsnpchipstodetectrarepathogenicvariantsretrospectivepopulationbaseddiagnosticevaluation
AT athattersley useofsnpchipstodetectrarepathogenicvariantsretrospectivepopulationbaseddiagnosticevaluation
AT cfwright useofsnpchipstodetectrarepathogenicvariantsretrospectivepopulationbaseddiagnosticevaluation