Cargando…

Robotic pancreaticoduodenectomy provides better histopathological outcomes as compared to its open counterpart: a meta-analysis

The aim of this meta-analysis was to evaluate whether robotic pancreaticoduodenectomy (PD) may provide better clinical and pathologic outcomes compared to its open counterpart. The Pubmed, EMBASE, and Cochrane Library were systematically searched. Overall postoperative morbidity and resection margin...

Descripción completa

Detalles Bibliográficos
Autores principales: Da Dong, Xiang, Felsenreich, Daniel Moritz, Gogna, Shekhar, Rojas, Aram, Zhang, Ethan, Dong, Michael, Azim, Asad, Gachabayov, Mahir
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7881190/
https://www.ncbi.nlm.nih.gov/pubmed/33580139
http://dx.doi.org/10.1038/s41598-021-83391-x
_version_ 1783650825809166336
author Da Dong, Xiang
Felsenreich, Daniel Moritz
Gogna, Shekhar
Rojas, Aram
Zhang, Ethan
Dong, Michael
Azim, Asad
Gachabayov, Mahir
author_facet Da Dong, Xiang
Felsenreich, Daniel Moritz
Gogna, Shekhar
Rojas, Aram
Zhang, Ethan
Dong, Michael
Azim, Asad
Gachabayov, Mahir
author_sort Da Dong, Xiang
collection PubMed
description The aim of this meta-analysis was to evaluate whether robotic pancreaticoduodenectomy (PD) may provide better clinical and pathologic outcomes compared to its open counterpart. The Pubmed, EMBASE, and Cochrane Library were systematically searched. Overall postoperative morbidity and resection margin involvement rate were the primary endpoints. Secondary endpoints included operating time, estimated blood loss (EBL), incisional surgical site infection (SSI) rate, length of hospital stay (LOS), and number of lymph nodes harvested. Twenty-four studies totaling 12,579 patients (2,175 robotic PD and 10,404 open PD were included. Overall postoperative mortality did not significantly differ [OR (95%CI) = 0.86 (0.74, 1.01); p = 0.06]. Resection margin involvement rate was significantly lower in robotic PD [15.6% vs. 19.9%; OR (95%CI) = 0.64 (0.41, 1.00); p = 0.05; NNT = 23]. Operating time was significantly longer in robotic PD [MD (95%CI) = 75.17 (48.05, 102.28); p < 0.00001]. EBL was significantly decreased in robotic PD [MD (95%CI) = − 191.35 (− 238.12, − 144.59); p < 0.00001]. Number of lymph nodes harvested was significantly higher in robotic PD [MD (95%CI) = 2.88 (1.12, 4.65); p = 0.001]. This meta-analysis found that robotic PD provides better histopathological outcomes as compared to open PD at the cost of longer operating time. Furthermore, robotic PD did not have any detrimental impact on clinical outcomes, with lower wound infection rates.
format Online
Article
Text
id pubmed-7881190
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-78811902021-02-16 Robotic pancreaticoduodenectomy provides better histopathological outcomes as compared to its open counterpart: a meta-analysis Da Dong, Xiang Felsenreich, Daniel Moritz Gogna, Shekhar Rojas, Aram Zhang, Ethan Dong, Michael Azim, Asad Gachabayov, Mahir Sci Rep Article The aim of this meta-analysis was to evaluate whether robotic pancreaticoduodenectomy (PD) may provide better clinical and pathologic outcomes compared to its open counterpart. The Pubmed, EMBASE, and Cochrane Library were systematically searched. Overall postoperative morbidity and resection margin involvement rate were the primary endpoints. Secondary endpoints included operating time, estimated blood loss (EBL), incisional surgical site infection (SSI) rate, length of hospital stay (LOS), and number of lymph nodes harvested. Twenty-four studies totaling 12,579 patients (2,175 robotic PD and 10,404 open PD were included. Overall postoperative mortality did not significantly differ [OR (95%CI) = 0.86 (0.74, 1.01); p = 0.06]. Resection margin involvement rate was significantly lower in robotic PD [15.6% vs. 19.9%; OR (95%CI) = 0.64 (0.41, 1.00); p = 0.05; NNT = 23]. Operating time was significantly longer in robotic PD [MD (95%CI) = 75.17 (48.05, 102.28); p < 0.00001]. EBL was significantly decreased in robotic PD [MD (95%CI) = − 191.35 (− 238.12, − 144.59); p < 0.00001]. Number of lymph nodes harvested was significantly higher in robotic PD [MD (95%CI) = 2.88 (1.12, 4.65); p = 0.001]. This meta-analysis found that robotic PD provides better histopathological outcomes as compared to open PD at the cost of longer operating time. Furthermore, robotic PD did not have any detrimental impact on clinical outcomes, with lower wound infection rates. Nature Publishing Group UK 2021-02-12 /pmc/articles/PMC7881190/ /pubmed/33580139 http://dx.doi.org/10.1038/s41598-021-83391-x Text en © The Author(s) 2021 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Da Dong, Xiang
Felsenreich, Daniel Moritz
Gogna, Shekhar
Rojas, Aram
Zhang, Ethan
Dong, Michael
Azim, Asad
Gachabayov, Mahir
Robotic pancreaticoduodenectomy provides better histopathological outcomes as compared to its open counterpart: a meta-analysis
title Robotic pancreaticoduodenectomy provides better histopathological outcomes as compared to its open counterpart: a meta-analysis
title_full Robotic pancreaticoduodenectomy provides better histopathological outcomes as compared to its open counterpart: a meta-analysis
title_fullStr Robotic pancreaticoduodenectomy provides better histopathological outcomes as compared to its open counterpart: a meta-analysis
title_full_unstemmed Robotic pancreaticoduodenectomy provides better histopathological outcomes as compared to its open counterpart: a meta-analysis
title_short Robotic pancreaticoduodenectomy provides better histopathological outcomes as compared to its open counterpart: a meta-analysis
title_sort robotic pancreaticoduodenectomy provides better histopathological outcomes as compared to its open counterpart: a meta-analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7881190/
https://www.ncbi.nlm.nih.gov/pubmed/33580139
http://dx.doi.org/10.1038/s41598-021-83391-x
work_keys_str_mv AT dadongxiang roboticpancreaticoduodenectomyprovidesbetterhistopathologicaloutcomesascomparedtoitsopencounterpartametaanalysis
AT felsenreichdanielmoritz roboticpancreaticoduodenectomyprovidesbetterhistopathologicaloutcomesascomparedtoitsopencounterpartametaanalysis
AT gognashekhar roboticpancreaticoduodenectomyprovidesbetterhistopathologicaloutcomesascomparedtoitsopencounterpartametaanalysis
AT rojasaram roboticpancreaticoduodenectomyprovidesbetterhistopathologicaloutcomesascomparedtoitsopencounterpartametaanalysis
AT zhangethan roboticpancreaticoduodenectomyprovidesbetterhistopathologicaloutcomesascomparedtoitsopencounterpartametaanalysis
AT dongmichael roboticpancreaticoduodenectomyprovidesbetterhistopathologicaloutcomesascomparedtoitsopencounterpartametaanalysis
AT azimasad roboticpancreaticoduodenectomyprovidesbetterhistopathologicaloutcomesascomparedtoitsopencounterpartametaanalysis
AT gachabayovmahir roboticpancreaticoduodenectomyprovidesbetterhistopathologicaloutcomesascomparedtoitsopencounterpartametaanalysis