Cargando…

VR/AR Head-mounted Display System-based Measurement and Evaluation of Dynamic Visual Acuity

This study evaluated the dynamic visual acuity of candidates by implementing a King–Devick (K-D) test chart in a virtual reality head-mounted display (VR HMD) and an augmented reality head-mounted display (AR HMD). Hard-copy KD (HCKD), VR HMD KD (VHKD), and AR HMD KD (AHKD) tests were conducted in 3...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Jung-Ho, Son, Ho-Jun, Lee, Seung-Hyun, Kwon, Soon-Chul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bern Open Publishing 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7881879/
https://www.ncbi.nlm.nih.gov/pubmed/33828774
http://dx.doi.org/10.16910/jemr.12.8.1
Descripción
Sumario:This study evaluated the dynamic visual acuity of candidates by implementing a King–Devick (K-D) test chart in a virtual reality head-mounted display (VR HMD) and an augmented reality head-mounted display (AR HMD). Hard-copy KD (HCKD), VR HMD KD (VHKD), and AR HMD KD (AHKD) tests were conducted in 30 male and female candidates in the age of 10S and 20S and subjective symptom surveys were conducted. In the subjective symptom surveys, all except one of the VHKD questionnaire items showed subjective symptoms of less than 1 point. In the comparison between HCKD and VHKD, HCKD was measured more rapidly than VHKD in all tests. In the comparison between HCKD and AHKD, HCKD was measured more rapidly than AHKD in Tests 1, 2, and 3. In the comparison between VHKD and AHKD, AHKD was measured more rapidly than VHKD in Tests 1, 2, and 3. In the correlation analyses of test platforms, all platforms were correlated with each other, except for the correlation between HCKD and VHKD in Tests 1 and 2. There was no significant difference in the frequency of errors among Tests 1, 2, and 3 across test platforms. VHKD and AHKD, which require the body to be moved to read the chart, required longer measurement time than HCKD. In the measurements of each platform, AHKD was measured closer to HCKD than VHKD, which may be because the AHKD environment is closer to the actual environment than the VHKD environment. The effectiveness of VHKD and AHKD proposed in this research was evaluated experimentally. The results suggest that treatment and training could be performed concurrently through the use of clinical test and content development of VHKD and AHKD.