Cargando…
An analytical expression for R50% dependent on PTV surface area and volume: A cranial SRS comparison
The intermediate dose spill for a stereotactic radiosurgery (SRS) plan can be quantified with the metric R50%, defined as the 50% isodose cloud volume (V(IDC50%)) divided by the volume of the planning target volume (PTV). By coupling sound physical principles with the basic definition of R50%, we de...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7882107/ https://www.ncbi.nlm.nih.gov/pubmed/33493385 http://dx.doi.org/10.1002/acm2.13168 |
_version_ | 1783650994177966080 |
---|---|
author | Desai, Dharmin D. Johnson, E. L. Cordrey, Ivan L. |
author_facet | Desai, Dharmin D. Johnson, E. L. Cordrey, Ivan L. |
author_sort | Desai, Dharmin D. |
collection | PubMed |
description | The intermediate dose spill for a stereotactic radiosurgery (SRS) plan can be quantified with the metric R50%, defined as the 50% isodose cloud volume (V(IDC50%)) divided by the volume of the planning target volume (PTV). By coupling sound physical principles with the basic definition of R50%, we derive an analytical expression for R50% for a spherical PTV. Our analytical expression depends on three quantities: the surface area of PTV (SA(PTV)), the volume of PTV (V(PTV)), and the distance of dose drop‐off to 50% (Δr). The value of ∆r was obtained from a simple set of cranial phantom plan calculations. We generate values from our analytical expression for R50% (R50%(Analytic)) and compare the values to clinical R50% values (R50%(Clinical)) extracted from a previously published SRS data set that spans the V(PTV) range from 0.15 to 50.1 cm(3). R50%(Analytic) is smaller than R50%(Clinical) in all cases by an average of 15% ± 7%, and the general trend of R50%(Clinical) vs V(PTV) is reflected in the same trend of R50%(Analytic). This comparison suggests that R50%(Analytic) could represent a theoretical lower limit for the clinical SRS data; further investigation is required to confirm this. R50%(Analytic) could provide useful guidance for what might be achievable in SRS planning. |
format | Online Article Text |
id | pubmed-7882107 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-78821072021-02-19 An analytical expression for R50% dependent on PTV surface area and volume: A cranial SRS comparison Desai, Dharmin D. Johnson, E. L. Cordrey, Ivan L. J Appl Clin Med Phys Technical Notes The intermediate dose spill for a stereotactic radiosurgery (SRS) plan can be quantified with the metric R50%, defined as the 50% isodose cloud volume (V(IDC50%)) divided by the volume of the planning target volume (PTV). By coupling sound physical principles with the basic definition of R50%, we derive an analytical expression for R50% for a spherical PTV. Our analytical expression depends on three quantities: the surface area of PTV (SA(PTV)), the volume of PTV (V(PTV)), and the distance of dose drop‐off to 50% (Δr). The value of ∆r was obtained from a simple set of cranial phantom plan calculations. We generate values from our analytical expression for R50% (R50%(Analytic)) and compare the values to clinical R50% values (R50%(Clinical)) extracted from a previously published SRS data set that spans the V(PTV) range from 0.15 to 50.1 cm(3). R50%(Analytic) is smaller than R50%(Clinical) in all cases by an average of 15% ± 7%, and the general trend of R50%(Clinical) vs V(PTV) is reflected in the same trend of R50%(Analytic). This comparison suggests that R50%(Analytic) could represent a theoretical lower limit for the clinical SRS data; further investigation is required to confirm this. R50%(Analytic) could provide useful guidance for what might be achievable in SRS planning. John Wiley and Sons Inc. 2021-01-25 /pmc/articles/PMC7882107/ /pubmed/33493385 http://dx.doi.org/10.1002/acm2.13168 Text en © 2021 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Technical Notes Desai, Dharmin D. Johnson, E. L. Cordrey, Ivan L. An analytical expression for R50% dependent on PTV surface area and volume: A cranial SRS comparison |
title | An analytical expression for R50% dependent on PTV surface area and volume: A cranial SRS comparison |
title_full | An analytical expression for R50% dependent on PTV surface area and volume: A cranial SRS comparison |
title_fullStr | An analytical expression for R50% dependent on PTV surface area and volume: A cranial SRS comparison |
title_full_unstemmed | An analytical expression for R50% dependent on PTV surface area and volume: A cranial SRS comparison |
title_short | An analytical expression for R50% dependent on PTV surface area and volume: A cranial SRS comparison |
title_sort | analytical expression for r50% dependent on ptv surface area and volume: a cranial srs comparison |
topic | Technical Notes |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7882107/ https://www.ncbi.nlm.nih.gov/pubmed/33493385 http://dx.doi.org/10.1002/acm2.13168 |
work_keys_str_mv | AT desaidharmind ananalyticalexpressionforr50dependentonptvsurfaceareaandvolumeacranialsrscomparison AT johnsonel ananalyticalexpressionforr50dependentonptvsurfaceareaandvolumeacranialsrscomparison AT cordreyivanl ananalyticalexpressionforr50dependentonptvsurfaceareaandvolumeacranialsrscomparison AT desaidharmind analyticalexpressionforr50dependentonptvsurfaceareaandvolumeacranialsrscomparison AT johnsonel analyticalexpressionforr50dependentonptvsurfaceareaandvolumeacranialsrscomparison AT cordreyivanl analyticalexpressionforr50dependentonptvsurfaceareaandvolumeacranialsrscomparison |