Simulation of an HDR “Boost” with Stereotactic Proton versus Photon Therapy in Prostate Cancer: A Dosimetric Feasibility Study
PURPOSE/OBJECTIVES: To compare the dose escalation potential of stereotactic body proton therapy (SBPT) versus stereotactic body photon therapy (SBXT) using high-dose rate prostate brachytherapy (HDR-B) dose-prescription metrics. PATIENTS AND METHODS: Twenty-five patients previously treated with rad...
Autores principales: | Remick, Jill S., Sabouri, Pouya, Zhu, Mingyao, Bentzen, Søren M., Sun, Kai, Kwok, Young, Kaiser, Adeel |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Particle Therapy Co-operative Group
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7886266/ https://www.ncbi.nlm.nih.gov/pubmed/33604412 http://dx.doi.org/10.14338/IJPT-20-00029.1 |
Ejemplares similares
-
Feasibility of Proton Transmission-Beam Stereotactic Ablative Radiotherapy versus Photon Stereotactic Ablative Radiotherapy for Lung Tumors: A Dosimetric and Feasibility Study
por: Mou, Benjamin, et al.
Publicado: (2014) -
Multiple Computed Tomography Robust Optimization to Account for Random Anatomic Density Variations During Intensity Modulated Proton Therapy
por: Zhu, Mingyao, et al.
Publicado: (2019) -
Dosimetric comparison of surface mould HDR brachytherapy with VMAT
por: Boman, Eeva L., et al.
Publicado: (2018) -
Dosimetric analysis and comparison of IMRT and HDR brachytherapy in treatment of localized prostate cancer
por: Murali, V., et al.
Publicado: (2010) -
Dosimetric Comparison of Upfront Boosting With Stereotactic Radiosurgery Versus Intraoperative Radiotherapy for Glioblastoma
por: Sarria, Gustavo R., et al.
Publicado: (2021)