Cargando…
Association of Apgar Score With Meconium Staining of Amniotic Fluid in Labor
Objective This study aimed to determine the association of Apgar score with meconium staining of amniotic fluid in labor. Methodology A retrospective observational study was carried out through the non-probability convenient sampling technique at the Department of Obstetrics and Gynecology for a dur...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7886603/ https://www.ncbi.nlm.nih.gov/pubmed/33614343 http://dx.doi.org/10.7759/cureus.12744 |
_version_ | 1783651830892331008 |
---|---|
author | Masood, Mehar Shahid, Nadia Bano, Zakia Ali Khan, Fiza Hussain, Syeda Fariha Uroosa, Hafiza Khan, Muzainah Anwar, Adnan Hashmi, Atif A |
author_facet | Masood, Mehar Shahid, Nadia Bano, Zakia Ali Khan, Fiza Hussain, Syeda Fariha Uroosa, Hafiza Khan, Muzainah Anwar, Adnan Hashmi, Atif A |
author_sort | Masood, Mehar |
collection | PubMed |
description | Objective This study aimed to determine the association of Apgar score with meconium staining of amniotic fluid in labor. Methodology A retrospective observational study was carried out through the non-probability convenient sampling technique at the Department of Obstetrics and Gynecology for a duration of six months. Only those women were selected who had more than 24 weeks of gestation period. The women were excluded on the basis of risk factors for fetal distress and breech in late labor. Results A total of 216 pregnant women were selected from the labor room in this study. The mean age of the women was 26.57±4.28 years. The gestational age of the women was 36.09±4.11 weeks. Moreover, the mean parity of pregnant women was 1.68±2.53. It has been observed that the women who had meconium staining, the neonates of 144(77.4%) women showed the Apgar score of less than six at one minute. However, for the women without meconium staining, the neonates of only 15(50%) women showed the Apgar score of less than six at the one-minute interval with a significant association (p=0.02). With respect to age groups, a significant association of meconium staining with Apgar score was noted in the 21-30 years age group, whereas, no significant association was seen in other age groups. Similarly, a significant association of meconium staining and Apgar score was noted in primiparous women, whereas, no significant association was noted in multiparous women. No significant association of Apgar score and meconium staining was seen with respect to the mode of delivery. Conclusion The study has found a relation between the Apgar score and meconium staining of amniotic fluid and reported that the Apgar score of less than six at one minute was significantly associated with meconium staining of amniotic fluid. |
format | Online Article Text |
id | pubmed-7886603 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-78866032021-02-19 Association of Apgar Score With Meconium Staining of Amniotic Fluid in Labor Masood, Mehar Shahid, Nadia Bano, Zakia Ali Khan, Fiza Hussain, Syeda Fariha Uroosa, Hafiza Khan, Muzainah Anwar, Adnan Hashmi, Atif A Cureus Obstetrics/Gynecology Objective This study aimed to determine the association of Apgar score with meconium staining of amniotic fluid in labor. Methodology A retrospective observational study was carried out through the non-probability convenient sampling technique at the Department of Obstetrics and Gynecology for a duration of six months. Only those women were selected who had more than 24 weeks of gestation period. The women were excluded on the basis of risk factors for fetal distress and breech in late labor. Results A total of 216 pregnant women were selected from the labor room in this study. The mean age of the women was 26.57±4.28 years. The gestational age of the women was 36.09±4.11 weeks. Moreover, the mean parity of pregnant women was 1.68±2.53. It has been observed that the women who had meconium staining, the neonates of 144(77.4%) women showed the Apgar score of less than six at one minute. However, for the women without meconium staining, the neonates of only 15(50%) women showed the Apgar score of less than six at the one-minute interval with a significant association (p=0.02). With respect to age groups, a significant association of meconium staining with Apgar score was noted in the 21-30 years age group, whereas, no significant association was seen in other age groups. Similarly, a significant association of meconium staining and Apgar score was noted in primiparous women, whereas, no significant association was noted in multiparous women. No significant association of Apgar score and meconium staining was seen with respect to the mode of delivery. Conclusion The study has found a relation between the Apgar score and meconium staining of amniotic fluid and reported that the Apgar score of less than six at one minute was significantly associated with meconium staining of amniotic fluid. Cureus 2021-01-16 /pmc/articles/PMC7886603/ /pubmed/33614343 http://dx.doi.org/10.7759/cureus.12744 Text en Copyright © 2021, Masood et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Obstetrics/Gynecology Masood, Mehar Shahid, Nadia Bano, Zakia Ali Khan, Fiza Hussain, Syeda Fariha Uroosa, Hafiza Khan, Muzainah Anwar, Adnan Hashmi, Atif A Association of Apgar Score With Meconium Staining of Amniotic Fluid in Labor |
title | Association of Apgar Score With Meconium Staining of Amniotic Fluid in Labor |
title_full | Association of Apgar Score With Meconium Staining of Amniotic Fluid in Labor |
title_fullStr | Association of Apgar Score With Meconium Staining of Amniotic Fluid in Labor |
title_full_unstemmed | Association of Apgar Score With Meconium Staining of Amniotic Fluid in Labor |
title_short | Association of Apgar Score With Meconium Staining of Amniotic Fluid in Labor |
title_sort | association of apgar score with meconium staining of amniotic fluid in labor |
topic | Obstetrics/Gynecology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7886603/ https://www.ncbi.nlm.nih.gov/pubmed/33614343 http://dx.doi.org/10.7759/cureus.12744 |
work_keys_str_mv | AT masoodmehar associationofapgarscorewithmeconiumstainingofamnioticfluidinlabor AT shahidnadia associationofapgarscorewithmeconiumstainingofamnioticfluidinlabor AT banozakia associationofapgarscorewithmeconiumstainingofamnioticfluidinlabor AT alikhanfiza associationofapgarscorewithmeconiumstainingofamnioticfluidinlabor AT hussainsyedafariha associationofapgarscorewithmeconiumstainingofamnioticfluidinlabor AT uroosahafiza associationofapgarscorewithmeconiumstainingofamnioticfluidinlabor AT khanmuzainah associationofapgarscorewithmeconiumstainingofamnioticfluidinlabor AT anwaradnan associationofapgarscorewithmeconiumstainingofamnioticfluidinlabor AT hashmiatifa associationofapgarscorewithmeconiumstainingofamnioticfluidinlabor |