INTRODUCTION: Foldable hydrophobic acrylic intraocular lenses (IOLs) are prone to develop a long-term postoperative material change called glistenings. The aim of this study was to investigate the changes in the predisposition for glistening formation in one type of hydrophobic acrylic IOL material...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Qiang, Yildirim, Timur M., Schickhardt, Sonja K., Łabuz, Grzegorz, Khoramnia, Ramin, Merz, Patrick R., Son, Hyeck-Soo, Munro, Donald J., Friedmann, Elfriede, Auffarth, Gerd U.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Healthcare 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7886932/
https://www.ncbi.nlm.nih.gov/pubmed/33544374
http://dx.doi.org/10.1007/s40123-020-00329-8
_version_ 1783651903711739904
author Wang, Qiang
Yildirim, Timur M.
Schickhardt, Sonja K.
Łabuz, Grzegorz
Khoramnia, Ramin
Merz, Patrick R.
Son, Hyeck-Soo
Munro, Donald J.
Friedmann, Elfriede
Auffarth, Gerd U.
author_facet Wang, Qiang
Yildirim, Timur M.
Schickhardt, Sonja K.
Łabuz, Grzegorz
Khoramnia, Ramin
Merz, Patrick R.
Son, Hyeck-Soo
Munro, Donald J.
Friedmann, Elfriede
Auffarth, Gerd U.
author_sort Wang, Qiang
collection PubMed
description INTRODUCTION: Foldable hydrophobic acrylic intraocular lenses (IOLs) are prone to develop a long-term postoperative material change called glistenings. The aim of this study was to investigate the changes in the predisposition for glistening formation in one type of hydrophobic acrylic IOL material from its introduction to the present day. METHODS: In a laboratory setup, an in vitro model was used to induce glistenings in hydrophobic acrylic IOLs manufactured by one company (Alcon, Fort Worth, TX, USA) in different years: 23 1990s-manufacture hydrophobic acrylic three-piece IOLs (MA30BA/MA60AC) that were explanted in 1996 and 1997, and five of each of the newer AcrySof IOL models (MA60AC, SA60AT, TFNT00 and SN60WF) from 2014 to 2017. Furthermore, five Clareon (SY60WF) IOLs were put through the same accelerated aging procedure. The number of microvacuoles per square millimeter (MV/mm(2)) was determined in the central part of each IOL optic and compared between the groups. RESULTS: The mean number of MV was highest in the 1990s-manufacture Alcon acrylic IOLs, with 1289 (± 738) MV/mm(2). The number decreased to 650 (± 101), 192 (± 105), 175 (± 112) and 47 (± 26) for MA60AC, SA60AT, TFNT00 and SN60WF, respectively. The lowest count was obtained in the Clareon group, with 1 (± 1) MV/mm(2). CONCLUSIONS: A high number of glistenings was induced in the explanted IOLs from the 1990s. The propensity for glistening formation decreased considerably after that decade and now in current use. Even though in vitro glistening formation in today’s AcrySof material was low, the Clareon material was essentially glistenings-free.
format Online
Article
Text
id pubmed-7886932
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Healthcare
record_format MEDLINE/PubMed
spelling pubmed-78869322021-03-03 Quantification of the In Vitro Predisposition to Glistening Formation in One Manufacturer’s Acrylic Intraocular Lenses Made in Different Decades Wang, Qiang Yildirim, Timur M. Schickhardt, Sonja K. Łabuz, Grzegorz Khoramnia, Ramin Merz, Patrick R. Son, Hyeck-Soo Munro, Donald J. Friedmann, Elfriede Auffarth, Gerd U. Ophthalmol Ther Original Research INTRODUCTION: Foldable hydrophobic acrylic intraocular lenses (IOLs) are prone to develop a long-term postoperative material change called glistenings. The aim of this study was to investigate the changes in the predisposition for glistening formation in one type of hydrophobic acrylic IOL material from its introduction to the present day. METHODS: In a laboratory setup, an in vitro model was used to induce glistenings in hydrophobic acrylic IOLs manufactured by one company (Alcon, Fort Worth, TX, USA) in different years: 23 1990s-manufacture hydrophobic acrylic three-piece IOLs (MA30BA/MA60AC) that were explanted in 1996 and 1997, and five of each of the newer AcrySof IOL models (MA60AC, SA60AT, TFNT00 and SN60WF) from 2014 to 2017. Furthermore, five Clareon (SY60WF) IOLs were put through the same accelerated aging procedure. The number of microvacuoles per square millimeter (MV/mm(2)) was determined in the central part of each IOL optic and compared between the groups. RESULTS: The mean number of MV was highest in the 1990s-manufacture Alcon acrylic IOLs, with 1289 (± 738) MV/mm(2). The number decreased to 650 (± 101), 192 (± 105), 175 (± 112) and 47 (± 26) for MA60AC, SA60AT, TFNT00 and SN60WF, respectively. The lowest count was obtained in the Clareon group, with 1 (± 1) MV/mm(2). CONCLUSIONS: A high number of glistenings was induced in the explanted IOLs from the 1990s. The propensity for glistening formation decreased considerably after that decade and now in current use. Even though in vitro glistening formation in today’s AcrySof material was low, the Clareon material was essentially glistenings-free. Springer Healthcare 2021-02-05 2021-03 /pmc/articles/PMC7886932/ /pubmed/33544374 http://dx.doi.org/10.1007/s40123-020-00329-8 Text en © The Author(s) 2021 Open Access This article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License, which permits any non-commercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc/4.0/.
spellingShingle Original Research
Wang, Qiang
Yildirim, Timur M.
Schickhardt, Sonja K.
Łabuz, Grzegorz
Khoramnia, Ramin
Merz, Patrick R.
Son, Hyeck-Soo
Munro, Donald J.
Friedmann, Elfriede
Auffarth, Gerd U.
Quantification of the In Vitro Predisposition to Glistening Formation in One Manufacturer’s Acrylic Intraocular Lenses Made in Different Decades
title Quantification of the In Vitro Predisposition to Glistening Formation in One Manufacturer’s Acrylic Intraocular Lenses Made in Different Decades
title_full Quantification of the In Vitro Predisposition to Glistening Formation in One Manufacturer’s Acrylic Intraocular Lenses Made in Different Decades
title_fullStr Quantification of the In Vitro Predisposition to Glistening Formation in One Manufacturer’s Acrylic Intraocular Lenses Made in Different Decades
title_full_unstemmed Quantification of the In Vitro Predisposition to Glistening Formation in One Manufacturer’s Acrylic Intraocular Lenses Made in Different Decades
title_short Quantification of the In Vitro Predisposition to Glistening Formation in One Manufacturer’s Acrylic Intraocular Lenses Made in Different Decades
title_sort quantification of the in vitro predisposition to glistening formation in one manufacturer’s acrylic intraocular lenses made in different decades
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7886932/
https://www.ncbi.nlm.nih.gov/pubmed/33544374
http://dx.doi.org/10.1007/s40123-020-00329-8
work_keys_str_mv AT wangqiang quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades
AT yildirimtimurm quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades
AT schickhardtsonjak quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades
AT łabuzgrzegorz quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades
AT khoramniaramin quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades
AT merzpatrickr quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades
AT sonhyecksoo quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades
AT munrodonaldj quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades
AT friedmannelfriede quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades
AT auffarthgerdu quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades