Cargando…
Quantification of the In Vitro Predisposition to Glistening Formation in One Manufacturer’s Acrylic Intraocular Lenses Made in Different Decades
INTRODUCTION: Foldable hydrophobic acrylic intraocular lenses (IOLs) are prone to develop a long-term postoperative material change called glistenings. The aim of this study was to investigate the changes in the predisposition for glistening formation in one type of hydrophobic acrylic IOL material...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Healthcare
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7886932/ https://www.ncbi.nlm.nih.gov/pubmed/33544374 http://dx.doi.org/10.1007/s40123-020-00329-8 |
_version_ | 1783651903711739904 |
---|---|
author | Wang, Qiang Yildirim, Timur M. Schickhardt, Sonja K. Łabuz, Grzegorz Khoramnia, Ramin Merz, Patrick R. Son, Hyeck-Soo Munro, Donald J. Friedmann, Elfriede Auffarth, Gerd U. |
author_facet | Wang, Qiang Yildirim, Timur M. Schickhardt, Sonja K. Łabuz, Grzegorz Khoramnia, Ramin Merz, Patrick R. Son, Hyeck-Soo Munro, Donald J. Friedmann, Elfriede Auffarth, Gerd U. |
author_sort | Wang, Qiang |
collection | PubMed |
description | INTRODUCTION: Foldable hydrophobic acrylic intraocular lenses (IOLs) are prone to develop a long-term postoperative material change called glistenings. The aim of this study was to investigate the changes in the predisposition for glistening formation in one type of hydrophobic acrylic IOL material from its introduction to the present day. METHODS: In a laboratory setup, an in vitro model was used to induce glistenings in hydrophobic acrylic IOLs manufactured by one company (Alcon, Fort Worth, TX, USA) in different years: 23 1990s-manufacture hydrophobic acrylic three-piece IOLs (MA30BA/MA60AC) that were explanted in 1996 and 1997, and five of each of the newer AcrySof IOL models (MA60AC, SA60AT, TFNT00 and SN60WF) from 2014 to 2017. Furthermore, five Clareon (SY60WF) IOLs were put through the same accelerated aging procedure. The number of microvacuoles per square millimeter (MV/mm(2)) was determined in the central part of each IOL optic and compared between the groups. RESULTS: The mean number of MV was highest in the 1990s-manufacture Alcon acrylic IOLs, with 1289 (± 738) MV/mm(2). The number decreased to 650 (± 101), 192 (± 105), 175 (± 112) and 47 (± 26) for MA60AC, SA60AT, TFNT00 and SN60WF, respectively. The lowest count was obtained in the Clareon group, with 1 (± 1) MV/mm(2). CONCLUSIONS: A high number of glistenings was induced in the explanted IOLs from the 1990s. The propensity for glistening formation decreased considerably after that decade and now in current use. Even though in vitro glistening formation in today’s AcrySof material was low, the Clareon material was essentially glistenings-free. |
format | Online Article Text |
id | pubmed-7886932 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Healthcare |
record_format | MEDLINE/PubMed |
spelling | pubmed-78869322021-03-03 Quantification of the In Vitro Predisposition to Glistening Formation in One Manufacturer’s Acrylic Intraocular Lenses Made in Different Decades Wang, Qiang Yildirim, Timur M. Schickhardt, Sonja K. Łabuz, Grzegorz Khoramnia, Ramin Merz, Patrick R. Son, Hyeck-Soo Munro, Donald J. Friedmann, Elfriede Auffarth, Gerd U. Ophthalmol Ther Original Research INTRODUCTION: Foldable hydrophobic acrylic intraocular lenses (IOLs) are prone to develop a long-term postoperative material change called glistenings. The aim of this study was to investigate the changes in the predisposition for glistening formation in one type of hydrophobic acrylic IOL material from its introduction to the present day. METHODS: In a laboratory setup, an in vitro model was used to induce glistenings in hydrophobic acrylic IOLs manufactured by one company (Alcon, Fort Worth, TX, USA) in different years: 23 1990s-manufacture hydrophobic acrylic three-piece IOLs (MA30BA/MA60AC) that were explanted in 1996 and 1997, and five of each of the newer AcrySof IOL models (MA60AC, SA60AT, TFNT00 and SN60WF) from 2014 to 2017. Furthermore, five Clareon (SY60WF) IOLs were put through the same accelerated aging procedure. The number of microvacuoles per square millimeter (MV/mm(2)) was determined in the central part of each IOL optic and compared between the groups. RESULTS: The mean number of MV was highest in the 1990s-manufacture Alcon acrylic IOLs, with 1289 (± 738) MV/mm(2). The number decreased to 650 (± 101), 192 (± 105), 175 (± 112) and 47 (± 26) for MA60AC, SA60AT, TFNT00 and SN60WF, respectively. The lowest count was obtained in the Clareon group, with 1 (± 1) MV/mm(2). CONCLUSIONS: A high number of glistenings was induced in the explanted IOLs from the 1990s. The propensity for glistening formation decreased considerably after that decade and now in current use. Even though in vitro glistening formation in today’s AcrySof material was low, the Clareon material was essentially glistenings-free. Springer Healthcare 2021-02-05 2021-03 /pmc/articles/PMC7886932/ /pubmed/33544374 http://dx.doi.org/10.1007/s40123-020-00329-8 Text en © The Author(s) 2021 Open Access This article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License, which permits any non-commercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc/4.0/. |
spellingShingle | Original Research Wang, Qiang Yildirim, Timur M. Schickhardt, Sonja K. Łabuz, Grzegorz Khoramnia, Ramin Merz, Patrick R. Son, Hyeck-Soo Munro, Donald J. Friedmann, Elfriede Auffarth, Gerd U. Quantification of the In Vitro Predisposition to Glistening Formation in One Manufacturer’s Acrylic Intraocular Lenses Made in Different Decades |
title | Quantification of the In Vitro Predisposition to Glistening Formation in One Manufacturer’s Acrylic Intraocular Lenses Made in Different Decades |
title_full | Quantification of the In Vitro Predisposition to Glistening Formation in One Manufacturer’s Acrylic Intraocular Lenses Made in Different Decades |
title_fullStr | Quantification of the In Vitro Predisposition to Glistening Formation in One Manufacturer’s Acrylic Intraocular Lenses Made in Different Decades |
title_full_unstemmed | Quantification of the In Vitro Predisposition to Glistening Formation in One Manufacturer’s Acrylic Intraocular Lenses Made in Different Decades |
title_short | Quantification of the In Vitro Predisposition to Glistening Formation in One Manufacturer’s Acrylic Intraocular Lenses Made in Different Decades |
title_sort | quantification of the in vitro predisposition to glistening formation in one manufacturer’s acrylic intraocular lenses made in different decades |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7886932/ https://www.ncbi.nlm.nih.gov/pubmed/33544374 http://dx.doi.org/10.1007/s40123-020-00329-8 |
work_keys_str_mv | AT wangqiang quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades AT yildirimtimurm quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades AT schickhardtsonjak quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades AT łabuzgrzegorz quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades AT khoramniaramin quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades AT merzpatrickr quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades AT sonhyecksoo quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades AT munrodonaldj quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades AT friedmannelfriede quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades AT auffarthgerdu quantificationoftheinvitropredispositiontoglisteningformationinonemanufacturersacrylicintraocularlensesmadeindifferentdecades |