Cargando…

Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry for Simultaneous Determination of Antipsychotic Drugs in Human Plasma and Its Application in Therapeutic Drug Monitoring

PURPOSE: We developed and validated an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for simultaneous therapeutic drug monitoring (TDM) and clinical pharmacokinetic antipsychotic drugs: clozapine (CLP), chlorpromazine (CPZ), risperidone (RPD), paliperidone (PLD...

Descripción completa

Detalles Bibliográficos
Autores principales: Qi, Yingjie, Liu, Guangxuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7887337/
https://www.ncbi.nlm.nih.gov/pubmed/33613026
http://dx.doi.org/10.2147/DDDT.S290963
_version_ 1783651960378884096
author Qi, Yingjie
Liu, Guangxuan
author_facet Qi, Yingjie
Liu, Guangxuan
author_sort Qi, Yingjie
collection PubMed
description PURPOSE: We developed and validated an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for simultaneous therapeutic drug monitoring (TDM) and clinical pharmacokinetic antipsychotic drugs: clozapine (CLP), chlorpromazine (CPZ), risperidone (RPD), paliperidone (PLD), quetiapine (QTP;), aripiprazole (APZ), dehydroaripiprazole (DAP), olanzapine (OZP), ziprasidone (ZRD), and amisulpride (ASP). METHODS: Analytes and internal standards (ISs) were separated using a Phenomenex phenyl-hexyl column (50.0 × 2.1 mm, 1.7 μm) with water containing 0.1% formic acid and 2 mM ammonium acetate, and methanol containing 0.1% formic acid and 2 mM ammonium acetate as the mobile phase. The antipsychotic drugs and ISs were extracted from 50 μL of plasma using acetonitrile. RESULTS: The calibration ranges were 25.0–1500.0 ng/mL for CLP, CPZ, DAP, and QTP, 10.0–600.0 ng/mL for CPZ and ZRD, 2.5–150.0 ng/mL for RPD, 5.0–300.0 ng/mL for PLD and OZP, and 20.0–1200.0 ng/mL for ASP. Validation was carried out according to the guidelines for bioanalytical validation, including assessment of calibration curves, specificity, accuracy, precision, recovery, stability, dilution integrity, and matrix effect. All the results satisfied the requirements. CONCLUSION: The results provided significant information to support future clinical TDM and rational drug use research. The proposed method also provided a simple, reliable, specific, and suitable technique for TDM and pharmacokinetic studies.
format Online
Article
Text
id pubmed-7887337
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-78873372021-02-18 Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry for Simultaneous Determination of Antipsychotic Drugs in Human Plasma and Its Application in Therapeutic Drug Monitoring Qi, Yingjie Liu, Guangxuan Drug Des Devel Ther Original Research PURPOSE: We developed and validated an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for simultaneous therapeutic drug monitoring (TDM) and clinical pharmacokinetic antipsychotic drugs: clozapine (CLP), chlorpromazine (CPZ), risperidone (RPD), paliperidone (PLD), quetiapine (QTP;), aripiprazole (APZ), dehydroaripiprazole (DAP), olanzapine (OZP), ziprasidone (ZRD), and amisulpride (ASP). METHODS: Analytes and internal standards (ISs) were separated using a Phenomenex phenyl-hexyl column (50.0 × 2.1 mm, 1.7 μm) with water containing 0.1% formic acid and 2 mM ammonium acetate, and methanol containing 0.1% formic acid and 2 mM ammonium acetate as the mobile phase. The antipsychotic drugs and ISs were extracted from 50 μL of plasma using acetonitrile. RESULTS: The calibration ranges were 25.0–1500.0 ng/mL for CLP, CPZ, DAP, and QTP, 10.0–600.0 ng/mL for CPZ and ZRD, 2.5–150.0 ng/mL for RPD, 5.0–300.0 ng/mL for PLD and OZP, and 20.0–1200.0 ng/mL for ASP. Validation was carried out according to the guidelines for bioanalytical validation, including assessment of calibration curves, specificity, accuracy, precision, recovery, stability, dilution integrity, and matrix effect. All the results satisfied the requirements. CONCLUSION: The results provided significant information to support future clinical TDM and rational drug use research. The proposed method also provided a simple, reliable, specific, and suitable technique for TDM and pharmacokinetic studies. Dove 2021-02-12 /pmc/articles/PMC7887337/ /pubmed/33613026 http://dx.doi.org/10.2147/DDDT.S290963 Text en © 2021 Qi and Liu. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Qi, Yingjie
Liu, Guangxuan
Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry for Simultaneous Determination of Antipsychotic Drugs in Human Plasma and Its Application in Therapeutic Drug Monitoring
title Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry for Simultaneous Determination of Antipsychotic Drugs in Human Plasma and Its Application in Therapeutic Drug Monitoring
title_full Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry for Simultaneous Determination of Antipsychotic Drugs in Human Plasma and Its Application in Therapeutic Drug Monitoring
title_fullStr Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry for Simultaneous Determination of Antipsychotic Drugs in Human Plasma and Its Application in Therapeutic Drug Monitoring
title_full_unstemmed Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry for Simultaneous Determination of Antipsychotic Drugs in Human Plasma and Its Application in Therapeutic Drug Monitoring
title_short Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry for Simultaneous Determination of Antipsychotic Drugs in Human Plasma and Its Application in Therapeutic Drug Monitoring
title_sort ultra-performance liquid chromatography-tandem mass spectrometry for simultaneous determination of antipsychotic drugs in human plasma and its application in therapeutic drug monitoring
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7887337/
https://www.ncbi.nlm.nih.gov/pubmed/33613026
http://dx.doi.org/10.2147/DDDT.S290963
work_keys_str_mv AT qiyingjie ultraperformanceliquidchromatographytandemmassspectrometryforsimultaneousdeterminationofantipsychoticdrugsinhumanplasmaanditsapplicationintherapeuticdrugmonitoring
AT liuguangxuan ultraperformanceliquidchromatographytandemmassspectrometryforsimultaneousdeterminationofantipsychoticdrugsinhumanplasmaanditsapplicationintherapeuticdrugmonitoring