Impact of Mobile Cloud Electrocardiography System on Door-to-Balloon Time in Patients With Acute Coronary Syndrome in Oita Prefecture

Background: The mobile cloud electrocardiography (C-ECG) system is useful for reducing door-to-balloon (DTB) time in patients with acute coronary syndrome (ACS), but few studies have reported the usefulness of the C-ECG system across a wide provincial prefecture, such as Oita, in Japan. Methods and ...

Descripción completa

Detalles Bibliográficos
Autores principales: Yufu, Kunio, Shimomura, Tsuyoshi, Fujinami, Mami, Nakashima, Tatsunori, Saito, Shotaro, Ayabe, Reika, Kawano, Kyoko, Ishii, Yumi, Okada, Norihiro, Akioka, Hidefumi, Teshima, Yasushi, Sakamoto, Teruo, Nakagawa, Mikiko, Takahashi, Naohiko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japanese Circulation Society 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7889482/
https://www.ncbi.nlm.nih.gov/pubmed/33693145
http://dx.doi.org/10.1253/circrep.CR-19-0020
_version_ 1783652319031721984
author Yufu, Kunio
Shimomura, Tsuyoshi
Fujinami, Mami
Nakashima, Tatsunori
Saito, Shotaro
Ayabe, Reika
Kawano, Kyoko
Ishii, Yumi
Okada, Norihiro
Akioka, Hidefumi
Teshima, Yasushi
Sakamoto, Teruo
Nakagawa, Mikiko
Takahashi, Naohiko
author_facet Yufu, Kunio
Shimomura, Tsuyoshi
Fujinami, Mami
Nakashima, Tatsunori
Saito, Shotaro
Ayabe, Reika
Kawano, Kyoko
Ishii, Yumi
Okada, Norihiro
Akioka, Hidefumi
Teshima, Yasushi
Sakamoto, Teruo
Nakagawa, Mikiko
Takahashi, Naohiko
author_sort Yufu, Kunio
collection PubMed
description Background: The mobile cloud electrocardiography (C-ECG) system is useful for reducing door-to-balloon (DTB) time in patients with acute coronary syndrome (ACS), but few studies have reported the usefulness of the C-ECG system across a wide provincial prefecture, such as Oita, in Japan. Methods and Results: On 17 April 2017, the C-ECG system was integrated into the Oita remote image transmission system, in 10 ambulances of 10 respective fire departments in Oita Prefecture. During 6 months, 162 ECG indicating suspected ACS were transmitted to 18 hospitals using the C-ECG system. Of 162 patients, 17 who received emergency percutaneous coronary intervention (PCI) were assigned to the cloud group (mean age, 71±11 years). The control group consisted of 29 consecutive ACS patients who were transported to Oita University Hospital without using the C-ECG system (mean age, 66±12 years). Another 40 consecutive patients were diagnosed with ACS before transportation to Oita University Hospital, and were assigned to the diagnosed group (mean age, 70±14 years). DTB time (70±26 min vs. 96±24 min, P<0.005) and door-to-catheterization laboratory time (33±20 min vs. 53±22 min, P<0.0001) were shorter in the cloud group than in the control group, respectively. Conclusions: C-ECG system integration in Oita Prefecture was useful to appropriately transfer ACS patients to hospital and to facilitate earlier PCI than in the conventional diagnostic system.
format Online
Article
Text
id pubmed-7889482
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Japanese Circulation Society
record_format MEDLINE/PubMed
spelling pubmed-78894822021-03-09 Impact of Mobile Cloud Electrocardiography System on Door-to-Balloon Time in Patients With Acute Coronary Syndrome in Oita Prefecture Yufu, Kunio Shimomura, Tsuyoshi Fujinami, Mami Nakashima, Tatsunori Saito, Shotaro Ayabe, Reika Kawano, Kyoko Ishii, Yumi Okada, Norihiro Akioka, Hidefumi Teshima, Yasushi Sakamoto, Teruo Nakagawa, Mikiko Takahashi, Naohiko Circ Rep Original article Background: The mobile cloud electrocardiography (C-ECG) system is useful for reducing door-to-balloon (DTB) time in patients with acute coronary syndrome (ACS), but few studies have reported the usefulness of the C-ECG system across a wide provincial prefecture, such as Oita, in Japan. Methods and Results: On 17 April 2017, the C-ECG system was integrated into the Oita remote image transmission system, in 10 ambulances of 10 respective fire departments in Oita Prefecture. During 6 months, 162 ECG indicating suspected ACS were transmitted to 18 hospitals using the C-ECG system. Of 162 patients, 17 who received emergency percutaneous coronary intervention (PCI) were assigned to the cloud group (mean age, 71±11 years). The control group consisted of 29 consecutive ACS patients who were transported to Oita University Hospital without using the C-ECG system (mean age, 66±12 years). Another 40 consecutive patients were diagnosed with ACS before transportation to Oita University Hospital, and were assigned to the diagnosed group (mean age, 70±14 years). DTB time (70±26 min vs. 96±24 min, P<0.005) and door-to-catheterization laboratory time (33±20 min vs. 53±22 min, P<0.0001) were shorter in the cloud group than in the control group, respectively. Conclusions: C-ECG system integration in Oita Prefecture was useful to appropriately transfer ACS patients to hospital and to facilitate earlier PCI than in the conventional diagnostic system. The Japanese Circulation Society 2019-05-31 /pmc/articles/PMC7889482/ /pubmed/33693145 http://dx.doi.org/10.1253/circrep.CR-19-0020 Text en Copyright © 2019, THE JAPANESE CIRCULATION SOCIETY This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.https://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Original article
Yufu, Kunio
Shimomura, Tsuyoshi
Fujinami, Mami
Nakashima, Tatsunori
Saito, Shotaro
Ayabe, Reika
Kawano, Kyoko
Ishii, Yumi
Okada, Norihiro
Akioka, Hidefumi
Teshima, Yasushi
Sakamoto, Teruo
Nakagawa, Mikiko
Takahashi, Naohiko
Impact of Mobile Cloud Electrocardiography System on Door-to-Balloon Time in Patients With Acute Coronary Syndrome in Oita Prefecture
title Impact of Mobile Cloud Electrocardiography System on Door-to-Balloon Time in Patients With Acute Coronary Syndrome in Oita Prefecture
title_full Impact of Mobile Cloud Electrocardiography System on Door-to-Balloon Time in Patients With Acute Coronary Syndrome in Oita Prefecture
title_fullStr Impact of Mobile Cloud Electrocardiography System on Door-to-Balloon Time in Patients With Acute Coronary Syndrome in Oita Prefecture
title_full_unstemmed Impact of Mobile Cloud Electrocardiography System on Door-to-Balloon Time in Patients With Acute Coronary Syndrome in Oita Prefecture
title_short Impact of Mobile Cloud Electrocardiography System on Door-to-Balloon Time in Patients With Acute Coronary Syndrome in Oita Prefecture
title_sort impact of mobile cloud electrocardiography system on door-to-balloon time in patients with acute coronary syndrome in oita prefecture
topic Original article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7889482/
https://www.ncbi.nlm.nih.gov/pubmed/33693145
http://dx.doi.org/10.1253/circrep.CR-19-0020
work_keys_str_mv AT yufukunio impactofmobilecloudelectrocardiographysystemondoortoballoontimeinpatientswithacutecoronarysyndromeinoitaprefecture
AT shimomuratsuyoshi impactofmobilecloudelectrocardiographysystemondoortoballoontimeinpatientswithacutecoronarysyndromeinoitaprefecture
AT fujinamimami impactofmobilecloudelectrocardiographysystemondoortoballoontimeinpatientswithacutecoronarysyndromeinoitaprefecture
AT nakashimatatsunori impactofmobilecloudelectrocardiographysystemondoortoballoontimeinpatientswithacutecoronarysyndromeinoitaprefecture
AT saitoshotaro impactofmobilecloudelectrocardiographysystemondoortoballoontimeinpatientswithacutecoronarysyndromeinoitaprefecture
AT ayabereika impactofmobilecloudelectrocardiographysystemondoortoballoontimeinpatientswithacutecoronarysyndromeinoitaprefecture
AT kawanokyoko impactofmobilecloudelectrocardiographysystemondoortoballoontimeinpatientswithacutecoronarysyndromeinoitaprefecture
AT ishiiyumi impactofmobilecloudelectrocardiographysystemondoortoballoontimeinpatientswithacutecoronarysyndromeinoitaprefecture
AT okadanorihiro impactofmobilecloudelectrocardiographysystemondoortoballoontimeinpatientswithacutecoronarysyndromeinoitaprefecture
AT akiokahidefumi impactofmobilecloudelectrocardiographysystemondoortoballoontimeinpatientswithacutecoronarysyndromeinoitaprefecture
AT teshimayasushi impactofmobilecloudelectrocardiographysystemondoortoballoontimeinpatientswithacutecoronarysyndromeinoitaprefecture
AT sakamototeruo impactofmobilecloudelectrocardiographysystemondoortoballoontimeinpatientswithacutecoronarysyndromeinoitaprefecture
AT nakagawamikiko impactofmobilecloudelectrocardiographysystemondoortoballoontimeinpatientswithacutecoronarysyndromeinoitaprefecture
AT takahashinaohiko impactofmobilecloudelectrocardiographysystemondoortoballoontimeinpatientswithacutecoronarysyndromeinoitaprefecture