Cargando…
A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside
This review presents an overview of previously reported non-invasive intra-abdominal pressure (IAP) measurement techniques. Each section covers the basic physical principles and methodology of the various measurement techniques, the experimental results, and the advantages and disadvantages of each...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Netherlands
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7889558/ https://www.ncbi.nlm.nih.gov/pubmed/32700152 http://dx.doi.org/10.1007/s10877-020-00561-4 |
_version_ | 1783652336311205888 |
---|---|
author | Tayebi, Salar Gutierrez, Adrian Mohout, Ikram Smets, Evelien Wise, Robert Stiens, Johan Malbrain, Manu L. N. G. |
author_facet | Tayebi, Salar Gutierrez, Adrian Mohout, Ikram Smets, Evelien Wise, Robert Stiens, Johan Malbrain, Manu L. N. G. |
author_sort | Tayebi, Salar |
collection | PubMed |
description | This review presents an overview of previously reported non-invasive intra-abdominal pressure (IAP) measurement techniques. Each section covers the basic physical principles and methodology of the various measurement techniques, the experimental results, and the advantages and disadvantages of each method. The most promising non-invasive methods for IAP measurement are microwave reflectometry and ultrasound assessment, in combination with an applied external force. |
format | Online Article Text |
id | pubmed-7889558 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Springer Netherlands |
record_format | MEDLINE/PubMed |
spelling | pubmed-78895582021-03-03 A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside Tayebi, Salar Gutierrez, Adrian Mohout, Ikram Smets, Evelien Wise, Robert Stiens, Johan Malbrain, Manu L. N. G. J Clin Monit Comput Review Paper This review presents an overview of previously reported non-invasive intra-abdominal pressure (IAP) measurement techniques. Each section covers the basic physical principles and methodology of the various measurement techniques, the experimental results, and the advantages and disadvantages of each method. The most promising non-invasive methods for IAP measurement are microwave reflectometry and ultrasound assessment, in combination with an applied external force. Springer Netherlands 2020-07-22 2021 /pmc/articles/PMC7889558/ /pubmed/32700152 http://dx.doi.org/10.1007/s10877-020-00561-4 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Review Paper Tayebi, Salar Gutierrez, Adrian Mohout, Ikram Smets, Evelien Wise, Robert Stiens, Johan Malbrain, Manu L. N. G. A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside |
title | A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside |
title_full | A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside |
title_fullStr | A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside |
title_full_unstemmed | A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside |
title_short | A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside |
title_sort | concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside |
topic | Review Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7889558/ https://www.ncbi.nlm.nih.gov/pubmed/32700152 http://dx.doi.org/10.1007/s10877-020-00561-4 |
work_keys_str_mv | AT tayebisalar aconciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside AT gutierrezadrian aconciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside AT mohoutikram aconciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside AT smetsevelien aconciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside AT wiserobert aconciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside AT stiensjohan aconciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside AT malbrainmanulng aconciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside AT tayebisalar conciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside AT gutierrezadrian conciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside AT mohoutikram conciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside AT smetsevelien conciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside AT wiserobert conciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside AT stiensjohan conciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside AT malbrainmanulng conciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside |