Cargando…

A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside

This review presents an overview of previously reported non-invasive intra-abdominal pressure (IAP) measurement techniques. Each section covers the basic physical principles and methodology of the various measurement techniques, the experimental results, and the advantages and disadvantages of each...

Descripción completa

Detalles Bibliográficos
Autores principales: Tayebi, Salar, Gutierrez, Adrian, Mohout, Ikram, Smets, Evelien, Wise, Robert, Stiens, Johan, Malbrain, Manu L. N. G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7889558/
https://www.ncbi.nlm.nih.gov/pubmed/32700152
http://dx.doi.org/10.1007/s10877-020-00561-4
_version_ 1783652336311205888
author Tayebi, Salar
Gutierrez, Adrian
Mohout, Ikram
Smets, Evelien
Wise, Robert
Stiens, Johan
Malbrain, Manu L. N. G.
author_facet Tayebi, Salar
Gutierrez, Adrian
Mohout, Ikram
Smets, Evelien
Wise, Robert
Stiens, Johan
Malbrain, Manu L. N. G.
author_sort Tayebi, Salar
collection PubMed
description This review presents an overview of previously reported non-invasive intra-abdominal pressure (IAP) measurement techniques. Each section covers the basic physical principles and methodology of the various measurement techniques, the experimental results, and the advantages and disadvantages of each method. The most promising non-invasive methods for IAP measurement are microwave reflectometry and ultrasound assessment, in combination with an applied external force.
format Online
Article
Text
id pubmed-7889558
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-78895582021-03-03 A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside Tayebi, Salar Gutierrez, Adrian Mohout, Ikram Smets, Evelien Wise, Robert Stiens, Johan Malbrain, Manu L. N. G. J Clin Monit Comput Review Paper This review presents an overview of previously reported non-invasive intra-abdominal pressure (IAP) measurement techniques. Each section covers the basic physical principles and methodology of the various measurement techniques, the experimental results, and the advantages and disadvantages of each method. The most promising non-invasive methods for IAP measurement are microwave reflectometry and ultrasound assessment, in combination with an applied external force. Springer Netherlands 2020-07-22 2021 /pmc/articles/PMC7889558/ /pubmed/32700152 http://dx.doi.org/10.1007/s10877-020-00561-4 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Review Paper
Tayebi, Salar
Gutierrez, Adrian
Mohout, Ikram
Smets, Evelien
Wise, Robert
Stiens, Johan
Malbrain, Manu L. N. G.
A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside
title A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside
title_full A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside
title_fullStr A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside
title_full_unstemmed A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside
title_short A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside
title_sort concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside
topic Review Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7889558/
https://www.ncbi.nlm.nih.gov/pubmed/32700152
http://dx.doi.org/10.1007/s10877-020-00561-4
work_keys_str_mv AT tayebisalar aconciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside
AT gutierrezadrian aconciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside
AT mohoutikram aconciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside
AT smetsevelien aconciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside
AT wiserobert aconciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside
AT stiensjohan aconciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside
AT malbrainmanulng aconciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside
AT tayebisalar conciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside
AT gutierrezadrian conciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside
AT mohoutikram conciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside
AT smetsevelien conciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside
AT wiserobert conciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside
AT stiensjohan conciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside
AT malbrainmanulng conciseoverviewofnoninvasiveintraabdominalpressuremeasurementtechniquesfrombenchtobedside