Cargando…

Successful transcatheter aortic valve implantation in a patient after an apico-aortic conduit for severe aortic stenosis complicated by haemolytic anaemia: a case report

BACKGROUND: Apico-aortic conduit (AAC) which connects the left ventricular (LV) apex directly to the descending aorta through a valved conduit, is an alternative to surgical aortic valve replacement (AVR) for patients with aortic stenosis (AS) who are inoperable or high risk for surgical AVR and are...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Kitae, Ehara, Natsuhiko, Koyama, Tadaaki, Furukawa, Yutaka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7891266/
https://www.ncbi.nlm.nih.gov/pubmed/33629010
http://dx.doi.org/10.1093/ehjcr/ytaa410
_version_ 1783652664372887552
author Kim, Kitae
Ehara, Natsuhiko
Koyama, Tadaaki
Furukawa, Yutaka
author_facet Kim, Kitae
Ehara, Natsuhiko
Koyama, Tadaaki
Furukawa, Yutaka
author_sort Kim, Kitae
collection PubMed
description BACKGROUND: Apico-aortic conduit (AAC) which connects the left ventricular (LV) apex directly to the descending aorta through a valved conduit, is an alternative to surgical aortic valve replacement (AVR) for patients with aortic stenosis (AS) who are inoperable or high risk for surgical AVR and are not suitable candidates for transcatheter aortic valve implantation (TAVI). CASE SUMMARY: An 84-year-old man with severe AS underwent an AAC combined with coronary artery bypass grafting 8 years earlier. A saphenous vein graft was anastomosed from the conduit to the left anterior descending artery. He had developed haemolytic anaemia requiring frequent blood transfusions. The stenosis at the anastomosis of the left ventricle and the conduit might be the cause of a turbulent flow and a shear stress which led to mechanical haemolysis. We expected that dilatation of native aortic valve would reduce the blood flow at the anastomosis site and thereby improve haemolytic anaemia. Since balloon aortic valvuloplasty improved haemolytic anaemia without exacerbation of myocardial ischaemia, transsubclavian TAVI was performed. After the TAVI, significant reductions in the pressure gradient between the left ventricle and the ascending aorta and that between the left ventricle and the conduit were achieved, and the patient remained clinically stable without the recurrence of haemolytic anaemia. DISCUSSION: This is the first report regarding mechanical haemolytic anaemia after AAC which might result from a turbulence and a shear stress by the stenosis of the anastomosis of the LV apex and the conduit. A careful monitoring for conduit dysfunction should be made after AAC.
format Online
Article
Text
id pubmed-7891266
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-78912662021-02-23 Successful transcatheter aortic valve implantation in a patient after an apico-aortic conduit for severe aortic stenosis complicated by haemolytic anaemia: a case report Kim, Kitae Ehara, Natsuhiko Koyama, Tadaaki Furukawa, Yutaka Eur Heart J Case Rep Case Reports BACKGROUND: Apico-aortic conduit (AAC) which connects the left ventricular (LV) apex directly to the descending aorta through a valved conduit, is an alternative to surgical aortic valve replacement (AVR) for patients with aortic stenosis (AS) who are inoperable or high risk for surgical AVR and are not suitable candidates for transcatheter aortic valve implantation (TAVI). CASE SUMMARY: An 84-year-old man with severe AS underwent an AAC combined with coronary artery bypass grafting 8 years earlier. A saphenous vein graft was anastomosed from the conduit to the left anterior descending artery. He had developed haemolytic anaemia requiring frequent blood transfusions. The stenosis at the anastomosis of the left ventricle and the conduit might be the cause of a turbulent flow and a shear stress which led to mechanical haemolysis. We expected that dilatation of native aortic valve would reduce the blood flow at the anastomosis site and thereby improve haemolytic anaemia. Since balloon aortic valvuloplasty improved haemolytic anaemia without exacerbation of myocardial ischaemia, transsubclavian TAVI was performed. After the TAVI, significant reductions in the pressure gradient between the left ventricle and the ascending aorta and that between the left ventricle and the conduit were achieved, and the patient remained clinically stable without the recurrence of haemolytic anaemia. DISCUSSION: This is the first report regarding mechanical haemolytic anaemia after AAC which might result from a turbulence and a shear stress by the stenosis of the anastomosis of the LV apex and the conduit. A careful monitoring for conduit dysfunction should be made after AAC. Oxford University Press 2020-11-12 /pmc/articles/PMC7891266/ /pubmed/33629010 http://dx.doi.org/10.1093/ehjcr/ytaa410 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of the European Society of Cardiology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Reports
Kim, Kitae
Ehara, Natsuhiko
Koyama, Tadaaki
Furukawa, Yutaka
Successful transcatheter aortic valve implantation in a patient after an apico-aortic conduit for severe aortic stenosis complicated by haemolytic anaemia: a case report
title Successful transcatheter aortic valve implantation in a patient after an apico-aortic conduit for severe aortic stenosis complicated by haemolytic anaemia: a case report
title_full Successful transcatheter aortic valve implantation in a patient after an apico-aortic conduit for severe aortic stenosis complicated by haemolytic anaemia: a case report
title_fullStr Successful transcatheter aortic valve implantation in a patient after an apico-aortic conduit for severe aortic stenosis complicated by haemolytic anaemia: a case report
title_full_unstemmed Successful transcatheter aortic valve implantation in a patient after an apico-aortic conduit for severe aortic stenosis complicated by haemolytic anaemia: a case report
title_short Successful transcatheter aortic valve implantation in a patient after an apico-aortic conduit for severe aortic stenosis complicated by haemolytic anaemia: a case report
title_sort successful transcatheter aortic valve implantation in a patient after an apico-aortic conduit for severe aortic stenosis complicated by haemolytic anaemia: a case report
topic Case Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7891266/
https://www.ncbi.nlm.nih.gov/pubmed/33629010
http://dx.doi.org/10.1093/ehjcr/ytaa410
work_keys_str_mv AT kimkitae successfultranscatheteraorticvalveimplantationinapatientafteranapicoaorticconduitforsevereaorticstenosiscomplicatedbyhaemolyticanaemiaacasereport
AT eharanatsuhiko successfultranscatheteraorticvalveimplantationinapatientafteranapicoaorticconduitforsevereaorticstenosiscomplicatedbyhaemolyticanaemiaacasereport
AT koyamatadaaki successfultranscatheteraorticvalveimplantationinapatientafteranapicoaorticconduitforsevereaorticstenosiscomplicatedbyhaemolyticanaemiaacasereport
AT furukawayutaka successfultranscatheteraorticvalveimplantationinapatientafteranapicoaorticconduitforsevereaorticstenosiscomplicatedbyhaemolyticanaemiaacasereport