Detection of atrial fibrillation with implantable loop recorders in horses

BACKGROUND: Cardiac arrhythmias in horses are diagnosed by auscultation or electrocardiogram (ECG), which results in a low sensitivity for detecting arrhythmias that occur sporadically. Implantable loop recorders (ILRs) are small ECG devices placed subcutaneously, to automatically detect arrhythmias...

Descripción completa

Detalles Bibliográficos
Autores principales: Buhl, Rikke, Hesselkilde, Eva M., Carstensen, Helena, Fenner, Merle F., Jespersen, Thomas, Tfelt‐Hansen, Jacob, Michael Sattler, Stefan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7891449/
https://www.ncbi.nlm.nih.gov/pubmed/32506470
http://dx.doi.org/10.1111/evj.13301
_version_ 1783652702413127680
author Buhl, Rikke
Hesselkilde, Eva M.
Carstensen, Helena
Fenner, Merle F.
Jespersen, Thomas
Tfelt‐Hansen, Jacob
Michael Sattler, Stefan
author_facet Buhl, Rikke
Hesselkilde, Eva M.
Carstensen, Helena
Fenner, Merle F.
Jespersen, Thomas
Tfelt‐Hansen, Jacob
Michael Sattler, Stefan
author_sort Buhl, Rikke
collection PubMed
description BACKGROUND: Cardiac arrhythmias in horses are diagnosed by auscultation or electrocardiogram (ECG), which results in a low sensitivity for detecting arrhythmias that occur sporadically. Implantable loop recorders (ILRs) are small ECG devices placed subcutaneously, to automatically detect arrhythmias in human patients. OBJECTIVES: To test ILRs ability to detect atrial fibrillation (AF) in horses. Furthermore, we hypothesised that anatomical location of the implant site might influence signal quality. Signal quality was evaluated both during exercise and over time. STUDY DESIGN: Experimental study. METHODS: In five Standardbred mares, eleven ILRs were implanted subcutaneously in up to three different positions (Front: pectoral region, Left‐6: sixth left intercostal space and Ventral: xiphoid region) and AF induced. The R‐ and T‐wave amplitudes were measured in all positions over time during AF. AF burden automatically registered by the ILRs over a 2‐month period was compared with selected Holter ECG recordings. RESULTS: All three positions had stable R‐ and T‐wave amplitudes during the study period and were of sufficient quality to allow AF detection at rest. The position Left‐6 showed significantly higher R‐ and T‐wave amplitudes compared with the other positions. During submaximal exercise only the Left‐6 position was able to record ECG signals of diagnostic quality. No position yielded diagnostic signals at maximum exercise due to artefacts. MAIN LIMITATIONS: Few horses and ILRs included and no spontaneous AF episodes were studied. CONCLUSIONS: This preliminary study indicates that ILRs can be used for AF detection in horses, but the anatomical location is important for optimal ECG quality. Despite insufficient quality during exercise, ILRs were suitable for AF detection at rest. Therefore, the ILR may be a valuable diagnostic tool for detecting paroxysmal AF in horses.
format Online
Article
Text
id pubmed-7891449
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-78914492021-03-02 Detection of atrial fibrillation with implantable loop recorders in horses Buhl, Rikke Hesselkilde, Eva M. Carstensen, Helena Fenner, Merle F. Jespersen, Thomas Tfelt‐Hansen, Jacob Michael Sattler, Stefan Equine Vet J Technical Notes BACKGROUND: Cardiac arrhythmias in horses are diagnosed by auscultation or electrocardiogram (ECG), which results in a low sensitivity for detecting arrhythmias that occur sporadically. Implantable loop recorders (ILRs) are small ECG devices placed subcutaneously, to automatically detect arrhythmias in human patients. OBJECTIVES: To test ILRs ability to detect atrial fibrillation (AF) in horses. Furthermore, we hypothesised that anatomical location of the implant site might influence signal quality. Signal quality was evaluated both during exercise and over time. STUDY DESIGN: Experimental study. METHODS: In five Standardbred mares, eleven ILRs were implanted subcutaneously in up to three different positions (Front: pectoral region, Left‐6: sixth left intercostal space and Ventral: xiphoid region) and AF induced. The R‐ and T‐wave amplitudes were measured in all positions over time during AF. AF burden automatically registered by the ILRs over a 2‐month period was compared with selected Holter ECG recordings. RESULTS: All three positions had stable R‐ and T‐wave amplitudes during the study period and were of sufficient quality to allow AF detection at rest. The position Left‐6 showed significantly higher R‐ and T‐wave amplitudes compared with the other positions. During submaximal exercise only the Left‐6 position was able to record ECG signals of diagnostic quality. No position yielded diagnostic signals at maximum exercise due to artefacts. MAIN LIMITATIONS: Few horses and ILRs included and no spontaneous AF episodes were studied. CONCLUSIONS: This preliminary study indicates that ILRs can be used for AF detection in horses, but the anatomical location is important for optimal ECG quality. Despite insufficient quality during exercise, ILRs were suitable for AF detection at rest. Therefore, the ILR may be a valuable diagnostic tool for detecting paroxysmal AF in horses. John Wiley and Sons Inc. 2020-06-28 2021-03 /pmc/articles/PMC7891449/ /pubmed/32506470 http://dx.doi.org/10.1111/evj.13301 Text en © 2020 The Authors. Equine Veterinary Journal published by John Wiley & Sons Ltd on behalf of EVJ Ltd This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Notes
Buhl, Rikke
Hesselkilde, Eva M.
Carstensen, Helena
Fenner, Merle F.
Jespersen, Thomas
Tfelt‐Hansen, Jacob
Michael Sattler, Stefan
Detection of atrial fibrillation with implantable loop recorders in horses
title Detection of atrial fibrillation with implantable loop recorders in horses
title_full Detection of atrial fibrillation with implantable loop recorders in horses
title_fullStr Detection of atrial fibrillation with implantable loop recorders in horses
title_full_unstemmed Detection of atrial fibrillation with implantable loop recorders in horses
title_short Detection of atrial fibrillation with implantable loop recorders in horses
title_sort detection of atrial fibrillation with implantable loop recorders in horses
topic Technical Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7891449/
https://www.ncbi.nlm.nih.gov/pubmed/32506470
http://dx.doi.org/10.1111/evj.13301
work_keys_str_mv AT buhlrikke detectionofatrialfibrillationwithimplantablelooprecordersinhorses
AT hesselkildeevam detectionofatrialfibrillationwithimplantablelooprecordersinhorses
AT carstensenhelena detectionofatrialfibrillationwithimplantablelooprecordersinhorses
AT fennermerlef detectionofatrialfibrillationwithimplantablelooprecordersinhorses
AT jespersenthomas detectionofatrialfibrillationwithimplantablelooprecordersinhorses
AT tfelthansenjacob detectionofatrialfibrillationwithimplantablelooprecordersinhorses
AT michaelsattlerstefan detectionofatrialfibrillationwithimplantablelooprecordersinhorses