Cargando…

Interpretation of the HLA epitopes—Continuous dilution method for detection of high‐titer IgG HLA antibody

BACKGROUND: The presence or absence of human leukocyte antigen (HLA) antibodies, especially the strength of donor‐specific HLA antibodies (DSAs), has important roles in clinical evaluation and diagnostic decision‐making for solid‐organ transplantation. Dilution patterns help to give a new sight of H...

Descripción completa

Detalles Bibliográficos
Autores principales: Xiao, Yanli, Liu, Wei, Kang, Zhongyu, Li, Daihong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7891501/
https://www.ncbi.nlm.nih.gov/pubmed/33283328
http://dx.doi.org/10.1002/jcla.23632
_version_ 1783652711566147584
author Xiao, Yanli
Liu, Wei
Kang, Zhongyu
Li, Daihong
author_facet Xiao, Yanli
Liu, Wei
Kang, Zhongyu
Li, Daihong
author_sort Xiao, Yanli
collection PubMed
description BACKGROUND: The presence or absence of human leukocyte antigen (HLA) antibodies, especially the strength of donor‐specific HLA antibodies (DSAs), has important roles in clinical evaluation and diagnostic decision‐making for solid‐organ transplantation. Dilution patterns help to give a new sight of HLA epitopes. “Epitope matching” is likely to lower the risk of developing DSA and increase the likelihood of matching a compatible donor. METHODS: We collected data evaluating HLA antibodies with a titration study using mean fluorescence intensity. RESULTS: Diluting the serum of recipients can reduce potential inhibitory effects, accurately evaluate the intensity of donor‐specific HLA antibodies, and guide surgeons to take or not take intervention measures. Dilution patterns also help to give a new sight of HLA epitopes. CONCLUSION: We believe that from the viewpoint of HLA antibodies, the dilution model can provide new tools and insights for the study of HLA epitopes.
format Online
Article
Text
id pubmed-7891501
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-78915012021-03-10 Interpretation of the HLA epitopes—Continuous dilution method for detection of high‐titer IgG HLA antibody Xiao, Yanli Liu, Wei Kang, Zhongyu Li, Daihong J Clin Lab Anal Case Report BACKGROUND: The presence or absence of human leukocyte antigen (HLA) antibodies, especially the strength of donor‐specific HLA antibodies (DSAs), has important roles in clinical evaluation and diagnostic decision‐making for solid‐organ transplantation. Dilution patterns help to give a new sight of HLA epitopes. “Epitope matching” is likely to lower the risk of developing DSA and increase the likelihood of matching a compatible donor. METHODS: We collected data evaluating HLA antibodies with a titration study using mean fluorescence intensity. RESULTS: Diluting the serum of recipients can reduce potential inhibitory effects, accurately evaluate the intensity of donor‐specific HLA antibodies, and guide surgeons to take or not take intervention measures. Dilution patterns also help to give a new sight of HLA epitopes. CONCLUSION: We believe that from the viewpoint of HLA antibodies, the dilution model can provide new tools and insights for the study of HLA epitopes. John Wiley and Sons Inc. 2020-12-01 /pmc/articles/PMC7891501/ /pubmed/33283328 http://dx.doi.org/10.1002/jcla.23632 Text en © 2020 The Authors. Journal of Clinical Laboratory Analysis published by Wiley Periodicals LLC This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Xiao, Yanli
Liu, Wei
Kang, Zhongyu
Li, Daihong
Interpretation of the HLA epitopes—Continuous dilution method for detection of high‐titer IgG HLA antibody
title Interpretation of the HLA epitopes—Continuous dilution method for detection of high‐titer IgG HLA antibody
title_full Interpretation of the HLA epitopes—Continuous dilution method for detection of high‐titer IgG HLA antibody
title_fullStr Interpretation of the HLA epitopes—Continuous dilution method for detection of high‐titer IgG HLA antibody
title_full_unstemmed Interpretation of the HLA epitopes—Continuous dilution method for detection of high‐titer IgG HLA antibody
title_short Interpretation of the HLA epitopes—Continuous dilution method for detection of high‐titer IgG HLA antibody
title_sort interpretation of the hla epitopes—continuous dilution method for detection of high‐titer igg hla antibody
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7891501/
https://www.ncbi.nlm.nih.gov/pubmed/33283328
http://dx.doi.org/10.1002/jcla.23632
work_keys_str_mv AT xiaoyanli interpretationofthehlaepitopescontinuousdilutionmethodfordetectionofhightiterigghlaantibody
AT liuwei interpretationofthehlaepitopescontinuousdilutionmethodfordetectionofhightiterigghlaantibody
AT kangzhongyu interpretationofthehlaepitopescontinuousdilutionmethodfordetectionofhightiterigghlaantibody
AT lidaihong interpretationofthehlaepitopescontinuousdilutionmethodfordetectionofhightiterigghlaantibody