Cargando…
Interpretation of the HLA epitopes—Continuous dilution method for detection of high‐titer IgG HLA antibody
BACKGROUND: The presence or absence of human leukocyte antigen (HLA) antibodies, especially the strength of donor‐specific HLA antibodies (DSAs), has important roles in clinical evaluation and diagnostic decision‐making for solid‐organ transplantation. Dilution patterns help to give a new sight of H...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7891501/ https://www.ncbi.nlm.nih.gov/pubmed/33283328 http://dx.doi.org/10.1002/jcla.23632 |
_version_ | 1783652711566147584 |
---|---|
author | Xiao, Yanli Liu, Wei Kang, Zhongyu Li, Daihong |
author_facet | Xiao, Yanli Liu, Wei Kang, Zhongyu Li, Daihong |
author_sort | Xiao, Yanli |
collection | PubMed |
description | BACKGROUND: The presence or absence of human leukocyte antigen (HLA) antibodies, especially the strength of donor‐specific HLA antibodies (DSAs), has important roles in clinical evaluation and diagnostic decision‐making for solid‐organ transplantation. Dilution patterns help to give a new sight of HLA epitopes. “Epitope matching” is likely to lower the risk of developing DSA and increase the likelihood of matching a compatible donor. METHODS: We collected data evaluating HLA antibodies with a titration study using mean fluorescence intensity. RESULTS: Diluting the serum of recipients can reduce potential inhibitory effects, accurately evaluate the intensity of donor‐specific HLA antibodies, and guide surgeons to take or not take intervention measures. Dilution patterns also help to give a new sight of HLA epitopes. CONCLUSION: We believe that from the viewpoint of HLA antibodies, the dilution model can provide new tools and insights for the study of HLA epitopes. |
format | Online Article Text |
id | pubmed-7891501 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-78915012021-03-10 Interpretation of the HLA epitopes—Continuous dilution method for detection of high‐titer IgG HLA antibody Xiao, Yanli Liu, Wei Kang, Zhongyu Li, Daihong J Clin Lab Anal Case Report BACKGROUND: The presence or absence of human leukocyte antigen (HLA) antibodies, especially the strength of donor‐specific HLA antibodies (DSAs), has important roles in clinical evaluation and diagnostic decision‐making for solid‐organ transplantation. Dilution patterns help to give a new sight of HLA epitopes. “Epitope matching” is likely to lower the risk of developing DSA and increase the likelihood of matching a compatible donor. METHODS: We collected data evaluating HLA antibodies with a titration study using mean fluorescence intensity. RESULTS: Diluting the serum of recipients can reduce potential inhibitory effects, accurately evaluate the intensity of donor‐specific HLA antibodies, and guide surgeons to take or not take intervention measures. Dilution patterns also help to give a new sight of HLA epitopes. CONCLUSION: We believe that from the viewpoint of HLA antibodies, the dilution model can provide new tools and insights for the study of HLA epitopes. John Wiley and Sons Inc. 2020-12-01 /pmc/articles/PMC7891501/ /pubmed/33283328 http://dx.doi.org/10.1002/jcla.23632 Text en © 2020 The Authors. Journal of Clinical Laboratory Analysis published by Wiley Periodicals LLC This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Xiao, Yanli Liu, Wei Kang, Zhongyu Li, Daihong Interpretation of the HLA epitopes—Continuous dilution method for detection of high‐titer IgG HLA antibody |
title | Interpretation of the HLA epitopes—Continuous dilution method for detection of high‐titer IgG HLA antibody |
title_full | Interpretation of the HLA epitopes—Continuous dilution method for detection of high‐titer IgG HLA antibody |
title_fullStr | Interpretation of the HLA epitopes—Continuous dilution method for detection of high‐titer IgG HLA antibody |
title_full_unstemmed | Interpretation of the HLA epitopes—Continuous dilution method for detection of high‐titer IgG HLA antibody |
title_short | Interpretation of the HLA epitopes—Continuous dilution method for detection of high‐titer IgG HLA antibody |
title_sort | interpretation of the hla epitopes—continuous dilution method for detection of high‐titer igg hla antibody |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7891501/ https://www.ncbi.nlm.nih.gov/pubmed/33283328 http://dx.doi.org/10.1002/jcla.23632 |
work_keys_str_mv | AT xiaoyanli interpretationofthehlaepitopescontinuousdilutionmethodfordetectionofhightiterigghlaantibody AT liuwei interpretationofthehlaepitopescontinuousdilutionmethodfordetectionofhightiterigghlaantibody AT kangzhongyu interpretationofthehlaepitopescontinuousdilutionmethodfordetectionofhightiterigghlaantibody AT lidaihong interpretationofthehlaepitopescontinuousdilutionmethodfordetectionofhightiterigghlaantibody |