Cargando…
Dosimetric and radiobiological comparison of treatment plan between CyberKnife and EDGE in stereotactic body radiotherapy for pancreatic cancer
To perform a comparison of the different stereotactic body radiotherapy (SBRT) plans between the Varian EDGE and CyberKnife (CK) systems for locally advanced unresectable pancreatic cancer. Fifteen patients with pancreatic cancer were selected in this study. The median planning target volume (PTV) w...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7893157/ https://www.ncbi.nlm.nih.gov/pubmed/33603030 http://dx.doi.org/10.1038/s41598-021-83648-5 |
_version_ | 1783653009274699776 |
---|---|
author | Dai, Zhi-tao Ma, Li Cao, Ting-ting Zhu, Lian Zhao, Man Li, Ning |
author_facet | Dai, Zhi-tao Ma, Li Cao, Ting-ting Zhu, Lian Zhao, Man Li, Ning |
author_sort | Dai, Zhi-tao |
collection | PubMed |
description | To perform a comparison of the different stereotactic body radiotherapy (SBRT) plans between the Varian EDGE and CyberKnife (CK) systems for locally advanced unresectable pancreatic cancer. Fifteen patients with pancreatic cancer were selected in this study. The median planning target volume (PTV) was 28.688 cm(3) (5.736–49.246 cm(3)). The SBRT plans for the EDGE and CK were generated in the Eclipse and Multiplan systems respectively with the same contouring and dose constrains for PTV and organs at risk (OARs). Dose distributions in PTV were evaluated in terms of coverage, conformity index (CI), new conformity index (nCI), homogeneity index (HI), and gradient index (GI). OARs, including spinal cord, bowel, stomach, duodenum and kidneys were statistically evaluated by different dose-volume metrics and equivalent uniform dose (EUD). The volume covered by the different isodose lines (ISDL) ranging from 10 to 100% for normal tissue were also analyzed. All SBRT plans for EDGE and CK met the dose constraints for PTV and OARs. For the PTV, the dosimetric metrics in EDGE plans were lower than that in CK, except that D(99) and GI were slightly higher. The EDGE plans with lower CI, nCI and HI were superior to generate more conformal and homogeneous dose distribution for PTV. For the normal tissue, the CK plans were better at OARs sparing. The radiobiological indices EUD of spinal cord, duodenum, stomach, and kidneys were lower for CK plans, except that liver were higher. The volumes of normal tissue covered by medium ISDLs (with range of 20–70%) were lower for CK plans while that covered by high and low ISDLs were lower for EDGE plans. This study indicated that both EDGE and CK generated equivalent plan quality, and both systems can be considered as beneficial techniques for SBRT of pancreatic cancer. EDGE plans offered more conformal and homogeneous dose distribution for PTV, while the CK plans could minimize the exposure of OARs. |
format | Online Article Text |
id | pubmed-7893157 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-78931572021-02-23 Dosimetric and radiobiological comparison of treatment plan between CyberKnife and EDGE in stereotactic body radiotherapy for pancreatic cancer Dai, Zhi-tao Ma, Li Cao, Ting-ting Zhu, Lian Zhao, Man Li, Ning Sci Rep Article To perform a comparison of the different stereotactic body radiotherapy (SBRT) plans between the Varian EDGE and CyberKnife (CK) systems for locally advanced unresectable pancreatic cancer. Fifteen patients with pancreatic cancer were selected in this study. The median planning target volume (PTV) was 28.688 cm(3) (5.736–49.246 cm(3)). The SBRT plans for the EDGE and CK were generated in the Eclipse and Multiplan systems respectively with the same contouring and dose constrains for PTV and organs at risk (OARs). Dose distributions in PTV were evaluated in terms of coverage, conformity index (CI), new conformity index (nCI), homogeneity index (HI), and gradient index (GI). OARs, including spinal cord, bowel, stomach, duodenum and kidneys were statistically evaluated by different dose-volume metrics and equivalent uniform dose (EUD). The volume covered by the different isodose lines (ISDL) ranging from 10 to 100% for normal tissue were also analyzed. All SBRT plans for EDGE and CK met the dose constraints for PTV and OARs. For the PTV, the dosimetric metrics in EDGE plans were lower than that in CK, except that D(99) and GI were slightly higher. The EDGE plans with lower CI, nCI and HI were superior to generate more conformal and homogeneous dose distribution for PTV. For the normal tissue, the CK plans were better at OARs sparing. The radiobiological indices EUD of spinal cord, duodenum, stomach, and kidneys were lower for CK plans, except that liver were higher. The volumes of normal tissue covered by medium ISDLs (with range of 20–70%) were lower for CK plans while that covered by high and low ISDLs were lower for EDGE plans. This study indicated that both EDGE and CK generated equivalent plan quality, and both systems can be considered as beneficial techniques for SBRT of pancreatic cancer. EDGE plans offered more conformal and homogeneous dose distribution for PTV, while the CK plans could minimize the exposure of OARs. Nature Publishing Group UK 2021-02-18 /pmc/articles/PMC7893157/ /pubmed/33603030 http://dx.doi.org/10.1038/s41598-021-83648-5 Text en © The Author(s) 2021 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Dai, Zhi-tao Ma, Li Cao, Ting-ting Zhu, Lian Zhao, Man Li, Ning Dosimetric and radiobiological comparison of treatment plan between CyberKnife and EDGE in stereotactic body radiotherapy for pancreatic cancer |
title | Dosimetric and radiobiological comparison of treatment plan between CyberKnife and EDGE in stereotactic body radiotherapy for pancreatic cancer |
title_full | Dosimetric and radiobiological comparison of treatment plan between CyberKnife and EDGE in stereotactic body radiotherapy for pancreatic cancer |
title_fullStr | Dosimetric and radiobiological comparison of treatment plan between CyberKnife and EDGE in stereotactic body radiotherapy for pancreatic cancer |
title_full_unstemmed | Dosimetric and radiobiological comparison of treatment plan between CyberKnife and EDGE in stereotactic body radiotherapy for pancreatic cancer |
title_short | Dosimetric and radiobiological comparison of treatment plan between CyberKnife and EDGE in stereotactic body radiotherapy for pancreatic cancer |
title_sort | dosimetric and radiobiological comparison of treatment plan between cyberknife and edge in stereotactic body radiotherapy for pancreatic cancer |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7893157/ https://www.ncbi.nlm.nih.gov/pubmed/33603030 http://dx.doi.org/10.1038/s41598-021-83648-5 |
work_keys_str_mv | AT daizhitao dosimetricandradiobiologicalcomparisonoftreatmentplanbetweencyberknifeandedgeinstereotacticbodyradiotherapyforpancreaticcancer AT mali dosimetricandradiobiologicalcomparisonoftreatmentplanbetweencyberknifeandedgeinstereotacticbodyradiotherapyforpancreaticcancer AT caotingting dosimetricandradiobiologicalcomparisonoftreatmentplanbetweencyberknifeandedgeinstereotacticbodyradiotherapyforpancreaticcancer AT zhulian dosimetricandradiobiologicalcomparisonoftreatmentplanbetweencyberknifeandedgeinstereotacticbodyradiotherapyforpancreaticcancer AT zhaoman dosimetricandradiobiologicalcomparisonoftreatmentplanbetweencyberknifeandedgeinstereotacticbodyradiotherapyforpancreaticcancer AT lining dosimetricandradiobiologicalcomparisonoftreatmentplanbetweencyberknifeandedgeinstereotacticbodyradiotherapyforpancreaticcancer |