Cargando…

Feasibility of continuous monitoring of vital signs in surgical patients on a general ward: an observational cohort study

OBJECTIVE: To determine feasibility, in terms of acceptability and system fidelity, of continuous vital signs monitoring in abdominal surgery patients on a general ward. DESIGN: Observational cohort study. SETTING: Tertiary teaching hospital. PARTICIPANTS: Postoperative abdominal surgical patients (...

Descripción completa

Detalles Bibliográficos
Autores principales: Leenen, Jobbe P L, Dijkman, Eline M, van Dijk, Joris D, van Westreenen, Henderik L, Kalkman, Cor, Schoonhoven, Lisette, Patijn, Gijsbert A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7893648/
https://www.ncbi.nlm.nih.gov/pubmed/33597138
http://dx.doi.org/10.1136/bmjopen-2020-042735
_version_ 1783653087159779328
author Leenen, Jobbe P L
Dijkman, Eline M
van Dijk, Joris D
van Westreenen, Henderik L
Kalkman, Cor
Schoonhoven, Lisette
Patijn, Gijsbert A
author_facet Leenen, Jobbe P L
Dijkman, Eline M
van Dijk, Joris D
van Westreenen, Henderik L
Kalkman, Cor
Schoonhoven, Lisette
Patijn, Gijsbert A
author_sort Leenen, Jobbe P L
collection PubMed
description OBJECTIVE: To determine feasibility, in terms of acceptability and system fidelity, of continuous vital signs monitoring in abdominal surgery patients on a general ward. DESIGN: Observational cohort study. SETTING: Tertiary teaching hospital. PARTICIPANTS: Postoperative abdominal surgical patients (n=30) and nurses (n=23). INTERVENTIONS: Patients were continuously monitored with the SensiumVitals wearable device until discharge in addition to usual care, which is intermittent Modified Early Warning Score measurements. Heart rate, respiratory rate and axillary temperature were monitored every 2 min. Values and trends were visualised and alerts sent to the nurses. OUTCOMES: System fidelity was measured by analysis of the monitoring data. Acceptability by patients and nurses was assessed using questionnaires. RESULTS: Thirty patients were monitored for a median duration of 81 hours (IQR 47–143) per patient, resulting in 115 217 measurements per parameter. In total, 19% (n=21 311) of heart rate, 51% (n=59 184) of respiratory rate and 9% of temperature measurements showed artefacts (n=10 269). The system algorithm sent 972 alerts (median alert rate of 4.5 per patient per day), of which 90.3% (n=878) were system alerts and 9.7% (n=94) were vital sign alerts. 35% (n=33) of vital sign alerts were true positives. 93% (n=25) of patients rated the patch as comfortable, 67% (n=18) felt safer and 89% (n=24) would like to wear it next time in the hospital. Nurses were neutral about usefulness, with a median score of 3.5 (IQR 3.1–4) on a 7-point Likert scale, ease of use 3.7 (IQR 3.2–4.8) and satisfaction 3.7 (IQR 3.2–4.8), but agreed on ease of learning at 5.0 (IQR 4.0–5.8). Neutral scores were mostly related to the perceived limited fidelity of the system. CONCLUSIONS: Continuous monitoring of vital signs with a wearable device was well accepted by patients. Nurses’ ratings were highly variable, resulting in on average neutral attitude towards remote monitoring. Our results suggest it is feasible to monitor vital signs continuously on general wards, although acceptability of the device among nurses needs further improvement.
format Online
Article
Text
id pubmed-7893648
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-78936482021-03-03 Feasibility of continuous monitoring of vital signs in surgical patients on a general ward: an observational cohort study Leenen, Jobbe P L Dijkman, Eline M van Dijk, Joris D van Westreenen, Henderik L Kalkman, Cor Schoonhoven, Lisette Patijn, Gijsbert A BMJ Open Nursing OBJECTIVE: To determine feasibility, in terms of acceptability and system fidelity, of continuous vital signs monitoring in abdominal surgery patients on a general ward. DESIGN: Observational cohort study. SETTING: Tertiary teaching hospital. PARTICIPANTS: Postoperative abdominal surgical patients (n=30) and nurses (n=23). INTERVENTIONS: Patients were continuously monitored with the SensiumVitals wearable device until discharge in addition to usual care, which is intermittent Modified Early Warning Score measurements. Heart rate, respiratory rate and axillary temperature were monitored every 2 min. Values and trends were visualised and alerts sent to the nurses. OUTCOMES: System fidelity was measured by analysis of the monitoring data. Acceptability by patients and nurses was assessed using questionnaires. RESULTS: Thirty patients were monitored for a median duration of 81 hours (IQR 47–143) per patient, resulting in 115 217 measurements per parameter. In total, 19% (n=21 311) of heart rate, 51% (n=59 184) of respiratory rate and 9% of temperature measurements showed artefacts (n=10 269). The system algorithm sent 972 alerts (median alert rate of 4.5 per patient per day), of which 90.3% (n=878) were system alerts and 9.7% (n=94) were vital sign alerts. 35% (n=33) of vital sign alerts were true positives. 93% (n=25) of patients rated the patch as comfortable, 67% (n=18) felt safer and 89% (n=24) would like to wear it next time in the hospital. Nurses were neutral about usefulness, with a median score of 3.5 (IQR 3.1–4) on a 7-point Likert scale, ease of use 3.7 (IQR 3.2–4.8) and satisfaction 3.7 (IQR 3.2–4.8), but agreed on ease of learning at 5.0 (IQR 4.0–5.8). Neutral scores were mostly related to the perceived limited fidelity of the system. CONCLUSIONS: Continuous monitoring of vital signs with a wearable device was well accepted by patients. Nurses’ ratings were highly variable, resulting in on average neutral attitude towards remote monitoring. Our results suggest it is feasible to monitor vital signs continuously on general wards, although acceptability of the device among nurses needs further improvement. BMJ Publishing Group 2021-02-17 /pmc/articles/PMC7893648/ /pubmed/33597138 http://dx.doi.org/10.1136/bmjopen-2020-042735 Text en © Author(s) (or their employer(s)) 2021. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. http://creativecommons.org/licenses/by-nc/4.0/ http://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.
spellingShingle Nursing
Leenen, Jobbe P L
Dijkman, Eline M
van Dijk, Joris D
van Westreenen, Henderik L
Kalkman, Cor
Schoonhoven, Lisette
Patijn, Gijsbert A
Feasibility of continuous monitoring of vital signs in surgical patients on a general ward: an observational cohort study
title Feasibility of continuous monitoring of vital signs in surgical patients on a general ward: an observational cohort study
title_full Feasibility of continuous monitoring of vital signs in surgical patients on a general ward: an observational cohort study
title_fullStr Feasibility of continuous monitoring of vital signs in surgical patients on a general ward: an observational cohort study
title_full_unstemmed Feasibility of continuous monitoring of vital signs in surgical patients on a general ward: an observational cohort study
title_short Feasibility of continuous monitoring of vital signs in surgical patients on a general ward: an observational cohort study
title_sort feasibility of continuous monitoring of vital signs in surgical patients on a general ward: an observational cohort study
topic Nursing
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7893648/
https://www.ncbi.nlm.nih.gov/pubmed/33597138
http://dx.doi.org/10.1136/bmjopen-2020-042735
work_keys_str_mv AT leenenjobbepl feasibilityofcontinuousmonitoringofvitalsignsinsurgicalpatientsonageneralwardanobservationalcohortstudy
AT dijkmanelinem feasibilityofcontinuousmonitoringofvitalsignsinsurgicalpatientsonageneralwardanobservationalcohortstudy
AT vandijkjorisd feasibilityofcontinuousmonitoringofvitalsignsinsurgicalpatientsonageneralwardanobservationalcohortstudy
AT vanwestreenenhenderikl feasibilityofcontinuousmonitoringofvitalsignsinsurgicalpatientsonageneralwardanobservationalcohortstudy
AT kalkmancor feasibilityofcontinuousmonitoringofvitalsignsinsurgicalpatientsonageneralwardanobservationalcohortstudy
AT schoonhovenlisette feasibilityofcontinuousmonitoringofvitalsignsinsurgicalpatientsonageneralwardanobservationalcohortstudy
AT patijngijsberta feasibilityofcontinuousmonitoringofvitalsignsinsurgicalpatientsonageneralwardanobservationalcohortstudy