Left intraventricular pressure gradient in hypertrophic cardiomyopathy patients receiving implantable cardioverter-defibrillators for primary prevention

BACKGROUND: Conventional risk factors for sudden cardiac death (SCD) justify primary prevention through implantable cardioverter-defibrillator (ICD) implantation in hypertrophic cardiomyopathy (HCM) patients. However, the positive predictive values for these conventional SCD risk factors are low. Le...

Descripción completa

Detalles Bibliográficos
Autores principales: Yazaki, Kyoichiro, Suzuki, Atsushi, Shiga, Tsuyoshi, Minami, Yuichiro, Arai, Kotaro, Ashihara, Kyomi, Shoda, Morio, Hagiwara, Nobuhisa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7893864/
https://www.ncbi.nlm.nih.gov/pubmed/33607967
http://dx.doi.org/10.1186/s12872-021-01910-0
_version_ 1783653132798001152
author Yazaki, Kyoichiro
Suzuki, Atsushi
Shiga, Tsuyoshi
Minami, Yuichiro
Arai, Kotaro
Ashihara, Kyomi
Shoda, Morio
Hagiwara, Nobuhisa
author_facet Yazaki, Kyoichiro
Suzuki, Atsushi
Shiga, Tsuyoshi
Minami, Yuichiro
Arai, Kotaro
Ashihara, Kyomi
Shoda, Morio
Hagiwara, Nobuhisa
author_sort Yazaki, Kyoichiro
collection PubMed
description BACKGROUND: Conventional risk factors for sudden cardiac death (SCD) justify primary prevention through implantable cardioverter-defibrillator (ICD) implantation in hypertrophic cardiomyopathy (HCM) patients. However, the positive predictive values for these conventional SCD risk factors are low. Left ventricular outflow tract obstruction (LVOTO) and midventricular obstruction (MVO) are potential risk modifiers for SCD. The aims of this study were to evaluate whether an elevated intraventricular pressure gradient (IVPG), including LVOTO or MVO, is a potential risk modifier for SCD and ventricular arrhythmias requiring ICD interventions in addition to the conventional risk factors among HCM patients receiving ICDs for primary prevention. METHODS: We retrospectively studied 60 HCM patients who received ICDs for primary prevention. An elevated IVPG was defined as a peak instantaneous gradient ≥ 30 mmHg at rest, as detected by continuous-wave Doppler echocardiography. The main outcome was a composite of SCD and appropriate ICD interventions, which were defined as an antitachycardia pacing or shock therapy for ventricular tachycardia or fibrillation. The Cox proportional hazards model was used to assess the relationships between risk factors and the occurrence of SCD and appropriate ICD interventions. RESULTS: Thirty patients met the criteria of elevated IVPG (50%). During the median follow-up period of 66 months, 2 patients experienced SCD, and 10 patients received appropriate ICD interventions. Kaplan–Meier curves showed that the incidence of the main outcome was higher in patients with an IVPG ≥ 30 mmHg than in those without an IVPG ≥ 30 mmHg (log-rank P = 0.03). There were no differences in the main outcome between patients with LVOTO and patients with MVO. The combination of nonsustained ventricular tachycardia (NSVT) and IVPG ≥ 30 mmHg was found to significantly increase the risk of the main outcome (HR 6.31, 95% CI 1.36–29.25, P = 0.02). Five patients experienced ICD implant-related complications. CONCLUSIONS: Our findings showed that a baseline IVPG ≥ 30 mmHg was associated with an increased risk of experiencing SCD or appropriate ICD interventions among HCM patients who received ICDs for primary prevention. Combined with NSVT, which is a conventional risk factor, a baseline IVPG ≥ 30 mmHg may be a potential modifier of SCD risk in HCM patients.
format Online
Article
Text
id pubmed-7893864
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-78938642021-02-22 Left intraventricular pressure gradient in hypertrophic cardiomyopathy patients receiving implantable cardioverter-defibrillators for primary prevention Yazaki, Kyoichiro Suzuki, Atsushi Shiga, Tsuyoshi Minami, Yuichiro Arai, Kotaro Ashihara, Kyomi Shoda, Morio Hagiwara, Nobuhisa BMC Cardiovasc Disord Research Article BACKGROUND: Conventional risk factors for sudden cardiac death (SCD) justify primary prevention through implantable cardioverter-defibrillator (ICD) implantation in hypertrophic cardiomyopathy (HCM) patients. However, the positive predictive values for these conventional SCD risk factors are low. Left ventricular outflow tract obstruction (LVOTO) and midventricular obstruction (MVO) are potential risk modifiers for SCD. The aims of this study were to evaluate whether an elevated intraventricular pressure gradient (IVPG), including LVOTO or MVO, is a potential risk modifier for SCD and ventricular arrhythmias requiring ICD interventions in addition to the conventional risk factors among HCM patients receiving ICDs for primary prevention. METHODS: We retrospectively studied 60 HCM patients who received ICDs for primary prevention. An elevated IVPG was defined as a peak instantaneous gradient ≥ 30 mmHg at rest, as detected by continuous-wave Doppler echocardiography. The main outcome was a composite of SCD and appropriate ICD interventions, which were defined as an antitachycardia pacing or shock therapy for ventricular tachycardia or fibrillation. The Cox proportional hazards model was used to assess the relationships between risk factors and the occurrence of SCD and appropriate ICD interventions. RESULTS: Thirty patients met the criteria of elevated IVPG (50%). During the median follow-up period of 66 months, 2 patients experienced SCD, and 10 patients received appropriate ICD interventions. Kaplan–Meier curves showed that the incidence of the main outcome was higher in patients with an IVPG ≥ 30 mmHg than in those without an IVPG ≥ 30 mmHg (log-rank P = 0.03). There were no differences in the main outcome between patients with LVOTO and patients with MVO. The combination of nonsustained ventricular tachycardia (NSVT) and IVPG ≥ 30 mmHg was found to significantly increase the risk of the main outcome (HR 6.31, 95% CI 1.36–29.25, P = 0.02). Five patients experienced ICD implant-related complications. CONCLUSIONS: Our findings showed that a baseline IVPG ≥ 30 mmHg was associated with an increased risk of experiencing SCD or appropriate ICD interventions among HCM patients who received ICDs for primary prevention. Combined with NSVT, which is a conventional risk factor, a baseline IVPG ≥ 30 mmHg may be a potential modifier of SCD risk in HCM patients. BioMed Central 2021-02-19 /pmc/articles/PMC7893864/ /pubmed/33607967 http://dx.doi.org/10.1186/s12872-021-01910-0 Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Yazaki, Kyoichiro
Suzuki, Atsushi
Shiga, Tsuyoshi
Minami, Yuichiro
Arai, Kotaro
Ashihara, Kyomi
Shoda, Morio
Hagiwara, Nobuhisa
Left intraventricular pressure gradient in hypertrophic cardiomyopathy patients receiving implantable cardioverter-defibrillators for primary prevention
title Left intraventricular pressure gradient in hypertrophic cardiomyopathy patients receiving implantable cardioverter-defibrillators for primary prevention
title_full Left intraventricular pressure gradient in hypertrophic cardiomyopathy patients receiving implantable cardioverter-defibrillators for primary prevention
title_fullStr Left intraventricular pressure gradient in hypertrophic cardiomyopathy patients receiving implantable cardioverter-defibrillators for primary prevention
title_full_unstemmed Left intraventricular pressure gradient in hypertrophic cardiomyopathy patients receiving implantable cardioverter-defibrillators for primary prevention
title_short Left intraventricular pressure gradient in hypertrophic cardiomyopathy patients receiving implantable cardioverter-defibrillators for primary prevention
title_sort left intraventricular pressure gradient in hypertrophic cardiomyopathy patients receiving implantable cardioverter-defibrillators for primary prevention
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7893864/
https://www.ncbi.nlm.nih.gov/pubmed/33607967
http://dx.doi.org/10.1186/s12872-021-01910-0
work_keys_str_mv AT yazakikyoichiro leftintraventricularpressuregradientinhypertrophiccardiomyopathypatientsreceivingimplantablecardioverterdefibrillatorsforprimaryprevention
AT suzukiatsushi leftintraventricularpressuregradientinhypertrophiccardiomyopathypatientsreceivingimplantablecardioverterdefibrillatorsforprimaryprevention
AT shigatsuyoshi leftintraventricularpressuregradientinhypertrophiccardiomyopathypatientsreceivingimplantablecardioverterdefibrillatorsforprimaryprevention
AT minamiyuichiro leftintraventricularpressuregradientinhypertrophiccardiomyopathypatientsreceivingimplantablecardioverterdefibrillatorsforprimaryprevention
AT araikotaro leftintraventricularpressuregradientinhypertrophiccardiomyopathypatientsreceivingimplantablecardioverterdefibrillatorsforprimaryprevention
AT ashiharakyomi leftintraventricularpressuregradientinhypertrophiccardiomyopathypatientsreceivingimplantablecardioverterdefibrillatorsforprimaryprevention
AT shodamorio leftintraventricularpressuregradientinhypertrophiccardiomyopathypatientsreceivingimplantablecardioverterdefibrillatorsforprimaryprevention
AT hagiwaranobuhisa leftintraventricularpressuregradientinhypertrophiccardiomyopathypatientsreceivingimplantablecardioverterdefibrillatorsforprimaryprevention