Accuracy of an MR-only workflow for prostate radiotherapy using semi-automatically burned-in fiducial markers
BACKGROUND: The benefit of MR-only workflow compared to current CT-based workflow for prostate radiotherapy is reduction of systematic errors in the radiotherapy chain by 2–3 mm. Nowadays, MRI is used for target delineation while CT is needed for position verification. In MR-only workflows, MRI base...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7893889/ https://www.ncbi.nlm.nih.gov/pubmed/33608008 http://dx.doi.org/10.1186/s13014-021-01768-8 |
_version_ | 1783653138199216128 |
---|---|
author | Goudschaal, Karin Beeksma, F. Boon, M. Bijveld, M. Visser, J. Hinnen, K. van Kesteren, Z. |
author_facet | Goudschaal, Karin Beeksma, F. Boon, M. Bijveld, M. Visser, J. Hinnen, K. van Kesteren, Z. |
author_sort | Goudschaal, Karin |
collection | PubMed |
description | BACKGROUND: The benefit of MR-only workflow compared to current CT-based workflow for prostate radiotherapy is reduction of systematic errors in the radiotherapy chain by 2–3 mm. Nowadays, MRI is used for target delineation while CT is needed for position verification. In MR-only workflows, MRI based synthetic CT (sCT) replaces CT. Intraprostatic fiducial markers (FMs) are used as a surrogate for the position of the prostate improving targeting. However, FMs are not visible on sCT. Therefore, a semi-automatic method for burning-in FMs on sCT was developed. Accuracy of MR-only workflow using semi-automatically burned-in FMs was assessed and compared to CT/MR workflow. METHODS: Thirty-one prostate cancer patients receiving radiotherapy, underwent an additional MR sequence (mDIXON) to create an sCT for MR-only workflow simulation. Three sources of accuracy in the CT/MR- and MR-only workflow were investigated. To compare image registrations for target delineation, the inter-observer error (IOE) of FM-based CT-to-MR image registrations and soft-tissue-based MR-to-MR image registrations were determined on twenty patients. Secondly, the inter-observer variation of the resulting FM positions was determined on twenty patients. Thirdly, on 26 patients CBCTs were retrospectively registered on sCT with burned-in FMs and compared to CT-CBCT registrations. RESULTS: Image registration for target delineation shows a three times smaller IOE for MR-only workflow compared to CT/MR workflow. All observers agreed in correctly identifying all FMs for 18 out of 20 patients (90%). The IOE in CC direction of the center of mass (COM) position of the markers was within the CT slice thickness (2.5 mm), the IOE in AP and RL direction were below 1.0 mm and 1.5 mm, respectively. Registrations for IGRT position verification in MR-only workflow compared to CT/MR workflow were equivalent in RL-, CC- and AP-direction, except for a significant difference for random error in rotation. CONCLUSIONS: MR-only workflow using sCT with burned-in FMs is an improvement compared to the current CT/MR workflow, with a three times smaller inter observer error in CT-MR registration and comparable CBCT registration results between CT and sCT reference scans. Trial registry Medical Research Involving Human Subjects Act (WMO) does apply to this study and was approved by the Medical Ethics review Committee of the Academic Medical Center. Registration number: NL65414.018.18. Date of registration: 21–08-2018. |
format | Online Article Text |
id | pubmed-7893889 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-78938892021-02-22 Accuracy of an MR-only workflow for prostate radiotherapy using semi-automatically burned-in fiducial markers Goudschaal, Karin Beeksma, F. Boon, M. Bijveld, M. Visser, J. Hinnen, K. van Kesteren, Z. Radiat Oncol Research BACKGROUND: The benefit of MR-only workflow compared to current CT-based workflow for prostate radiotherapy is reduction of systematic errors in the radiotherapy chain by 2–3 mm. Nowadays, MRI is used for target delineation while CT is needed for position verification. In MR-only workflows, MRI based synthetic CT (sCT) replaces CT. Intraprostatic fiducial markers (FMs) are used as a surrogate for the position of the prostate improving targeting. However, FMs are not visible on sCT. Therefore, a semi-automatic method for burning-in FMs on sCT was developed. Accuracy of MR-only workflow using semi-automatically burned-in FMs was assessed and compared to CT/MR workflow. METHODS: Thirty-one prostate cancer patients receiving radiotherapy, underwent an additional MR sequence (mDIXON) to create an sCT for MR-only workflow simulation. Three sources of accuracy in the CT/MR- and MR-only workflow were investigated. To compare image registrations for target delineation, the inter-observer error (IOE) of FM-based CT-to-MR image registrations and soft-tissue-based MR-to-MR image registrations were determined on twenty patients. Secondly, the inter-observer variation of the resulting FM positions was determined on twenty patients. Thirdly, on 26 patients CBCTs were retrospectively registered on sCT with burned-in FMs and compared to CT-CBCT registrations. RESULTS: Image registration for target delineation shows a three times smaller IOE for MR-only workflow compared to CT/MR workflow. All observers agreed in correctly identifying all FMs for 18 out of 20 patients (90%). The IOE in CC direction of the center of mass (COM) position of the markers was within the CT slice thickness (2.5 mm), the IOE in AP and RL direction were below 1.0 mm and 1.5 mm, respectively. Registrations for IGRT position verification in MR-only workflow compared to CT/MR workflow were equivalent in RL-, CC- and AP-direction, except for a significant difference for random error in rotation. CONCLUSIONS: MR-only workflow using sCT with burned-in FMs is an improvement compared to the current CT/MR workflow, with a three times smaller inter observer error in CT-MR registration and comparable CBCT registration results between CT and sCT reference scans. Trial registry Medical Research Involving Human Subjects Act (WMO) does apply to this study and was approved by the Medical Ethics review Committee of the Academic Medical Center. Registration number: NL65414.018.18. Date of registration: 21–08-2018. BioMed Central 2021-02-19 /pmc/articles/PMC7893889/ /pubmed/33608008 http://dx.doi.org/10.1186/s13014-021-01768-8 Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Goudschaal, Karin Beeksma, F. Boon, M. Bijveld, M. Visser, J. Hinnen, K. van Kesteren, Z. Accuracy of an MR-only workflow for prostate radiotherapy using semi-automatically burned-in fiducial markers |
title | Accuracy of an MR-only workflow for prostate radiotherapy using semi-automatically burned-in fiducial markers |
title_full | Accuracy of an MR-only workflow for prostate radiotherapy using semi-automatically burned-in fiducial markers |
title_fullStr | Accuracy of an MR-only workflow for prostate radiotherapy using semi-automatically burned-in fiducial markers |
title_full_unstemmed | Accuracy of an MR-only workflow for prostate radiotherapy using semi-automatically burned-in fiducial markers |
title_short | Accuracy of an MR-only workflow for prostate radiotherapy using semi-automatically burned-in fiducial markers |
title_sort | accuracy of an mr-only workflow for prostate radiotherapy using semi-automatically burned-in fiducial markers |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7893889/ https://www.ncbi.nlm.nih.gov/pubmed/33608008 http://dx.doi.org/10.1186/s13014-021-01768-8 |
work_keys_str_mv | AT goudschaalkarin accuracyofanmronlyworkflowforprostateradiotherapyusingsemiautomaticallyburnedinfiducialmarkers AT beeksmaf accuracyofanmronlyworkflowforprostateradiotherapyusingsemiautomaticallyburnedinfiducialmarkers AT boonm accuracyofanmronlyworkflowforprostateradiotherapyusingsemiautomaticallyburnedinfiducialmarkers AT bijveldm accuracyofanmronlyworkflowforprostateradiotherapyusingsemiautomaticallyburnedinfiducialmarkers AT visserj accuracyofanmronlyworkflowforprostateradiotherapyusingsemiautomaticallyburnedinfiducialmarkers AT hinnenk accuracyofanmronlyworkflowforprostateradiotherapyusingsemiautomaticallyburnedinfiducialmarkers AT vankesterenz accuracyofanmronlyworkflowforprostateradiotherapyusingsemiautomaticallyburnedinfiducialmarkers |