Cargando…
Direct comparison of multilayer left ventricular global longitudinal strain using CMR feature tracking and speckle tracking echocardiography
BACKGROUND: Cardiac magnetic resonance feature tracking (CMR-FT) and speckle tracking echocardiography (STE) are well-established strain imaging modalities. Multilayer strain measurement permits independent assessment of endocardial and epicardial strain. This novel and layer specific approach to ev...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7893897/ https://www.ncbi.nlm.nih.gov/pubmed/33607946 http://dx.doi.org/10.1186/s12872-021-01916-8 |
_version_ | 1783653139833946112 |
---|---|
author | Ananthapadmanabhan, Saikrishna Vo, Giau Nguyen, Tuan Dimitri, Hany Otton, James |
author_facet | Ananthapadmanabhan, Saikrishna Vo, Giau Nguyen, Tuan Dimitri, Hany Otton, James |
author_sort | Ananthapadmanabhan, Saikrishna |
collection | PubMed |
description | BACKGROUND: Cardiac magnetic resonance feature tracking (CMR-FT) and speckle tracking echocardiography (STE) are well-established strain imaging modalities. Multilayer strain measurement permits independent assessment of endocardial and epicardial strain. This novel and layer specific approach to evaluating myocardial deformation parameters may provide greater insight into cardiac contractility when compared to whole-layer strain analysis. The aim of this study is to validate CMR-FT as a tool for multilayer strain analysis by providing a direct comparison between multilayer global longitudinal strain (GLS) values between CMR-FT and STE. METHODS: We studied 100 patients who had an acute myocardial infarction (AMI), who underwent CMR imaging and echocardiogram at baseline and follow-up (48 ± 13 days). Dedicated tissue tracking software was used to analyse single- and multi-layer GLS values for CMR-FT and STE. RESULTS: Correlation coefficients for CMR-FT and STE were 0.685, 0.687, and 0.660 for endocardial, epicardial, and whole-layer GLS respectively (all p < 0.001). Bland Altman analysis showed good inter-modality agreement with minimal bias. The absolute limits of agreement in our study were 6.4, 5.9, and 5.5 for endocardial, whole-layer, and epicardial GLS respectively. Absolute biases were 1.79, 0.80, and 0.98 respectively. Intraclass correlation coefficient (ICC) values showed moderate agreement with values of 0.626, 0.632, and 0.671 respectively (all p < 0.001). CONCLUSION: There is good inter-modality agreement between CMR-FT and STE for whole-layer, endocardial, and epicardial GLS, and although values should not be used interchangeably our study demonstrates that CMR-FT is a viable imaging modality for multilayer strain |
format | Online Article Text |
id | pubmed-7893897 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-78938972021-02-22 Direct comparison of multilayer left ventricular global longitudinal strain using CMR feature tracking and speckle tracking echocardiography Ananthapadmanabhan, Saikrishna Vo, Giau Nguyen, Tuan Dimitri, Hany Otton, James BMC Cardiovasc Disord Research Article BACKGROUND: Cardiac magnetic resonance feature tracking (CMR-FT) and speckle tracking echocardiography (STE) are well-established strain imaging modalities. Multilayer strain measurement permits independent assessment of endocardial and epicardial strain. This novel and layer specific approach to evaluating myocardial deformation parameters may provide greater insight into cardiac contractility when compared to whole-layer strain analysis. The aim of this study is to validate CMR-FT as a tool for multilayer strain analysis by providing a direct comparison between multilayer global longitudinal strain (GLS) values between CMR-FT and STE. METHODS: We studied 100 patients who had an acute myocardial infarction (AMI), who underwent CMR imaging and echocardiogram at baseline and follow-up (48 ± 13 days). Dedicated tissue tracking software was used to analyse single- and multi-layer GLS values for CMR-FT and STE. RESULTS: Correlation coefficients for CMR-FT and STE were 0.685, 0.687, and 0.660 for endocardial, epicardial, and whole-layer GLS respectively (all p < 0.001). Bland Altman analysis showed good inter-modality agreement with minimal bias. The absolute limits of agreement in our study were 6.4, 5.9, and 5.5 for endocardial, whole-layer, and epicardial GLS respectively. Absolute biases were 1.79, 0.80, and 0.98 respectively. Intraclass correlation coefficient (ICC) values showed moderate agreement with values of 0.626, 0.632, and 0.671 respectively (all p < 0.001). CONCLUSION: There is good inter-modality agreement between CMR-FT and STE for whole-layer, endocardial, and epicardial GLS, and although values should not be used interchangeably our study demonstrates that CMR-FT is a viable imaging modality for multilayer strain BioMed Central 2021-02-19 /pmc/articles/PMC7893897/ /pubmed/33607946 http://dx.doi.org/10.1186/s12872-021-01916-8 Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Ananthapadmanabhan, Saikrishna Vo, Giau Nguyen, Tuan Dimitri, Hany Otton, James Direct comparison of multilayer left ventricular global longitudinal strain using CMR feature tracking and speckle tracking echocardiography |
title | Direct comparison of multilayer left ventricular global longitudinal strain using CMR feature tracking and speckle tracking echocardiography |
title_full | Direct comparison of multilayer left ventricular global longitudinal strain using CMR feature tracking and speckle tracking echocardiography |
title_fullStr | Direct comparison of multilayer left ventricular global longitudinal strain using CMR feature tracking and speckle tracking echocardiography |
title_full_unstemmed | Direct comparison of multilayer left ventricular global longitudinal strain using CMR feature tracking and speckle tracking echocardiography |
title_short | Direct comparison of multilayer left ventricular global longitudinal strain using CMR feature tracking and speckle tracking echocardiography |
title_sort | direct comparison of multilayer left ventricular global longitudinal strain using cmr feature tracking and speckle tracking echocardiography |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7893897/ https://www.ncbi.nlm.nih.gov/pubmed/33607946 http://dx.doi.org/10.1186/s12872-021-01916-8 |
work_keys_str_mv | AT ananthapadmanabhansaikrishna directcomparisonofmultilayerleftventriculargloballongitudinalstrainusingcmrfeaturetrackingandspeckletrackingechocardiography AT vogiau directcomparisonofmultilayerleftventriculargloballongitudinalstrainusingcmrfeaturetrackingandspeckletrackingechocardiography AT nguyentuan directcomparisonofmultilayerleftventriculargloballongitudinalstrainusingcmrfeaturetrackingandspeckletrackingechocardiography AT dimitrihany directcomparisonofmultilayerleftventriculargloballongitudinalstrainusingcmrfeaturetrackingandspeckletrackingechocardiography AT ottonjames directcomparisonofmultilayerleftventriculargloballongitudinalstrainusingcmrfeaturetrackingandspeckletrackingechocardiography |