Cargando…

Direct comparison of multilayer left ventricular global longitudinal strain using CMR feature tracking and speckle tracking echocardiography

BACKGROUND: Cardiac magnetic resonance feature tracking (CMR-FT) and speckle tracking echocardiography (STE) are well-established strain imaging modalities. Multilayer strain measurement permits independent assessment of endocardial and epicardial strain. This novel and layer specific approach to ev...

Descripción completa

Detalles Bibliográficos
Autores principales: Ananthapadmanabhan, Saikrishna, Vo, Giau, Nguyen, Tuan, Dimitri, Hany, Otton, James
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7893897/
https://www.ncbi.nlm.nih.gov/pubmed/33607946
http://dx.doi.org/10.1186/s12872-021-01916-8
_version_ 1783653139833946112
author Ananthapadmanabhan, Saikrishna
Vo, Giau
Nguyen, Tuan
Dimitri, Hany
Otton, James
author_facet Ananthapadmanabhan, Saikrishna
Vo, Giau
Nguyen, Tuan
Dimitri, Hany
Otton, James
author_sort Ananthapadmanabhan, Saikrishna
collection PubMed
description BACKGROUND: Cardiac magnetic resonance feature tracking (CMR-FT) and speckle tracking echocardiography (STE) are well-established strain imaging modalities. Multilayer strain measurement permits independent assessment of endocardial and epicardial strain. This novel and layer specific approach to evaluating myocardial deformation parameters may provide greater insight into cardiac contractility when compared to whole-layer strain analysis. The aim of this study is to validate CMR-FT as a tool for multilayer strain analysis by providing a direct comparison between multilayer global longitudinal strain (GLS) values between CMR-FT and STE. METHODS: We studied 100 patients who had an acute myocardial infarction (AMI), who underwent CMR imaging and echocardiogram at baseline and follow-up (48 ± 13 days). Dedicated tissue tracking software was used to analyse single- and multi-layer GLS values for CMR-FT and STE. RESULTS: Correlation coefficients for CMR-FT and STE were 0.685, 0.687, and 0.660 for endocardial, epicardial, and whole-layer GLS respectively (all p < 0.001). Bland Altman analysis showed good inter-modality agreement with minimal bias. The absolute limits of agreement in our study were 6.4, 5.9, and 5.5 for endocardial, whole-layer, and epicardial GLS respectively. Absolute biases were 1.79, 0.80, and 0.98 respectively. Intraclass correlation coefficient (ICC) values showed moderate agreement with values of 0.626, 0.632, and 0.671 respectively (all p < 0.001). CONCLUSION: There is good inter-modality agreement between CMR-FT and STE for whole-layer, endocardial, and epicardial GLS, and although values should not be used interchangeably our study demonstrates that CMR-FT is a viable imaging modality for multilayer strain
format Online
Article
Text
id pubmed-7893897
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-78938972021-02-22 Direct comparison of multilayer left ventricular global longitudinal strain using CMR feature tracking and speckle tracking echocardiography Ananthapadmanabhan, Saikrishna Vo, Giau Nguyen, Tuan Dimitri, Hany Otton, James BMC Cardiovasc Disord Research Article BACKGROUND: Cardiac magnetic resonance feature tracking (CMR-FT) and speckle tracking echocardiography (STE) are well-established strain imaging modalities. Multilayer strain measurement permits independent assessment of endocardial and epicardial strain. This novel and layer specific approach to evaluating myocardial deformation parameters may provide greater insight into cardiac contractility when compared to whole-layer strain analysis. The aim of this study is to validate CMR-FT as a tool for multilayer strain analysis by providing a direct comparison between multilayer global longitudinal strain (GLS) values between CMR-FT and STE. METHODS: We studied 100 patients who had an acute myocardial infarction (AMI), who underwent CMR imaging and echocardiogram at baseline and follow-up (48 ± 13 days). Dedicated tissue tracking software was used to analyse single- and multi-layer GLS values for CMR-FT and STE. RESULTS: Correlation coefficients for CMR-FT and STE were 0.685, 0.687, and 0.660 for endocardial, epicardial, and whole-layer GLS respectively (all p < 0.001). Bland Altman analysis showed good inter-modality agreement with minimal bias. The absolute limits of agreement in our study were 6.4, 5.9, and 5.5 for endocardial, whole-layer, and epicardial GLS respectively. Absolute biases were 1.79, 0.80, and 0.98 respectively. Intraclass correlation coefficient (ICC) values showed moderate agreement with values of 0.626, 0.632, and 0.671 respectively (all p < 0.001). CONCLUSION: There is good inter-modality agreement between CMR-FT and STE for whole-layer, endocardial, and epicardial GLS, and although values should not be used interchangeably our study demonstrates that CMR-FT is a viable imaging modality for multilayer strain BioMed Central 2021-02-19 /pmc/articles/PMC7893897/ /pubmed/33607946 http://dx.doi.org/10.1186/s12872-021-01916-8 Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Ananthapadmanabhan, Saikrishna
Vo, Giau
Nguyen, Tuan
Dimitri, Hany
Otton, James
Direct comparison of multilayer left ventricular global longitudinal strain using CMR feature tracking and speckle tracking echocardiography
title Direct comparison of multilayer left ventricular global longitudinal strain using CMR feature tracking and speckle tracking echocardiography
title_full Direct comparison of multilayer left ventricular global longitudinal strain using CMR feature tracking and speckle tracking echocardiography
title_fullStr Direct comparison of multilayer left ventricular global longitudinal strain using CMR feature tracking and speckle tracking echocardiography
title_full_unstemmed Direct comparison of multilayer left ventricular global longitudinal strain using CMR feature tracking and speckle tracking echocardiography
title_short Direct comparison of multilayer left ventricular global longitudinal strain using CMR feature tracking and speckle tracking echocardiography
title_sort direct comparison of multilayer left ventricular global longitudinal strain using cmr feature tracking and speckle tracking echocardiography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7893897/
https://www.ncbi.nlm.nih.gov/pubmed/33607946
http://dx.doi.org/10.1186/s12872-021-01916-8
work_keys_str_mv AT ananthapadmanabhansaikrishna directcomparisonofmultilayerleftventriculargloballongitudinalstrainusingcmrfeaturetrackingandspeckletrackingechocardiography
AT vogiau directcomparisonofmultilayerleftventriculargloballongitudinalstrainusingcmrfeaturetrackingandspeckletrackingechocardiography
AT nguyentuan directcomparisonofmultilayerleftventriculargloballongitudinalstrainusingcmrfeaturetrackingandspeckletrackingechocardiography
AT dimitrihany directcomparisonofmultilayerleftventriculargloballongitudinalstrainusingcmrfeaturetrackingandspeckletrackingechocardiography
AT ottonjames directcomparisonofmultilayerleftventriculargloballongitudinalstrainusingcmrfeaturetrackingandspeckletrackingechocardiography