Evaluation of Polyethylene Wear in a Brazilian Ultracongruent Knee Prosthesis with a Rotating Platform
Objective To evaluate the wear of polyethylene in a Brazilian ultracongruent knee prosthesis with a rotating platform (Rotaflex, Víncula, Rio Claro, SP, Brasil). Methods We used the test method with the loading and preparation parameters mentioned in the standards regulation ISO 14243-1:2009 , and...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Thieme Revinter Publicações Ltda.
2021
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7895618/ https://www.ncbi.nlm.nih.gov/pubmed/33627898 http://dx.doi.org/10.1055/s-0040-1712491 |
_version_ | 1783653393106993152 |
---|---|
author | Pécora, José Ricardo Romero, Valéria |
author_facet | Pécora, José Ricardo Romero, Valéria |
author_sort | Pécora, José Ricardo |
collection | PubMed |
description | Objective To evaluate the wear of polyethylene in a Brazilian ultracongruent knee prosthesis with a rotating platform (Rotaflex, Víncula, Rio Claro, SP, Brasil). Methods We used the test method with the loading and preparation parameters mentioned in the standards regulation ISO 14243-1:2009 , and the measurement methods mentioned in the standards regulation ISO 14243-2:2009 , for the evaluation of the wear behavior of a Brazilian prosthesis with a rotating platform. The equipment used for the wear test was the ISO 14243–1 gait simulator (EndoLab, Riedering, Germany). Results After 10 million cycles, the evaluation of the polyethylene wear showed a regular appearance of surface wear at a mean rate of 2.56 mg per million cycles. Conclusion The wear of the polyethylene of the evaluated prosthesis was minimal after the tests performed and with safety limits higher than those recommended by biomechanical engineering. |
format | Online Article Text |
id | pubmed-7895618 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Thieme Revinter Publicações Ltda. |
record_format | MEDLINE/PubMed |
spelling | pubmed-78956182021-02-23 Evaluation of Polyethylene Wear in a Brazilian Ultracongruent Knee Prosthesis with a Rotating Platform Pécora, José Ricardo Romero, Valéria Rev Bras Ortop (Sao Paulo) Objective To evaluate the wear of polyethylene in a Brazilian ultracongruent knee prosthesis with a rotating platform (Rotaflex, Víncula, Rio Claro, SP, Brasil). Methods We used the test method with the loading and preparation parameters mentioned in the standards regulation ISO 14243-1:2009 , and the measurement methods mentioned in the standards regulation ISO 14243-2:2009 , for the evaluation of the wear behavior of a Brazilian prosthesis with a rotating platform. The equipment used for the wear test was the ISO 14243–1 gait simulator (EndoLab, Riedering, Germany). Results After 10 million cycles, the evaluation of the polyethylene wear showed a regular appearance of surface wear at a mean rate of 2.56 mg per million cycles. Conclusion The wear of the polyethylene of the evaluated prosthesis was minimal after the tests performed and with safety limits higher than those recommended by biomechanical engineering. Thieme Revinter Publicações Ltda. 2021-02 2020-06-10 /pmc/articles/PMC7895618/ /pubmed/33627898 http://dx.doi.org/10.1055/s-0040-1712491 Text en Sociedade Brasileira de Ortopedia e Traumatologia. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. ( https://creativecommons.org/licenses/by-nc-nd/4.0/ ) https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited. |
spellingShingle | Pécora, José Ricardo Romero, Valéria Evaluation of Polyethylene Wear in a Brazilian Ultracongruent Knee Prosthesis with a Rotating Platform |
title |
Evaluation of Polyethylene Wear in a Brazilian Ultracongruent Knee Prosthesis with a Rotating Platform
|
title_full |
Evaluation of Polyethylene Wear in a Brazilian Ultracongruent Knee Prosthesis with a Rotating Platform
|
title_fullStr |
Evaluation of Polyethylene Wear in a Brazilian Ultracongruent Knee Prosthesis with a Rotating Platform
|
title_full_unstemmed |
Evaluation of Polyethylene Wear in a Brazilian Ultracongruent Knee Prosthesis with a Rotating Platform
|
title_short |
Evaluation of Polyethylene Wear in a Brazilian Ultracongruent Knee Prosthesis with a Rotating Platform
|
title_sort | evaluation of polyethylene wear in a brazilian ultracongruent knee prosthesis with a rotating platform |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7895618/ https://www.ncbi.nlm.nih.gov/pubmed/33627898 http://dx.doi.org/10.1055/s-0040-1712491 |
work_keys_str_mv | AT pecorajosericardo evaluationofpolyethylenewearinabrazilianultracongruentkneeprosthesiswitharotatingplatform AT romerovaleria evaluationofpolyethylenewearinabrazilianultracongruentkneeprosthesiswitharotatingplatform |