Cargando…

Keratoconus Features on Corneal Higher-Order Aberration Ablation Maps: Proof-of-Concept of a New Diagnostic Modality

PURPOSE: To assess the potential application of corneal higher-order aberration (HOA) excimer ablation map imaging in identifying reproducible keratoconus (KC) features and to explore if newly derived map metrics correlate to Pentacam KC indices. METHODS: Case series of 12 eyes with KC ≥ grade 2. To...

Descripción completa

Detalles Bibliográficos
Autores principales: Wallerstein, Avi, Gauvin, Mathieu, Mimouni, Michael, Racine, Louis, Salimi, Ali, Cohen, Mark
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7896763/
https://www.ncbi.nlm.nih.gov/pubmed/33623363
http://dx.doi.org/10.2147/OPTH.S296724
_version_ 1783653605607211008
author Wallerstein, Avi
Gauvin, Mathieu
Mimouni, Michael
Racine, Louis
Salimi, Ali
Cohen, Mark
author_facet Wallerstein, Avi
Gauvin, Mathieu
Mimouni, Michael
Racine, Louis
Salimi, Ali
Cohen, Mark
author_sort Wallerstein, Avi
collection PubMed
description PURPOSE: To assess the potential application of corneal higher-order aberration (HOA) excimer ablation map imaging in identifying reproducible keratoconus (KC) features and to explore if newly derived map metrics correlate to Pentacam KC indices. METHODS: Case series of 12 eyes with KC ≥ grade 2. Topolyzer Vario corneal imaging with its resultant HOA ablation map islands were analyzed for their centroid, distance from center, angular position, orientation, sphericity, diameter, area, and maximal ablation depth. Correlations to Pentacam indices were studied. RESULTS: All eyes showed recurrent features with an arrangement of two elliptical paracentral ablation islands, one deep inferotemporal and one shallow superonasal, in direct mirror-like opposition to each other. These were always accompanied by superior peripheral ablation crescents. The two paracentral islands had highly reproducible distance from center (1.2 ± 0.1 mm and 1.3 ± 0. 2 mm) and angular positions (246.8 ± 15.9° and 76.7 ± 7.7°), with greater variation in ablation depth (68.3 ± 33.2 µm and 17.6 ± 12.1 µm). Distance from center of the peripheral superior crescents was highly reproducible (3.3 ± 0.1 mm), with a larger range of depth (74.5 ± 37.2 µm). The deep paracentral inferotemporal island “hot spot” was coincident with the topographical apical cone. Strong correlations were found between the depth of the inferotemporal island and Pentacam indices of posterior radius curvature (PRC: R = −0.74) and Belin/Ambrosio enhanced ectasia total deviation (BAD-D: R = 0.71). CONCLUSION: The corneal HOA ablation map revealed a recurring, distinct, easily recognizable pattern in KC eyes. There was a strong correlation between the depth of novel HOA ablation map metrics and validated Pentacam KC indices. Novel information can be extracted from the corneal HOA ablation map giving it the potential to be a new modality to diagnose and grade KC.
format Online
Article
Text
id pubmed-7896763
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-78967632021-02-22 Keratoconus Features on Corneal Higher-Order Aberration Ablation Maps: Proof-of-Concept of a New Diagnostic Modality Wallerstein, Avi Gauvin, Mathieu Mimouni, Michael Racine, Louis Salimi, Ali Cohen, Mark Clin Ophthalmol Original Research PURPOSE: To assess the potential application of corneal higher-order aberration (HOA) excimer ablation map imaging in identifying reproducible keratoconus (KC) features and to explore if newly derived map metrics correlate to Pentacam KC indices. METHODS: Case series of 12 eyes with KC ≥ grade 2. Topolyzer Vario corneal imaging with its resultant HOA ablation map islands were analyzed for their centroid, distance from center, angular position, orientation, sphericity, diameter, area, and maximal ablation depth. Correlations to Pentacam indices were studied. RESULTS: All eyes showed recurrent features with an arrangement of two elliptical paracentral ablation islands, one deep inferotemporal and one shallow superonasal, in direct mirror-like opposition to each other. These were always accompanied by superior peripheral ablation crescents. The two paracentral islands had highly reproducible distance from center (1.2 ± 0.1 mm and 1.3 ± 0. 2 mm) and angular positions (246.8 ± 15.9° and 76.7 ± 7.7°), with greater variation in ablation depth (68.3 ± 33.2 µm and 17.6 ± 12.1 µm). Distance from center of the peripheral superior crescents was highly reproducible (3.3 ± 0.1 mm), with a larger range of depth (74.5 ± 37.2 µm). The deep paracentral inferotemporal island “hot spot” was coincident with the topographical apical cone. Strong correlations were found between the depth of the inferotemporal island and Pentacam indices of posterior radius curvature (PRC: R = −0.74) and Belin/Ambrosio enhanced ectasia total deviation (BAD-D: R = 0.71). CONCLUSION: The corneal HOA ablation map revealed a recurring, distinct, easily recognizable pattern in KC eyes. There was a strong correlation between the depth of novel HOA ablation map metrics and validated Pentacam KC indices. Novel information can be extracted from the corneal HOA ablation map giving it the potential to be a new modality to diagnose and grade KC. Dove 2021-02-16 /pmc/articles/PMC7896763/ /pubmed/33623363 http://dx.doi.org/10.2147/OPTH.S296724 Text en © 2021 Wallerstein et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Wallerstein, Avi
Gauvin, Mathieu
Mimouni, Michael
Racine, Louis
Salimi, Ali
Cohen, Mark
Keratoconus Features on Corneal Higher-Order Aberration Ablation Maps: Proof-of-Concept of a New Diagnostic Modality
title Keratoconus Features on Corneal Higher-Order Aberration Ablation Maps: Proof-of-Concept of a New Diagnostic Modality
title_full Keratoconus Features on Corneal Higher-Order Aberration Ablation Maps: Proof-of-Concept of a New Diagnostic Modality
title_fullStr Keratoconus Features on Corneal Higher-Order Aberration Ablation Maps: Proof-of-Concept of a New Diagnostic Modality
title_full_unstemmed Keratoconus Features on Corneal Higher-Order Aberration Ablation Maps: Proof-of-Concept of a New Diagnostic Modality
title_short Keratoconus Features on Corneal Higher-Order Aberration Ablation Maps: Proof-of-Concept of a New Diagnostic Modality
title_sort keratoconus features on corneal higher-order aberration ablation maps: proof-of-concept of a new diagnostic modality
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7896763/
https://www.ncbi.nlm.nih.gov/pubmed/33623363
http://dx.doi.org/10.2147/OPTH.S296724
work_keys_str_mv AT wallersteinavi keratoconusfeaturesoncornealhigherorderaberrationablationmapsproofofconceptofanewdiagnosticmodality
AT gauvinmathieu keratoconusfeaturesoncornealhigherorderaberrationablationmapsproofofconceptofanewdiagnosticmodality
AT mimounimichael keratoconusfeaturesoncornealhigherorderaberrationablationmapsproofofconceptofanewdiagnosticmodality
AT racinelouis keratoconusfeaturesoncornealhigherorderaberrationablationmapsproofofconceptofanewdiagnosticmodality
AT salimiali keratoconusfeaturesoncornealhigherorderaberrationablationmapsproofofconceptofanewdiagnosticmodality
AT cohenmark keratoconusfeaturesoncornealhigherorderaberrationablationmapsproofofconceptofanewdiagnosticmodality