Cargando…
Development and Validation of a Simple, Green Infrared Spectroscopic Method for Quantitation of Sildenafil Citrate in Siloflam Tablets of Unknown Manufacturing Formula
A simple, easy-to-implement, and green infrared spectroscopic method was developed and validated for the quantitative determination of sildenafil citrate in tablets of unknown manufacturing formula. Homogenized tablet powder with known mass content (%, m/m) of sildenafil citrate was mixed with parac...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7896866/ https://www.ncbi.nlm.nih.gov/pubmed/33628575 http://dx.doi.org/10.1155/2021/6616728 |
_version_ | 1783653628776546304 |
---|---|
author | Bui, Van Trung Doan, Cao Son Tong, Thi Thanh Vuong Le, Dinh Chi |
author_facet | Bui, Van Trung Doan, Cao Son Tong, Thi Thanh Vuong Le, Dinh Chi |
author_sort | Bui, Van Trung |
collection | PubMed |
description | A simple, easy-to-implement, and green infrared spectroscopic method was developed and validated for the quantitative determination of sildenafil citrate in tablets of unknown manufacturing formula. Homogenized tablet powder with known mass content (%, m/m) of sildenafil citrate was mixed with paracetamol to form standard mixtures with different percentages of sildenafil citrate on the total quantity of sildenafil citrate and paracetamol (designated as R). Unknown tablet samples were finely ground and mixed with paracetamol to form test mixtures having R values about 50%. Infrared spectra of standard mixtures, measured in attenuated total reflectance mode, in the wavenumber zone from 1800 cm(−1) to 1300 cm(−1) were selected and processed by partial least square regression to form the calibration model for quantitation of sildenafil citrate in unknown samples. Spectral responses of test mixtures and the calibration model were used to determine the exact mass content (%, m/m) of sildenafil citrate in the powder of unknown tablet samples. The method was fully validated in terms of linearity, precision, and accuracy according to the requirements of current guidelines and was proved as reliable and suitable for the intended application. |
format | Online Article Text |
id | pubmed-7896866 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-78968662021-02-23 Development and Validation of a Simple, Green Infrared Spectroscopic Method for Quantitation of Sildenafil Citrate in Siloflam Tablets of Unknown Manufacturing Formula Bui, Van Trung Doan, Cao Son Tong, Thi Thanh Vuong Le, Dinh Chi J Anal Methods Chem Research Article A simple, easy-to-implement, and green infrared spectroscopic method was developed and validated for the quantitative determination of sildenafil citrate in tablets of unknown manufacturing formula. Homogenized tablet powder with known mass content (%, m/m) of sildenafil citrate was mixed with paracetamol to form standard mixtures with different percentages of sildenafil citrate on the total quantity of sildenafil citrate and paracetamol (designated as R). Unknown tablet samples were finely ground and mixed with paracetamol to form test mixtures having R values about 50%. Infrared spectra of standard mixtures, measured in attenuated total reflectance mode, in the wavenumber zone from 1800 cm(−1) to 1300 cm(−1) were selected and processed by partial least square regression to form the calibration model for quantitation of sildenafil citrate in unknown samples. Spectral responses of test mixtures and the calibration model were used to determine the exact mass content (%, m/m) of sildenafil citrate in the powder of unknown tablet samples. The method was fully validated in terms of linearity, precision, and accuracy according to the requirements of current guidelines and was proved as reliable and suitable for the intended application. Hindawi 2021-02-13 /pmc/articles/PMC7896866/ /pubmed/33628575 http://dx.doi.org/10.1155/2021/6616728 Text en Copyright © 2021 Van Trung Bui et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Bui, Van Trung Doan, Cao Son Tong, Thi Thanh Vuong Le, Dinh Chi Development and Validation of a Simple, Green Infrared Spectroscopic Method for Quantitation of Sildenafil Citrate in Siloflam Tablets of Unknown Manufacturing Formula |
title | Development and Validation of a Simple, Green Infrared Spectroscopic Method for Quantitation of Sildenafil Citrate in Siloflam Tablets of Unknown Manufacturing Formula |
title_full | Development and Validation of a Simple, Green Infrared Spectroscopic Method for Quantitation of Sildenafil Citrate in Siloflam Tablets of Unknown Manufacturing Formula |
title_fullStr | Development and Validation of a Simple, Green Infrared Spectroscopic Method for Quantitation of Sildenafil Citrate in Siloflam Tablets of Unknown Manufacturing Formula |
title_full_unstemmed | Development and Validation of a Simple, Green Infrared Spectroscopic Method for Quantitation of Sildenafil Citrate in Siloflam Tablets of Unknown Manufacturing Formula |
title_short | Development and Validation of a Simple, Green Infrared Spectroscopic Method for Quantitation of Sildenafil Citrate in Siloflam Tablets of Unknown Manufacturing Formula |
title_sort | development and validation of a simple, green infrared spectroscopic method for quantitation of sildenafil citrate in siloflam tablets of unknown manufacturing formula |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7896866/ https://www.ncbi.nlm.nih.gov/pubmed/33628575 http://dx.doi.org/10.1155/2021/6616728 |
work_keys_str_mv | AT buivantrung developmentandvalidationofasimplegreeninfraredspectroscopicmethodforquantitationofsildenafilcitrateinsiloflamtabletsofunknownmanufacturingformula AT doancaoson developmentandvalidationofasimplegreeninfraredspectroscopicmethodforquantitationofsildenafilcitrateinsiloflamtabletsofunknownmanufacturingformula AT tongthithanhvuong developmentandvalidationofasimplegreeninfraredspectroscopicmethodforquantitationofsildenafilcitrateinsiloflamtabletsofunknownmanufacturingformula AT ledinhchi developmentandvalidationofasimplegreeninfraredspectroscopicmethodforquantitationofsildenafilcitrateinsiloflamtabletsofunknownmanufacturingformula |