Concordance between Body Composition Indices Measured with Dual-Energy X-Ray Absorptiometry and Bioelectrical Impedance Analysis in Obese Children in Sri Lanka

Dual-energy X-ray absorptiometry (DXA) is the reference standard in the measurement of body composition indices. But, its utility is limited due to the high cost, expertise required, lack of portability, and restricted availability. Therefore, bioelectrical impedance analysis (BIA) has gained recogn...

Descripción completa

Detalles Bibliográficos
Autores principales: de Silva, Mawanane Hewa Aruna Devapriya, Hewawasam, Ruwani Punyakanthi, Lekamwasam, Sarath
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7896873/
https://www.ncbi.nlm.nih.gov/pubmed/33628278
http://dx.doi.org/10.1155/2021/6638057
_version_ 1783653630378770432
author de Silva, Mawanane Hewa Aruna Devapriya
Hewawasam, Ruwani Punyakanthi
Lekamwasam, Sarath
author_facet de Silva, Mawanane Hewa Aruna Devapriya
Hewawasam, Ruwani Punyakanthi
Lekamwasam, Sarath
author_sort de Silva, Mawanane Hewa Aruna Devapriya
collection PubMed
description Dual-energy X-ray absorptiometry (DXA) is the reference standard in the measurement of body composition indices. But, its utility is limited due to the high cost, expertise required, lack of portability, and restricted availability. Therefore, bioelectrical impedance analysis (BIA) has gained recognition in resource-limited settings for the measurement of body composition indices in the screening of children for childhood obesity. To determine whether BIA represents a viable alternative to DXA in the assessment of body composition in obese children in the community setting in Sri Lanka, the concordance between BIA and DXA was determined. Fat mass (FM), percentage fat mass (%FM), and fat-free mass (FFM) were measured in 97 obese children using DXA and BIA, and the concordance between the methods was analyzed using independent sample t-test, regression analysis, and Bland-Altman plots. Significant mean differences were observed between DXA and BIA in measuring FM and FFM. However, high correlations were seen in DXA- and BMI-derived FM and FFM measurements (FM r = 0.92 and FFM 0.83, P < 0.001 for both). Compared to DXA, BIA overestimated FM and %FM and underestimated FFM. When compared with DXA-derived measurements, the accuracy errors (SEE) of BIA for FM, FFM, and %FM were relatively higher in boys (3.56 kg, 4.49 kg, and 5.46%, respectively) than in girls (2.44 kg, 3.72 kg, and 3.5%), respectively. BA plots showed a systematic error in the measurements of FM, FFM, and %FM in both sexes. Despite the limitations inherited, BIA is a viable alternative to DXA for the measurement of body composition in obese children of 5-15 yrs. The accuracy errors observed, however, need to be taken into consideration when interpreting results at the individual level.
format Online
Article
Text
id pubmed-7896873
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-78968732021-02-23 Concordance between Body Composition Indices Measured with Dual-Energy X-Ray Absorptiometry and Bioelectrical Impedance Analysis in Obese Children in Sri Lanka de Silva, Mawanane Hewa Aruna Devapriya Hewawasam, Ruwani Punyakanthi Lekamwasam, Sarath Int J Pediatr Research Article Dual-energy X-ray absorptiometry (DXA) is the reference standard in the measurement of body composition indices. But, its utility is limited due to the high cost, expertise required, lack of portability, and restricted availability. Therefore, bioelectrical impedance analysis (BIA) has gained recognition in resource-limited settings for the measurement of body composition indices in the screening of children for childhood obesity. To determine whether BIA represents a viable alternative to DXA in the assessment of body composition in obese children in the community setting in Sri Lanka, the concordance between BIA and DXA was determined. Fat mass (FM), percentage fat mass (%FM), and fat-free mass (FFM) were measured in 97 obese children using DXA and BIA, and the concordance between the methods was analyzed using independent sample t-test, regression analysis, and Bland-Altman plots. Significant mean differences were observed between DXA and BIA in measuring FM and FFM. However, high correlations were seen in DXA- and BMI-derived FM and FFM measurements (FM r = 0.92 and FFM 0.83, P < 0.001 for both). Compared to DXA, BIA overestimated FM and %FM and underestimated FFM. When compared with DXA-derived measurements, the accuracy errors (SEE) of BIA for FM, FFM, and %FM were relatively higher in boys (3.56 kg, 4.49 kg, and 5.46%, respectively) than in girls (2.44 kg, 3.72 kg, and 3.5%), respectively. BA plots showed a systematic error in the measurements of FM, FFM, and %FM in both sexes. Despite the limitations inherited, BIA is a viable alternative to DXA for the measurement of body composition in obese children of 5-15 yrs. The accuracy errors observed, however, need to be taken into consideration when interpreting results at the individual level. Hindawi 2021-02-12 /pmc/articles/PMC7896873/ /pubmed/33628278 http://dx.doi.org/10.1155/2021/6638057 Text en Copyright © 2021 Mawanane Hewa Aruna Devapriya de Silva et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
de Silva, Mawanane Hewa Aruna Devapriya
Hewawasam, Ruwani Punyakanthi
Lekamwasam, Sarath
Concordance between Body Composition Indices Measured with Dual-Energy X-Ray Absorptiometry and Bioelectrical Impedance Analysis in Obese Children in Sri Lanka
title Concordance between Body Composition Indices Measured with Dual-Energy X-Ray Absorptiometry and Bioelectrical Impedance Analysis in Obese Children in Sri Lanka
title_full Concordance between Body Composition Indices Measured with Dual-Energy X-Ray Absorptiometry and Bioelectrical Impedance Analysis in Obese Children in Sri Lanka
title_fullStr Concordance between Body Composition Indices Measured with Dual-Energy X-Ray Absorptiometry and Bioelectrical Impedance Analysis in Obese Children in Sri Lanka
title_full_unstemmed Concordance between Body Composition Indices Measured with Dual-Energy X-Ray Absorptiometry and Bioelectrical Impedance Analysis in Obese Children in Sri Lanka
title_short Concordance between Body Composition Indices Measured with Dual-Energy X-Ray Absorptiometry and Bioelectrical Impedance Analysis in Obese Children in Sri Lanka
title_sort concordance between body composition indices measured with dual-energy x-ray absorptiometry and bioelectrical impedance analysis in obese children in sri lanka
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7896873/
https://www.ncbi.nlm.nih.gov/pubmed/33628278
http://dx.doi.org/10.1155/2021/6638057
work_keys_str_mv AT desilvamawananehewaarunadevapriya concordancebetweenbodycompositionindicesmeasuredwithdualenergyxrayabsorptiometryandbioelectricalimpedanceanalysisinobesechildreninsrilanka
AT hewawasamruwanipunyakanthi concordancebetweenbodycompositionindicesmeasuredwithdualenergyxrayabsorptiometryandbioelectricalimpedanceanalysisinobesechildreninsrilanka
AT lekamwasamsarath concordancebetweenbodycompositionindicesmeasuredwithdualenergyxrayabsorptiometryandbioelectricalimpedanceanalysisinobesechildreninsrilanka