Cargando…

Evaluator effect on the ultrasound measurement of subcutaneous fat deposition and loin eye area from weaning to slaughter lambs

BACKGROUND AND AIM: Ultrasound is a non-invasive technique that enables animal evaluation and body condition classification of animals. Although it is not difficult to obtain an image, the analysis of this image can influence results quality. This study aimed to evaluate the repeatability and reprod...

Descripción completa

Detalles Bibliográficos
Autores principales: Junior, Fernando Miranda de Vargas, Fernandes, Tatiane, de Matos, Alexsander Toniazzo, Fernandes, Alexandre Rodrigo Mendes, Alves, Luis Gustavo Castro, Rossatti, Julianna Andrade, Britez, Gustavo Daniel Vega, Zagonel, Natássia Gabriela Targanski
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Veterinary World 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7896898/
https://www.ncbi.nlm.nih.gov/pubmed/33642812
http://dx.doi.org/10.14202/vetworld.2021.259-264
Descripción
Sumario:BACKGROUND AND AIM: Ultrasound is a non-invasive technique that enables animal evaluation and body condition classification of animals. Although it is not difficult to obtain an image, the analysis of this image can influence results quality. This study aimed to evaluate the repeatability and reproducibility of the technician trained in image interpretation obtained using different ultrasound frequencies. MATERIALS AND METHODS: Ninety-six lambs were used, ranging in weight from 15 to 40 kg. The images were captured using a linear probe of 13 cm, with a 3.5 megahertz (MHz) frequency and an acoustic couplant aid “standoff” or using a multifrequency transducer (6 and 8 MHz), on B mode, with a linear probe and 8.0 MHz frequency. All measurements were performed by the same technician, on the left side, between the 12(th) and 13(th) rib. Five different evaluators, at two different times, with aid of Image J software measured the loin eye area (LEA; only for images obtained with 3.5 MHz), Longissimus thoracis et lumborum depth (DLM), subcutaneous fat thickness (SFT), subcutaneous fat thickness plus skin (SFST), and skin thickness (ST). RESULTS: For LEA, DLM, SFT, SFST, and ST, variation was observed (p<0.01) between evaluators; however, there was no difference (p>0.05) between the 2 times of evaluation. Images measurements obtained with a frequency of 8.0 MHz had better repeatability indices and reproducibility indices. Accordingly, the identity test demonstrated that measurements performed on images obtained using 3.5 or 8.0 MHz were not equivalent. CONCLUSION: Ultrasound image measurements obtained using an 8.0 MHz frequency were more accurate and precise. It is important to use only one evaluator or providing the simultaneous training for all evaluators.