Cargando…
Baseline High Sensitivity Cardiac Troponin I Level Below Limit of Quantitation Rules Out Acute Myocardial Infarction in the Emergency Department
The objective of our study was to determine the utility of a baseline high sensitivity cardiac troponin (hs-cTnI) value below the limit of quantitation to rule-out acute myocardial infarction (AMI) in patients presenting to the emergency department (ED) with any suspicious symptoms of a cardiac etio...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7899745/ https://www.ncbi.nlm.nih.gov/pubmed/32639243 http://dx.doi.org/10.1097/HPC.0000000000000230 |
_version_ | 1783654071083728896 |
---|---|
author | Cook, Bernard McCord, James Hudson, Michael Al-Darzi, Waleed Moyer, Michele Jacobsen, Gordon Nowak, Richard |
author_facet | Cook, Bernard McCord, James Hudson, Michael Al-Darzi, Waleed Moyer, Michele Jacobsen, Gordon Nowak, Richard |
author_sort | Cook, Bernard |
collection | PubMed |
description | The objective of our study was to determine the utility of a baseline high sensitivity cardiac troponin (hs-cTnI) value below the limit of quantitation to rule-out acute myocardial infarction (AMI) in patients presenting to the emergency department (ED) with any suspicious symptoms of a cardiac etiology. We enrolled subjects presenting to the ED with symptoms suspicious for AMI. Blood specimens were collected within 1 hour after a triage electrocardiogram. Cardiac troponin I was measured using the Beckman Coulter Access hs-cTnI assay. The diagnosis of AMI was adjudicated by 2 cardiologists using the Third Universal Definition of AMI and Roche Diagnostics Troponin T Generation 5 assay with all available clinical data at 30 days after presentation. A total of 567 subjects had all data required for data analyses. AMI was diagnosed in 46 (8.1%) patients. Two hundred thirty-two (40.9%) individuals had presentation hs-cTnI results <4.0 ng/L. None of the patients with baseline hs-cTnI <4.0 ng/L had an AMI, yielding a negative predictive value of 100.0% and a sensitivity of 100%, and a good prognosis (no AMIs or cardiac-related deaths at 30 days). In this single-center ED study, a baseline presenting novel hs-cTnI value of <4.0 ng/L effectively ruled out AMI in 40.9% of all patients presenting to the ED and having any symptoms suspicious for AMI. Importantly all patients, not only those with chest pain, and those having symptoms for any duration or those with end-stage renal disease requiring dialysis were included. |
format | Online Article Text |
id | pubmed-7899745 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-78997452021-03-01 Baseline High Sensitivity Cardiac Troponin I Level Below Limit of Quantitation Rules Out Acute Myocardial Infarction in the Emergency Department Cook, Bernard McCord, James Hudson, Michael Al-Darzi, Waleed Moyer, Michele Jacobsen, Gordon Nowak, Richard Crit Pathw Cardiol Original Studies The objective of our study was to determine the utility of a baseline high sensitivity cardiac troponin (hs-cTnI) value below the limit of quantitation to rule-out acute myocardial infarction (AMI) in patients presenting to the emergency department (ED) with any suspicious symptoms of a cardiac etiology. We enrolled subjects presenting to the ED with symptoms suspicious for AMI. Blood specimens were collected within 1 hour after a triage electrocardiogram. Cardiac troponin I was measured using the Beckman Coulter Access hs-cTnI assay. The diagnosis of AMI was adjudicated by 2 cardiologists using the Third Universal Definition of AMI and Roche Diagnostics Troponin T Generation 5 assay with all available clinical data at 30 days after presentation. A total of 567 subjects had all data required for data analyses. AMI was diagnosed in 46 (8.1%) patients. Two hundred thirty-two (40.9%) individuals had presentation hs-cTnI results <4.0 ng/L. None of the patients with baseline hs-cTnI <4.0 ng/L had an AMI, yielding a negative predictive value of 100.0% and a sensitivity of 100%, and a good prognosis (no AMIs or cardiac-related deaths at 30 days). In this single-center ED study, a baseline presenting novel hs-cTnI value of <4.0 ng/L effectively ruled out AMI in 40.9% of all patients presenting to the ED and having any symptoms suspicious for AMI. Importantly all patients, not only those with chest pain, and those having symptoms for any duration or those with end-stage renal disease requiring dialysis were included. Lippincott Williams & Wilkins 2020-07-01 2021-03 /pmc/articles/PMC7899745/ /pubmed/32639243 http://dx.doi.org/10.1097/HPC.0000000000000230 Text en Copyright © 2020 The Author(s). Published by Wolters Kluwer Health, Inc. This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. |
spellingShingle | Original Studies Cook, Bernard McCord, James Hudson, Michael Al-Darzi, Waleed Moyer, Michele Jacobsen, Gordon Nowak, Richard Baseline High Sensitivity Cardiac Troponin I Level Below Limit of Quantitation Rules Out Acute Myocardial Infarction in the Emergency Department |
title | Baseline High Sensitivity Cardiac Troponin I Level Below Limit of Quantitation Rules Out Acute Myocardial Infarction in the Emergency Department |
title_full | Baseline High Sensitivity Cardiac Troponin I Level Below Limit of Quantitation Rules Out Acute Myocardial Infarction in the Emergency Department |
title_fullStr | Baseline High Sensitivity Cardiac Troponin I Level Below Limit of Quantitation Rules Out Acute Myocardial Infarction in the Emergency Department |
title_full_unstemmed | Baseline High Sensitivity Cardiac Troponin I Level Below Limit of Quantitation Rules Out Acute Myocardial Infarction in the Emergency Department |
title_short | Baseline High Sensitivity Cardiac Troponin I Level Below Limit of Quantitation Rules Out Acute Myocardial Infarction in the Emergency Department |
title_sort | baseline high sensitivity cardiac troponin i level below limit of quantitation rules out acute myocardial infarction in the emergency department |
topic | Original Studies |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7899745/ https://www.ncbi.nlm.nih.gov/pubmed/32639243 http://dx.doi.org/10.1097/HPC.0000000000000230 |
work_keys_str_mv | AT cookbernard baselinehighsensitivitycardiactroponinilevelbelowlimitofquantitationrulesoutacutemyocardialinfarctionintheemergencydepartment AT mccordjames baselinehighsensitivitycardiactroponinilevelbelowlimitofquantitationrulesoutacutemyocardialinfarctionintheemergencydepartment AT hudsonmichael baselinehighsensitivitycardiactroponinilevelbelowlimitofquantitationrulesoutacutemyocardialinfarctionintheemergencydepartment AT aldarziwaleed baselinehighsensitivitycardiactroponinilevelbelowlimitofquantitationrulesoutacutemyocardialinfarctionintheemergencydepartment AT moyermichele baselinehighsensitivitycardiactroponinilevelbelowlimitofquantitationrulesoutacutemyocardialinfarctionintheemergencydepartment AT jacobsengordon baselinehighsensitivitycardiactroponinilevelbelowlimitofquantitationrulesoutacutemyocardialinfarctionintheemergencydepartment AT nowakrichard baselinehighsensitivitycardiactroponinilevelbelowlimitofquantitationrulesoutacutemyocardialinfarctionintheemergencydepartment |