Cargando…

Multiparametric in vivo ultrasound shear wave viscoelastography on farm-raised fatty duck livers: human radiology imaging applied to food sciences

Nine mulard ducks that were being raised for foie gras (steatosis) production went through in vivo shear wave (SW) elastography imaging of their liver during the force-feeding period to investigate changes in liver tissue characteristics. A total of 4 imaging sessions at an interval of 3 to 4 d were...

Descripción completa

Detalles Bibliográficos
Autores principales: Bhatt, Manish, Yazdani, Ladan, Destrempes, François, Allard, Louise, Nguyen, Bich N., Tang, An, Cloutier, Guy
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7900601/
https://www.ncbi.nlm.nih.gov/pubmed/33607316
http://dx.doi.org/10.1016/j.psj.2020.12.065
_version_ 1783654242072920064
author Bhatt, Manish
Yazdani, Ladan
Destrempes, François
Allard, Louise
Nguyen, Bich N.
Tang, An
Cloutier, Guy
author_facet Bhatt, Manish
Yazdani, Ladan
Destrempes, François
Allard, Louise
Nguyen, Bich N.
Tang, An
Cloutier, Guy
author_sort Bhatt, Manish
collection PubMed
description Nine mulard ducks that were being raised for foie gras (steatosis) production went through in vivo shear wave (SW) elastography imaging of their liver during the force-feeding period to investigate changes in liver tissue characteristics. A total of 4 imaging sessions at an interval of 3 to 4 d were conducted at the farm on each animal. Three ducks were sacrificed at the second, third, and fourth imaging sessions for histopathology analysis of all animals at these time points. Six SW elastography parameters were evaluated: SW speed, SW attenuation, SW dispersion, Young's modulus, viscosity, and shear modulus. Shear waves of different frequencies propagate with different phase velocities. Thus, SW speed and other dependent parameters such as Young's modulus, viscosity, and shear modulus were computed at 2 frequencies: 75 and 202 Hz. Each parameter depicted a statistically significant trend along the force-feeding process (P-values between 0.001 and 0.0001). The fat fraction of the liver increased over the 12-day period of feeding. All parameters increased monotonically over time at 75 Hz, whereas modal relations were seen at 202 Hz. Shear wave dispersion measured between 75 and 202 Hz depicted a plateau from day 5. Based on this validation, proposed imaging methods are aimed to be used in the future on naturally fed ducks and geese.
format Online
Article
Text
id pubmed-7900601
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-79006012021-03-03 Multiparametric in vivo ultrasound shear wave viscoelastography on farm-raised fatty duck livers: human radiology imaging applied to food sciences Bhatt, Manish Yazdani, Ladan Destrempes, François Allard, Louise Nguyen, Bich N. Tang, An Cloutier, Guy Poult Sci MANAGEMENT AND PRODUCTION Nine mulard ducks that were being raised for foie gras (steatosis) production went through in vivo shear wave (SW) elastography imaging of their liver during the force-feeding period to investigate changes in liver tissue characteristics. A total of 4 imaging sessions at an interval of 3 to 4 d were conducted at the farm on each animal. Three ducks were sacrificed at the second, third, and fourth imaging sessions for histopathology analysis of all animals at these time points. Six SW elastography parameters were evaluated: SW speed, SW attenuation, SW dispersion, Young's modulus, viscosity, and shear modulus. Shear waves of different frequencies propagate with different phase velocities. Thus, SW speed and other dependent parameters such as Young's modulus, viscosity, and shear modulus were computed at 2 frequencies: 75 and 202 Hz. Each parameter depicted a statistically significant trend along the force-feeding process (P-values between 0.001 and 0.0001). The fat fraction of the liver increased over the 12-day period of feeding. All parameters increased monotonically over time at 75 Hz, whereas modal relations were seen at 202 Hz. Shear wave dispersion measured between 75 and 202 Hz depicted a plateau from day 5. Based on this validation, proposed imaging methods are aimed to be used in the future on naturally fed ducks and geese. Elsevier 2020-12-31 /pmc/articles/PMC7900601/ /pubmed/33607316 http://dx.doi.org/10.1016/j.psj.2020.12.065 Text en © 2020 Published by Elsevier Inc. on behalf of Poultry Science Association Inc. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle MANAGEMENT AND PRODUCTION
Bhatt, Manish
Yazdani, Ladan
Destrempes, François
Allard, Louise
Nguyen, Bich N.
Tang, An
Cloutier, Guy
Multiparametric in vivo ultrasound shear wave viscoelastography on farm-raised fatty duck livers: human radiology imaging applied to food sciences
title Multiparametric in vivo ultrasound shear wave viscoelastography on farm-raised fatty duck livers: human radiology imaging applied to food sciences
title_full Multiparametric in vivo ultrasound shear wave viscoelastography on farm-raised fatty duck livers: human radiology imaging applied to food sciences
title_fullStr Multiparametric in vivo ultrasound shear wave viscoelastography on farm-raised fatty duck livers: human radiology imaging applied to food sciences
title_full_unstemmed Multiparametric in vivo ultrasound shear wave viscoelastography on farm-raised fatty duck livers: human radiology imaging applied to food sciences
title_short Multiparametric in vivo ultrasound shear wave viscoelastography on farm-raised fatty duck livers: human radiology imaging applied to food sciences
title_sort multiparametric in vivo ultrasound shear wave viscoelastography on farm-raised fatty duck livers: human radiology imaging applied to food sciences
topic MANAGEMENT AND PRODUCTION
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7900601/
https://www.ncbi.nlm.nih.gov/pubmed/33607316
http://dx.doi.org/10.1016/j.psj.2020.12.065
work_keys_str_mv AT bhattmanish multiparametricinvivoultrasoundshearwaveviscoelastographyonfarmraisedfattyducklivershumanradiologyimagingappliedtofoodsciences
AT yazdaniladan multiparametricinvivoultrasoundshearwaveviscoelastographyonfarmraisedfattyducklivershumanradiologyimagingappliedtofoodsciences
AT destrempesfrancois multiparametricinvivoultrasoundshearwaveviscoelastographyonfarmraisedfattyducklivershumanradiologyimagingappliedtofoodsciences
AT allardlouise multiparametricinvivoultrasoundshearwaveviscoelastographyonfarmraisedfattyducklivershumanradiologyimagingappliedtofoodsciences
AT nguyenbichn multiparametricinvivoultrasoundshearwaveviscoelastographyonfarmraisedfattyducklivershumanradiologyimagingappliedtofoodsciences
AT tangan multiparametricinvivoultrasoundshearwaveviscoelastographyonfarmraisedfattyducklivershumanradiologyimagingappliedtofoodsciences
AT cloutierguy multiparametricinvivoultrasoundshearwaveviscoelastographyonfarmraisedfattyducklivershumanradiologyimagingappliedtofoodsciences