Cargando…
Multiparametric in vivo ultrasound shear wave viscoelastography on farm-raised fatty duck livers: human radiology imaging applied to food sciences
Nine mulard ducks that were being raised for foie gras (steatosis) production went through in vivo shear wave (SW) elastography imaging of their liver during the force-feeding period to investigate changes in liver tissue characteristics. A total of 4 imaging sessions at an interval of 3 to 4 d were...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7900601/ https://www.ncbi.nlm.nih.gov/pubmed/33607316 http://dx.doi.org/10.1016/j.psj.2020.12.065 |
_version_ | 1783654242072920064 |
---|---|
author | Bhatt, Manish Yazdani, Ladan Destrempes, François Allard, Louise Nguyen, Bich N. Tang, An Cloutier, Guy |
author_facet | Bhatt, Manish Yazdani, Ladan Destrempes, François Allard, Louise Nguyen, Bich N. Tang, An Cloutier, Guy |
author_sort | Bhatt, Manish |
collection | PubMed |
description | Nine mulard ducks that were being raised for foie gras (steatosis) production went through in vivo shear wave (SW) elastography imaging of their liver during the force-feeding period to investigate changes in liver tissue characteristics. A total of 4 imaging sessions at an interval of 3 to 4 d were conducted at the farm on each animal. Three ducks were sacrificed at the second, third, and fourth imaging sessions for histopathology analysis of all animals at these time points. Six SW elastography parameters were evaluated: SW speed, SW attenuation, SW dispersion, Young's modulus, viscosity, and shear modulus. Shear waves of different frequencies propagate with different phase velocities. Thus, SW speed and other dependent parameters such as Young's modulus, viscosity, and shear modulus were computed at 2 frequencies: 75 and 202 Hz. Each parameter depicted a statistically significant trend along the force-feeding process (P-values between 0.001 and 0.0001). The fat fraction of the liver increased over the 12-day period of feeding. All parameters increased monotonically over time at 75 Hz, whereas modal relations were seen at 202 Hz. Shear wave dispersion measured between 75 and 202 Hz depicted a plateau from day 5. Based on this validation, proposed imaging methods are aimed to be used in the future on naturally fed ducks and geese. |
format | Online Article Text |
id | pubmed-7900601 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-79006012021-03-03 Multiparametric in vivo ultrasound shear wave viscoelastography on farm-raised fatty duck livers: human radiology imaging applied to food sciences Bhatt, Manish Yazdani, Ladan Destrempes, François Allard, Louise Nguyen, Bich N. Tang, An Cloutier, Guy Poult Sci MANAGEMENT AND PRODUCTION Nine mulard ducks that were being raised for foie gras (steatosis) production went through in vivo shear wave (SW) elastography imaging of their liver during the force-feeding period to investigate changes in liver tissue characteristics. A total of 4 imaging sessions at an interval of 3 to 4 d were conducted at the farm on each animal. Three ducks were sacrificed at the second, third, and fourth imaging sessions for histopathology analysis of all animals at these time points. Six SW elastography parameters were evaluated: SW speed, SW attenuation, SW dispersion, Young's modulus, viscosity, and shear modulus. Shear waves of different frequencies propagate with different phase velocities. Thus, SW speed and other dependent parameters such as Young's modulus, viscosity, and shear modulus were computed at 2 frequencies: 75 and 202 Hz. Each parameter depicted a statistically significant trend along the force-feeding process (P-values between 0.001 and 0.0001). The fat fraction of the liver increased over the 12-day period of feeding. All parameters increased monotonically over time at 75 Hz, whereas modal relations were seen at 202 Hz. Shear wave dispersion measured between 75 and 202 Hz depicted a plateau from day 5. Based on this validation, proposed imaging methods are aimed to be used in the future on naturally fed ducks and geese. Elsevier 2020-12-31 /pmc/articles/PMC7900601/ /pubmed/33607316 http://dx.doi.org/10.1016/j.psj.2020.12.065 Text en © 2020 Published by Elsevier Inc. on behalf of Poultry Science Association Inc. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | MANAGEMENT AND PRODUCTION Bhatt, Manish Yazdani, Ladan Destrempes, François Allard, Louise Nguyen, Bich N. Tang, An Cloutier, Guy Multiparametric in vivo ultrasound shear wave viscoelastography on farm-raised fatty duck livers: human radiology imaging applied to food sciences |
title | Multiparametric in vivo ultrasound shear wave viscoelastography on farm-raised fatty duck livers: human radiology imaging applied to food sciences |
title_full | Multiparametric in vivo ultrasound shear wave viscoelastography on farm-raised fatty duck livers: human radiology imaging applied to food sciences |
title_fullStr | Multiparametric in vivo ultrasound shear wave viscoelastography on farm-raised fatty duck livers: human radiology imaging applied to food sciences |
title_full_unstemmed | Multiparametric in vivo ultrasound shear wave viscoelastography on farm-raised fatty duck livers: human radiology imaging applied to food sciences |
title_short | Multiparametric in vivo ultrasound shear wave viscoelastography on farm-raised fatty duck livers: human radiology imaging applied to food sciences |
title_sort | multiparametric in vivo ultrasound shear wave viscoelastography on farm-raised fatty duck livers: human radiology imaging applied to food sciences |
topic | MANAGEMENT AND PRODUCTION |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7900601/ https://www.ncbi.nlm.nih.gov/pubmed/33607316 http://dx.doi.org/10.1016/j.psj.2020.12.065 |
work_keys_str_mv | AT bhattmanish multiparametricinvivoultrasoundshearwaveviscoelastographyonfarmraisedfattyducklivershumanradiologyimagingappliedtofoodsciences AT yazdaniladan multiparametricinvivoultrasoundshearwaveviscoelastographyonfarmraisedfattyducklivershumanradiologyimagingappliedtofoodsciences AT destrempesfrancois multiparametricinvivoultrasoundshearwaveviscoelastographyonfarmraisedfattyducklivershumanradiologyimagingappliedtofoodsciences AT allardlouise multiparametricinvivoultrasoundshearwaveviscoelastographyonfarmraisedfattyducklivershumanradiologyimagingappliedtofoodsciences AT nguyenbichn multiparametricinvivoultrasoundshearwaveviscoelastographyonfarmraisedfattyducklivershumanradiologyimagingappliedtofoodsciences AT tangan multiparametricinvivoultrasoundshearwaveviscoelastographyonfarmraisedfattyducklivershumanradiologyimagingappliedtofoodsciences AT cloutierguy multiparametricinvivoultrasoundshearwaveviscoelastographyonfarmraisedfattyducklivershumanradiologyimagingappliedtofoodsciences |