Atypical periprosthetic femur fracture on an underestimated atypical femoral pattern. A case report

CASE: Atypical fracture patterns, especially to the femur midshaft, have begun emerging since long-term bisphosphonate use was introduced. The same fracture pattern could arise around prosthetic hip implant, but the literature reports few cases regarding atypical periprosthetic femur fracture on pre...

Descripción completa

Detalles Bibliográficos
Autores principales: Caruso, Gaetano, Corradi, Nicola, Amoroso, Tommaso, Martini, Ilaria, Lorusso, Vincenzo, Massari, Leo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7900765/
https://www.ncbi.nlm.nih.gov/pubmed/33665304
http://dx.doi.org/10.1016/j.tcr.2021.100407
_version_ 1783654278594822144
author Caruso, Gaetano
Corradi, Nicola
Amoroso, Tommaso
Martini, Ilaria
Lorusso, Vincenzo
Massari, Leo
author_facet Caruso, Gaetano
Corradi, Nicola
Amoroso, Tommaso
Martini, Ilaria
Lorusso, Vincenzo
Massari, Leo
author_sort Caruso, Gaetano
collection PubMed
description CASE: Atypical fracture patterns, especially to the femur midshaft, have begun emerging since long-term bisphosphonate use was introduced. The same fracture pattern could arise around prosthetic hip implant, but the literature reports few cases regarding atypical periprosthetic femur fracture on previous total hip arthroplasty implant in patients on long-term bisphosphonate therapy. To our knowledge we report here the first case of atypical periprosthetic femur fracture arising after total hip arthroplasty implant on a previously identified but underestimated atypical femur pattern. CONCLUSION: Surgeons should never underestimate an atypical femur pattern on x-rays and always relate groin and thigh pain to hip pathology before performing total hip arthroplasty.
format Online
Article
Text
id pubmed-7900765
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-79007652021-03-03 Atypical periprosthetic femur fracture on an underestimated atypical femoral pattern. A case report Caruso, Gaetano Corradi, Nicola Amoroso, Tommaso Martini, Ilaria Lorusso, Vincenzo Massari, Leo Trauma Case Rep Case Report CASE: Atypical fracture patterns, especially to the femur midshaft, have begun emerging since long-term bisphosphonate use was introduced. The same fracture pattern could arise around prosthetic hip implant, but the literature reports few cases regarding atypical periprosthetic femur fracture on previous total hip arthroplasty implant in patients on long-term bisphosphonate therapy. To our knowledge we report here the first case of atypical periprosthetic femur fracture arising after total hip arthroplasty implant on a previously identified but underestimated atypical femur pattern. CONCLUSION: Surgeons should never underestimate an atypical femur pattern on x-rays and always relate groin and thigh pain to hip pathology before performing total hip arthroplasty. Elsevier 2021-02-10 /pmc/articles/PMC7900765/ /pubmed/33665304 http://dx.doi.org/10.1016/j.tcr.2021.100407 Text en © 2021 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Caruso, Gaetano
Corradi, Nicola
Amoroso, Tommaso
Martini, Ilaria
Lorusso, Vincenzo
Massari, Leo
Atypical periprosthetic femur fracture on an underestimated atypical femoral pattern. A case report
title Atypical periprosthetic femur fracture on an underestimated atypical femoral pattern. A case report
title_full Atypical periprosthetic femur fracture on an underestimated atypical femoral pattern. A case report
title_fullStr Atypical periprosthetic femur fracture on an underestimated atypical femoral pattern. A case report
title_full_unstemmed Atypical periprosthetic femur fracture on an underestimated atypical femoral pattern. A case report
title_short Atypical periprosthetic femur fracture on an underestimated atypical femoral pattern. A case report
title_sort atypical periprosthetic femur fracture on an underestimated atypical femoral pattern. a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7900765/
https://www.ncbi.nlm.nih.gov/pubmed/33665304
http://dx.doi.org/10.1016/j.tcr.2021.100407
work_keys_str_mv AT carusogaetano atypicalperiprostheticfemurfractureonanunderestimatedatypicalfemoralpatternacasereport
AT corradinicola atypicalperiprostheticfemurfractureonanunderestimatedatypicalfemoralpatternacasereport
AT amorosotommaso atypicalperiprostheticfemurfractureonanunderestimatedatypicalfemoralpatternacasereport
AT martiniilaria atypicalperiprostheticfemurfractureonanunderestimatedatypicalfemoralpatternacasereport
AT lorussovincenzo atypicalperiprostheticfemurfractureonanunderestimatedatypicalfemoralpatternacasereport
AT massarileo atypicalperiprostheticfemurfractureonanunderestimatedatypicalfemoralpatternacasereport