Cargando…

The Evaluation of APTT Reagents in Reference Plasma, Recombinant FVIII Products; Kovaltry® and Jivi® Using CWA, Including sTF/7FIX Assay

The FVIII activity in patients treated with several extended half-life FVIII (EHL-FVIII) agents different when various activated partial thromboplastin time (APTT) reagents were used. The present study examined the difference in clot waveform analysis (CWA) findings and FVIII activity when various A...

Descripción completa

Detalles Bibliográficos
Autores principales: Wada, Hideo, Shiraki, Katsuya, Matsumoto, Takeshi, Ohishi, Kohshi, Shimpo, Hideto, Sakano, Yumi, Nishii, Hiroko, Shimaoka, Motomu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7900842/
https://www.ncbi.nlm.nih.gov/pubmed/33606948
http://dx.doi.org/10.1177/1076029620976913
_version_ 1783654290812829696
author Wada, Hideo
Shiraki, Katsuya
Matsumoto, Takeshi
Ohishi, Kohshi
Shimpo, Hideto
Sakano, Yumi
Nishii, Hiroko
Shimaoka, Motomu
author_facet Wada, Hideo
Shiraki, Katsuya
Matsumoto, Takeshi
Ohishi, Kohshi
Shimpo, Hideto
Sakano, Yumi
Nishii, Hiroko
Shimaoka, Motomu
author_sort Wada, Hideo
collection PubMed
description The FVIII activity in patients treated with several extended half-life FVIII (EHL-FVIII) agents different when various activated partial thromboplastin time (APTT) reagents were used. The present study examined the difference in clot waveform analysis (CWA) findings and FVIII activity when various APTT reagents and CWA were used. The CWA including FVIII activity was measured using 12 APTT reagents, and the FIX activation based on a small amount of tissue factor assay (sTF/FIX) were examined in reference plasma (RP), EHL-FVIII (Jivi(®)) and Kovaltry(®). The 3 APTT reagents were associated with high variation in the peak time and height in the CWA when analyzing low concentrations of FVIII. The peak time and height could not be measured with one APTT reagent, and there were marked differences in the CWA findings between Jivi(®) and Kovaltry(®) among APTT reagents. Several APTT reagents showed a markedly lower FVIII activity with Jivi(®) than with Kovaltry(®). In the FVIII assay, the peak time measured with sTF/FIX did not differ markedly between Jivi(®) and Kovaltry(®); however, the FVIII activity in Jivi(®) (as measured by the peak height) tended to be higher than in Kovaltry(®). The CWA findings for monitoring Jivi(®) varied for monitoring Jivi(®) depending on the APTT reagents used, and sTF/FIX assay may be able to measure the EHL-FVIII.
format Online
Article
Text
id pubmed-7900842
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-79008422021-03-04 The Evaluation of APTT Reagents in Reference Plasma, Recombinant FVIII Products; Kovaltry® and Jivi® Using CWA, Including sTF/7FIX Assay Wada, Hideo Shiraki, Katsuya Matsumoto, Takeshi Ohishi, Kohshi Shimpo, Hideto Sakano, Yumi Nishii, Hiroko Shimaoka, Motomu Clin Appl Thromb Hemost Original Article The FVIII activity in patients treated with several extended half-life FVIII (EHL-FVIII) agents different when various activated partial thromboplastin time (APTT) reagents were used. The present study examined the difference in clot waveform analysis (CWA) findings and FVIII activity when various APTT reagents and CWA were used. The CWA including FVIII activity was measured using 12 APTT reagents, and the FIX activation based on a small amount of tissue factor assay (sTF/FIX) were examined in reference plasma (RP), EHL-FVIII (Jivi(®)) and Kovaltry(®). The 3 APTT reagents were associated with high variation in the peak time and height in the CWA when analyzing low concentrations of FVIII. The peak time and height could not be measured with one APTT reagent, and there were marked differences in the CWA findings between Jivi(®) and Kovaltry(®) among APTT reagents. Several APTT reagents showed a markedly lower FVIII activity with Jivi(®) than with Kovaltry(®). In the FVIII assay, the peak time measured with sTF/FIX did not differ markedly between Jivi(®) and Kovaltry(®); however, the FVIII activity in Jivi(®) (as measured by the peak height) tended to be higher than in Kovaltry(®). The CWA findings for monitoring Jivi(®) varied for monitoring Jivi(®) depending on the APTT reagents used, and sTF/FIX assay may be able to measure the EHL-FVIII. SAGE Publications 2021-02-19 /pmc/articles/PMC7900842/ /pubmed/33606948 http://dx.doi.org/10.1177/1076029620976913 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Article
Wada, Hideo
Shiraki, Katsuya
Matsumoto, Takeshi
Ohishi, Kohshi
Shimpo, Hideto
Sakano, Yumi
Nishii, Hiroko
Shimaoka, Motomu
The Evaluation of APTT Reagents in Reference Plasma, Recombinant FVIII Products; Kovaltry® and Jivi® Using CWA, Including sTF/7FIX Assay
title The Evaluation of APTT Reagents in Reference Plasma, Recombinant FVIII Products; Kovaltry® and Jivi® Using CWA, Including sTF/7FIX Assay
title_full The Evaluation of APTT Reagents in Reference Plasma, Recombinant FVIII Products; Kovaltry® and Jivi® Using CWA, Including sTF/7FIX Assay
title_fullStr The Evaluation of APTT Reagents in Reference Plasma, Recombinant FVIII Products; Kovaltry® and Jivi® Using CWA, Including sTF/7FIX Assay
title_full_unstemmed The Evaluation of APTT Reagents in Reference Plasma, Recombinant FVIII Products; Kovaltry® and Jivi® Using CWA, Including sTF/7FIX Assay
title_short The Evaluation of APTT Reagents in Reference Plasma, Recombinant FVIII Products; Kovaltry® and Jivi® Using CWA, Including sTF/7FIX Assay
title_sort evaluation of aptt reagents in reference plasma, recombinant fviii products; kovaltry® and jivi® using cwa, including stf/7fix assay
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7900842/
https://www.ncbi.nlm.nih.gov/pubmed/33606948
http://dx.doi.org/10.1177/1076029620976913
work_keys_str_mv AT wadahideo theevaluationofapttreagentsinreferenceplasmarecombinantfviiiproductskovaltryandjiviusingcwaincludingstf7fixassay
AT shirakikatsuya theevaluationofapttreagentsinreferenceplasmarecombinantfviiiproductskovaltryandjiviusingcwaincludingstf7fixassay
AT matsumototakeshi theevaluationofapttreagentsinreferenceplasmarecombinantfviiiproductskovaltryandjiviusingcwaincludingstf7fixassay
AT ohishikohshi theevaluationofapttreagentsinreferenceplasmarecombinantfviiiproductskovaltryandjiviusingcwaincludingstf7fixassay
AT shimpohideto theevaluationofapttreagentsinreferenceplasmarecombinantfviiiproductskovaltryandjiviusingcwaincludingstf7fixassay
AT sakanoyumi theevaluationofapttreagentsinreferenceplasmarecombinantfviiiproductskovaltryandjiviusingcwaincludingstf7fixassay
AT nishiihiroko theevaluationofapttreagentsinreferenceplasmarecombinantfviiiproductskovaltryandjiviusingcwaincludingstf7fixassay
AT shimaokamotomu theevaluationofapttreagentsinreferenceplasmarecombinantfviiiproductskovaltryandjiviusingcwaincludingstf7fixassay
AT wadahideo evaluationofapttreagentsinreferenceplasmarecombinantfviiiproductskovaltryandjiviusingcwaincludingstf7fixassay
AT shirakikatsuya evaluationofapttreagentsinreferenceplasmarecombinantfviiiproductskovaltryandjiviusingcwaincludingstf7fixassay
AT matsumototakeshi evaluationofapttreagentsinreferenceplasmarecombinantfviiiproductskovaltryandjiviusingcwaincludingstf7fixassay
AT ohishikohshi evaluationofapttreagentsinreferenceplasmarecombinantfviiiproductskovaltryandjiviusingcwaincludingstf7fixassay
AT shimpohideto evaluationofapttreagentsinreferenceplasmarecombinantfviiiproductskovaltryandjiviusingcwaincludingstf7fixassay
AT sakanoyumi evaluationofapttreagentsinreferenceplasmarecombinantfviiiproductskovaltryandjiviusingcwaincludingstf7fixassay
AT nishiihiroko evaluationofapttreagentsinreferenceplasmarecombinantfviiiproductskovaltryandjiviusingcwaincludingstf7fixassay
AT shimaokamotomu evaluationofapttreagentsinreferenceplasmarecombinantfviiiproductskovaltryandjiviusingcwaincludingstf7fixassay