Cargando…

A novel closed technique for ultrasound-guided plantar fascia release with a needle: review of 107 cases with a minimum follow-up of 24 months

ABSTRACT: BACKGROUND: This study aims to analyze the clinical outcome of a new ultrasound-guided surgery for partial plantar fasciotomy performed with a needle for treatment of plantar fasciitis. METHODS: We performed a retrospective review of 107 patients diagnosed with plantar fasciitis who underw...

Descripción completa

Detalles Bibliográficos
Autores principales: Iborra, A., Villanueva, M., Sanz-Ruiz, P., Martin, Antonio, Noriega, Concepción
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7903032/
https://www.ncbi.nlm.nih.gov/pubmed/33627158
http://dx.doi.org/10.1186/s13018-021-02302-y
_version_ 1783654657970667520
author Iborra, A.
Villanueva, M.
Sanz-Ruiz, P.
Martin, Antonio
Noriega, Concepción
author_facet Iborra, A.
Villanueva, M.
Sanz-Ruiz, P.
Martin, Antonio
Noriega, Concepción
author_sort Iborra, A.
collection PubMed
description ABSTRACT: BACKGROUND: This study aims to analyze the clinical outcome of a new ultrasound-guided surgery for partial plantar fasciotomy performed with a needle for treatment of plantar fasciitis. METHODS: We performed a retrospective review of 107 patients diagnosed with plantar fasciitis who underwent ultrasound-guided release of the plantar fascia. The series included 62 males (57.9%) and 45 females (42.1%) treated between April 2014 and February 2018, with a mean follow-up of 21.05 ± 10.96 months (7–66) and a minimum follow-up of 24 months. The mean age was 48.10 ± 10.27 years (27–72). Clinical assessments and ultrasound examination were carried out before treatment, after 1 week, and then after 1, 3, 12, and 24 months. The clinical assessment was based on a visual analog scale and the Foot and Ankle Disability Index. RESULTS: Heel pain improved in 92.5% (99) of patients, but not in 7.4% (8 patients). In the group of patients whose heel pain improved, 9 experienced overload on the lateral column and dorsum of the foot, which improved with the use of plantar orthoses and a rehabilitation program. We recorded no nerve complications (e.g., paresthesia), vascular injuries, or wound-related problems. CONCLUSION: Ultrasound-guided partial plantar fasciotomy with a needle is safe, since structures are under direct visualization of the surgeon and the risk of damage is minimal. Stitches are not necessary, and recovery is fast. Consequently, costs are low, and the patient can return to work quickly. This technique may represent a valid option for treatment of plantar fasciitis.
format Online
Article
Text
id pubmed-7903032
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-79030322021-02-24 A novel closed technique for ultrasound-guided plantar fascia release with a needle: review of 107 cases with a minimum follow-up of 24 months Iborra, A. Villanueva, M. Sanz-Ruiz, P. Martin, Antonio Noriega, Concepción J Orthop Surg Res Research Article ABSTRACT: BACKGROUND: This study aims to analyze the clinical outcome of a new ultrasound-guided surgery for partial plantar fasciotomy performed with a needle for treatment of plantar fasciitis. METHODS: We performed a retrospective review of 107 patients diagnosed with plantar fasciitis who underwent ultrasound-guided release of the plantar fascia. The series included 62 males (57.9%) and 45 females (42.1%) treated between April 2014 and February 2018, with a mean follow-up of 21.05 ± 10.96 months (7–66) and a minimum follow-up of 24 months. The mean age was 48.10 ± 10.27 years (27–72). Clinical assessments and ultrasound examination were carried out before treatment, after 1 week, and then after 1, 3, 12, and 24 months. The clinical assessment was based on a visual analog scale and the Foot and Ankle Disability Index. RESULTS: Heel pain improved in 92.5% (99) of patients, but not in 7.4% (8 patients). In the group of patients whose heel pain improved, 9 experienced overload on the lateral column and dorsum of the foot, which improved with the use of plantar orthoses and a rehabilitation program. We recorded no nerve complications (e.g., paresthesia), vascular injuries, or wound-related problems. CONCLUSION: Ultrasound-guided partial plantar fasciotomy with a needle is safe, since structures are under direct visualization of the surgeon and the risk of damage is minimal. Stitches are not necessary, and recovery is fast. Consequently, costs are low, and the patient can return to work quickly. This technique may represent a valid option for treatment of plantar fasciitis. BioMed Central 2021-02-24 /pmc/articles/PMC7903032/ /pubmed/33627158 http://dx.doi.org/10.1186/s13018-021-02302-y Text en © The Author(s) 2021 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Iborra, A.
Villanueva, M.
Sanz-Ruiz, P.
Martin, Antonio
Noriega, Concepción
A novel closed technique for ultrasound-guided plantar fascia release with a needle: review of 107 cases with a minimum follow-up of 24 months
title A novel closed technique for ultrasound-guided plantar fascia release with a needle: review of 107 cases with a minimum follow-up of 24 months
title_full A novel closed technique for ultrasound-guided plantar fascia release with a needle: review of 107 cases with a minimum follow-up of 24 months
title_fullStr A novel closed technique for ultrasound-guided plantar fascia release with a needle: review of 107 cases with a minimum follow-up of 24 months
title_full_unstemmed A novel closed technique for ultrasound-guided plantar fascia release with a needle: review of 107 cases with a minimum follow-up of 24 months
title_short A novel closed technique for ultrasound-guided plantar fascia release with a needle: review of 107 cases with a minimum follow-up of 24 months
title_sort novel closed technique for ultrasound-guided plantar fascia release with a needle: review of 107 cases with a minimum follow-up of 24 months
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7903032/
https://www.ncbi.nlm.nih.gov/pubmed/33627158
http://dx.doi.org/10.1186/s13018-021-02302-y
work_keys_str_mv AT iborraa anovelclosedtechniqueforultrasoundguidedplantarfasciareleasewithaneedlereviewof107caseswithaminimumfollowupof24months
AT villanuevam anovelclosedtechniqueforultrasoundguidedplantarfasciareleasewithaneedlereviewof107caseswithaminimumfollowupof24months
AT sanzruizp anovelclosedtechniqueforultrasoundguidedplantarfasciareleasewithaneedlereviewof107caseswithaminimumfollowupof24months
AT martinantonio anovelclosedtechniqueforultrasoundguidedplantarfasciareleasewithaneedlereviewof107caseswithaminimumfollowupof24months
AT noriegaconcepcion anovelclosedtechniqueforultrasoundguidedplantarfasciareleasewithaneedlereviewof107caseswithaminimumfollowupof24months
AT iborraa novelclosedtechniqueforultrasoundguidedplantarfasciareleasewithaneedlereviewof107caseswithaminimumfollowupof24months
AT villanuevam novelclosedtechniqueforultrasoundguidedplantarfasciareleasewithaneedlereviewof107caseswithaminimumfollowupof24months
AT sanzruizp novelclosedtechniqueforultrasoundguidedplantarfasciareleasewithaneedlereviewof107caseswithaminimumfollowupof24months
AT martinantonio novelclosedtechniqueforultrasoundguidedplantarfasciareleasewithaneedlereviewof107caseswithaminimumfollowupof24months
AT noriegaconcepcion novelclosedtechniqueforultrasoundguidedplantarfasciareleasewithaneedlereviewof107caseswithaminimumfollowupof24months