Cargando…

New technique: removal of embedded esophageal partially covered stent by endoscopic sub-stent space dissection

Both fully (FCSEMS) and partially (PCSEMS) covered self-expandable metal stents are used for the endoscopic management of leaks, perforations, and fistulas. PCSEMS have lower migration rates as their uncovered flanges allow for anchorage into the surrounding tissue, but this consequently makes them...

Descripción completa

Detalles Bibliográficos
Autores principales: Khamaysi, Iyad, Abadi, Sobhi, Hajj, Eisa, Yassin, Kamel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hellenic Society of Gastroenterology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7903574/
https://www.ncbi.nlm.nih.gov/pubmed/33654371
http://dx.doi.org/10.20524/aog.2021.0578
Descripción
Sumario:Both fully (FCSEMS) and partially (PCSEMS) covered self-expandable metal stents are used for the endoscopic management of leaks, perforations, and fistulas. PCSEMS have lower migration rates as their uncovered flanges allow for anchorage into the surrounding tissue, but this consequently makes them difficult to be removed, with reported cases of esophageal perforation during the removal of the embedded PCSEMS. Stent-in-stent technique is mostly used, where a FCSEMS is placed co-axially into an existing PCSEMS causing pressure necrosis and facilitating subsequent removal of both stents. This technique, although effective, is expensive, requiring the use of a second stent. In this report, we describe a series of 3 patients with embedded PCSEMS removed by a new endoscopic technique, i.e., endoscopic sub-stent space dissection, without using a second stent.