Cargando…

Comparison of Short-Segment Pedicle Instrumentation with Supplemental Hook Fixation under Axial Compression in Relation to Graft Positioning and Posterior Ligamentous Integrity: A Biomechanical Study on the Calf Spine

STUDY DESIGN: Biomechanical study. PURPOSE: This study investigates the benefits of supplemental hook fixation (SHF) on short-segment pedicle instrumentation (SSPI) in relation to anterior strut graft positioning. In addition, it seeks to determine whether the integrity of the posterior ligamentous...

Descripción completa

Detalles Bibliográficos
Autores principales: Muratli, Sedit Kivanc, Berk, Haluk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Spine Surgery 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7904481/
https://www.ncbi.nlm.nih.gov/pubmed/31992025
http://dx.doi.org/10.31616/asj.2019.0222
_version_ 1783654939248033792
author Muratli, Sedit Kivanc
Berk, Haluk
author_facet Muratli, Sedit Kivanc
Berk, Haluk
author_sort Muratli, Sedit Kivanc
collection PubMed
description STUDY DESIGN: Biomechanical study. PURPOSE: This study investigates the benefits of supplemental hook fixation (SHF) on short-segment pedicle instrumentation (SSPI) in relation to anterior strut graft positioning. In addition, it seeks to determine whether the integrity of the posterior ligamentous complex (PLC) affects the stability of the spinal construct. OVERVIEW OF LITERATURE: Implant and/or bone failure with progressive kyphotic deformity after SSPI is common. To prevent this, several approaches are available, including SHF, anterior strut grafting, use of longer spinal constructs, and extension of the fusion to additional adjacent segments. METHODS: A total of eight calf spines were instrumented with SSPI (n=4) and SHF (n=4) with strain gauges on the implants. Strain measurements were performed under axial compression in the following order: intact spine, corpectomy, ventral positioned strut grafting, posterior positioned strut grafting, ventral positioned grafting with resected PLC, and corpectomy with resected PLC. RESULTS: The SHF group showed slightly lower strain values than SSPI in instrumented corpectomy-only specimens, but there were no statistically significant differences between them (p >0.05). The SHF group was significantly more stable than SSPI when strut grafting is employed, regardless of the location of the grafts (p =0.000). In the SSPI group, ventral positioning of the graft contributed significantly to the stability (p =0.000). There was no statistically significant difference between the ventral or posterior positioning of the graft in the SHF group (p =0.187). In addition, the integrity of the PLC did not affect stability in either group (p >0.005). CONCLUSIONS: Although not statistically significant, our investigation demonstrated that the most stable method was the SHF along with ventral positioned strut graft. However, if the SSPI is the treatment of choice, ventral positioned strut graft support will be useful in minimizing the risk of implant failure and progressive kyphotic deformity.
format Online
Article
Text
id pubmed-7904481
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Korean Society of Spine Surgery
record_format MEDLINE/PubMed
spelling pubmed-79044812021-03-03 Comparison of Short-Segment Pedicle Instrumentation with Supplemental Hook Fixation under Axial Compression in Relation to Graft Positioning and Posterior Ligamentous Integrity: A Biomechanical Study on the Calf Spine Muratli, Sedit Kivanc Berk, Haluk Asian Spine J Clinical Study STUDY DESIGN: Biomechanical study. PURPOSE: This study investigates the benefits of supplemental hook fixation (SHF) on short-segment pedicle instrumentation (SSPI) in relation to anterior strut graft positioning. In addition, it seeks to determine whether the integrity of the posterior ligamentous complex (PLC) affects the stability of the spinal construct. OVERVIEW OF LITERATURE: Implant and/or bone failure with progressive kyphotic deformity after SSPI is common. To prevent this, several approaches are available, including SHF, anterior strut grafting, use of longer spinal constructs, and extension of the fusion to additional adjacent segments. METHODS: A total of eight calf spines were instrumented with SSPI (n=4) and SHF (n=4) with strain gauges on the implants. Strain measurements were performed under axial compression in the following order: intact spine, corpectomy, ventral positioned strut grafting, posterior positioned strut grafting, ventral positioned grafting with resected PLC, and corpectomy with resected PLC. RESULTS: The SHF group showed slightly lower strain values than SSPI in instrumented corpectomy-only specimens, but there were no statistically significant differences between them (p >0.05). The SHF group was significantly more stable than SSPI when strut grafting is employed, regardless of the location of the grafts (p =0.000). In the SSPI group, ventral positioning of the graft contributed significantly to the stability (p =0.000). There was no statistically significant difference between the ventral or posterior positioning of the graft in the SHF group (p =0.187). In addition, the integrity of the PLC did not affect stability in either group (p >0.005). CONCLUSIONS: Although not statistically significant, our investigation demonstrated that the most stable method was the SHF along with ventral positioned strut graft. However, if the SSPI is the treatment of choice, ventral positioned strut graft support will be useful in minimizing the risk of implant failure and progressive kyphotic deformity. Korean Society of Spine Surgery 2021-02 2020-01-30 /pmc/articles/PMC7904481/ /pubmed/31992025 http://dx.doi.org/10.31616/asj.2019.0222 Text en Copyright © 2021 by Korean Society of Spine Surgery This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Muratli, Sedit Kivanc
Berk, Haluk
Comparison of Short-Segment Pedicle Instrumentation with Supplemental Hook Fixation under Axial Compression in Relation to Graft Positioning and Posterior Ligamentous Integrity: A Biomechanical Study on the Calf Spine
title Comparison of Short-Segment Pedicle Instrumentation with Supplemental Hook Fixation under Axial Compression in Relation to Graft Positioning and Posterior Ligamentous Integrity: A Biomechanical Study on the Calf Spine
title_full Comparison of Short-Segment Pedicle Instrumentation with Supplemental Hook Fixation under Axial Compression in Relation to Graft Positioning and Posterior Ligamentous Integrity: A Biomechanical Study on the Calf Spine
title_fullStr Comparison of Short-Segment Pedicle Instrumentation with Supplemental Hook Fixation under Axial Compression in Relation to Graft Positioning and Posterior Ligamentous Integrity: A Biomechanical Study on the Calf Spine
title_full_unstemmed Comparison of Short-Segment Pedicle Instrumentation with Supplemental Hook Fixation under Axial Compression in Relation to Graft Positioning and Posterior Ligamentous Integrity: A Biomechanical Study on the Calf Spine
title_short Comparison of Short-Segment Pedicle Instrumentation with Supplemental Hook Fixation under Axial Compression in Relation to Graft Positioning and Posterior Ligamentous Integrity: A Biomechanical Study on the Calf Spine
title_sort comparison of short-segment pedicle instrumentation with supplemental hook fixation under axial compression in relation to graft positioning and posterior ligamentous integrity: a biomechanical study on the calf spine
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7904481/
https://www.ncbi.nlm.nih.gov/pubmed/31992025
http://dx.doi.org/10.31616/asj.2019.0222
work_keys_str_mv AT muratliseditkivanc comparisonofshortsegmentpedicleinstrumentationwithsupplementalhookfixationunderaxialcompressioninrelationtograftpositioningandposteriorligamentousintegrityabiomechanicalstudyonthecalfspine
AT berkhaluk comparisonofshortsegmentpedicleinstrumentationwithsupplementalhookfixationunderaxialcompressioninrelationtograftpositioningandposteriorligamentousintegrityabiomechanicalstudyonthecalfspine