Clinical Enhancement in AI-Based Post-processed Fast-Scan Low-Dose CBCT for Head and Neck Adaptive Radiotherapy
Purpose: To assess image quality and uncertainty in organ-at-risk segmentation on cone beam computed tomography (CBCT) enhanced by deep-learning convolutional neural network (DCNN) for head and neck cancer. Methods: An in-house DCNN was trained using forty post-operative head and neck cancer patient...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7904899/ https://www.ncbi.nlm.nih.gov/pubmed/33733226 http://dx.doi.org/10.3389/frai.2020.614384 |
_version_ | 1783655014532644864 |
---|---|
author | Chen, Wen Li, Yimin Yuan, Nimu Qi, Jinyi Dyer, Brandon A. Sensoy, Levent Benedict, Stanley H. Shang, Lu Rao, Shyam Rong, Yi |
author_facet | Chen, Wen Li, Yimin Yuan, Nimu Qi, Jinyi Dyer, Brandon A. Sensoy, Levent Benedict, Stanley H. Shang, Lu Rao, Shyam Rong, Yi |
author_sort | Chen, Wen |
collection | PubMed |
description | Purpose: To assess image quality and uncertainty in organ-at-risk segmentation on cone beam computed tomography (CBCT) enhanced by deep-learning convolutional neural network (DCNN) for head and neck cancer. Methods: An in-house DCNN was trained using forty post-operative head and neck cancer patients with their planning CT and first-fraction CBCT images. Additional fifteen patients with repeat simulation CT (rCT) and CBCT scan taken on the same day (oCBCT) were used for validation and clinical utility assessment. Enhanced CBCT (eCBCT) images were generated from the oCBCT using the in-house DCNN. Quantitative imaging quality improvement was evaluated using HU accuracy, signal-to-noise-ratio (SNR), and structural similarity index measure (SSIM). Organs-at-risk (OARs) were delineated on o/eCBCT and compared with manual structures on the same day rCT. Contour accuracy was assessed using dice similarity coefficient (DSC), Hausdorff distance (HD), and center of mass (COM) displacement. Qualitative assessment of users’ confidence in manual segmenting OARs was performed on both eCBCT and oCBCT by visual scoring. Results: eCBCT organs-at-risk had significant improvement on mean pixel values, SNR (p < 0.05), and SSIM (p < 0.05) compared to oCBCT images. Mean DSC of eCBCT-to-rCT (0.83 ± 0.06) was higher than oCBCT-to-rCT (0.70 ± 0.13). Improvement was observed for mean HD of eCBCT-to-rCT (0.42 ± 0.13 cm) vs. oCBCT-to-rCT (0.72 ± 0.25 cm). Mean COM was less for eCBCT-to-rCT (0.28 ± 0.19 cm) comparing to oCBCT-to-rCT (0.44 ± 0.22 cm). Visual scores showed OAR segmentation was more accessible on eCBCT than oCBCT images. Conclusion: DCNN improved fast-scan low-dose CBCT in terms of the HU accuracy, image contrast, and OAR delineation accuracy, presenting potential of eCBCT for adaptive radiotherapy. |
format | Online Article Text |
id | pubmed-7904899 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-79048992021-03-16 Clinical Enhancement in AI-Based Post-processed Fast-Scan Low-Dose CBCT for Head and Neck Adaptive Radiotherapy Chen, Wen Li, Yimin Yuan, Nimu Qi, Jinyi Dyer, Brandon A. Sensoy, Levent Benedict, Stanley H. Shang, Lu Rao, Shyam Rong, Yi Front Artif Intell Artificial Intelligence Purpose: To assess image quality and uncertainty in organ-at-risk segmentation on cone beam computed tomography (CBCT) enhanced by deep-learning convolutional neural network (DCNN) for head and neck cancer. Methods: An in-house DCNN was trained using forty post-operative head and neck cancer patients with their planning CT and first-fraction CBCT images. Additional fifteen patients with repeat simulation CT (rCT) and CBCT scan taken on the same day (oCBCT) were used for validation and clinical utility assessment. Enhanced CBCT (eCBCT) images were generated from the oCBCT using the in-house DCNN. Quantitative imaging quality improvement was evaluated using HU accuracy, signal-to-noise-ratio (SNR), and structural similarity index measure (SSIM). Organs-at-risk (OARs) were delineated on o/eCBCT and compared with manual structures on the same day rCT. Contour accuracy was assessed using dice similarity coefficient (DSC), Hausdorff distance (HD), and center of mass (COM) displacement. Qualitative assessment of users’ confidence in manual segmenting OARs was performed on both eCBCT and oCBCT by visual scoring. Results: eCBCT organs-at-risk had significant improvement on mean pixel values, SNR (p < 0.05), and SSIM (p < 0.05) compared to oCBCT images. Mean DSC of eCBCT-to-rCT (0.83 ± 0.06) was higher than oCBCT-to-rCT (0.70 ± 0.13). Improvement was observed for mean HD of eCBCT-to-rCT (0.42 ± 0.13 cm) vs. oCBCT-to-rCT (0.72 ± 0.25 cm). Mean COM was less for eCBCT-to-rCT (0.28 ± 0.19 cm) comparing to oCBCT-to-rCT (0.44 ± 0.22 cm). Visual scores showed OAR segmentation was more accessible on eCBCT than oCBCT images. Conclusion: DCNN improved fast-scan low-dose CBCT in terms of the HU accuracy, image contrast, and OAR delineation accuracy, presenting potential of eCBCT for adaptive radiotherapy. Frontiers Media S.A. 2021-02-11 /pmc/articles/PMC7904899/ /pubmed/33733226 http://dx.doi.org/10.3389/frai.2020.614384 Text en Copyright © 2021 Chen, Li, Yuan, Qi, Dyer, Sensoy, Benedict, Shang, Rao and Rong. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Artificial Intelligence Chen, Wen Li, Yimin Yuan, Nimu Qi, Jinyi Dyer, Brandon A. Sensoy, Levent Benedict, Stanley H. Shang, Lu Rao, Shyam Rong, Yi Clinical Enhancement in AI-Based Post-processed Fast-Scan Low-Dose CBCT for Head and Neck Adaptive Radiotherapy |
title | Clinical Enhancement in AI-Based Post-processed Fast-Scan Low-Dose CBCT for Head and Neck Adaptive Radiotherapy |
title_full | Clinical Enhancement in AI-Based Post-processed Fast-Scan Low-Dose CBCT for Head and Neck Adaptive Radiotherapy |
title_fullStr | Clinical Enhancement in AI-Based Post-processed Fast-Scan Low-Dose CBCT for Head and Neck Adaptive Radiotherapy |
title_full_unstemmed | Clinical Enhancement in AI-Based Post-processed Fast-Scan Low-Dose CBCT for Head and Neck Adaptive Radiotherapy |
title_short | Clinical Enhancement in AI-Based Post-processed Fast-Scan Low-Dose CBCT for Head and Neck Adaptive Radiotherapy |
title_sort | clinical enhancement in ai-based post-processed fast-scan low-dose cbct for head and neck adaptive radiotherapy |
topic | Artificial Intelligence |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7904899/ https://www.ncbi.nlm.nih.gov/pubmed/33733226 http://dx.doi.org/10.3389/frai.2020.614384 |
work_keys_str_mv | AT chenwen clinicalenhancementinaibasedpostprocessedfastscanlowdosecbctforheadandneckadaptiveradiotherapy AT liyimin clinicalenhancementinaibasedpostprocessedfastscanlowdosecbctforheadandneckadaptiveradiotherapy AT yuannimu clinicalenhancementinaibasedpostprocessedfastscanlowdosecbctforheadandneckadaptiveradiotherapy AT qijinyi clinicalenhancementinaibasedpostprocessedfastscanlowdosecbctforheadandneckadaptiveradiotherapy AT dyerbrandona clinicalenhancementinaibasedpostprocessedfastscanlowdosecbctforheadandneckadaptiveradiotherapy AT sensoylevent clinicalenhancementinaibasedpostprocessedfastscanlowdosecbctforheadandneckadaptiveradiotherapy AT benedictstanleyh clinicalenhancementinaibasedpostprocessedfastscanlowdosecbctforheadandneckadaptiveradiotherapy AT shanglu clinicalenhancementinaibasedpostprocessedfastscanlowdosecbctforheadandneckadaptiveradiotherapy AT raoshyam clinicalenhancementinaibasedpostprocessedfastscanlowdosecbctforheadandneckadaptiveradiotherapy AT rongyi clinicalenhancementinaibasedpostprocessedfastscanlowdosecbctforheadandneckadaptiveradiotherapy |