Cargando…

Age-related laryngoscopic visual acuity

BACKGROUND: Endotracheal intubation by direct laryngoscopy is a mainstay of advanced airway management performed both in the prehospital environment and in the Emergency Department. Many factors may affect the quality of view during direct laryngoscopy, one of them being the visual acuity (VA) of th...

Descripción completa

Detalles Bibliográficos
Autores principales: Mathews, Abdul-Maajid, Stein, Christopher, Richter, Marietjie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: African Federation for Emergency Medicine 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7905451/
https://www.ncbi.nlm.nih.gov/pubmed/33680745
http://dx.doi.org/10.1016/j.afjem.2020.12.002
_version_ 1783655113749954560
author Mathews, Abdul-Maajid
Stein, Christopher
Richter, Marietjie
author_facet Mathews, Abdul-Maajid
Stein, Christopher
Richter, Marietjie
author_sort Mathews, Abdul-Maajid
collection PubMed
description BACKGROUND: Endotracheal intubation by direct laryngoscopy is a mainstay of advanced airway management performed both in the prehospital environment and in the Emergency Department. Many factors may affect the quality of view during direct laryngoscopy, one of them being the visual acuity (VA) of the intubator under these demanding conditions. While some individual variation in VA is to be expected in younger populations, VA naturally deteriorates in older populations particularly beyond the age of 40 years. This study aimed to describe VA in a younger (n=19) and an older (≥40 years of age, n=20) cohort of intubators at baseline and during simulated adult laryngoscopy, and to compare VA between these two age cohorts. METHODS: A baseline near VA test was done using a Sloan Early Treatment Diabetic Retinopathy Study (EDTRS) near vision chart at 40 cm under ambient indoor light. Participants in both age cohorts were then requested to perform laryngoscopy using an airway simulator at 40 cm viewing distance and again at a viewing distance of their choice. Both binocular and monocular VA were tested using a near VA chart placed anterior to the vocal cords of the airway trainer. VA was quantified using the logarithm of the minimum angle of resolution (logMAR). Differences in VA between age cohorts were assessed using independent samples t-tests and differences within age cohorts were assessed using paired samples t-tests. RESULTS: Binocular and monocular near VA was significantly reduced in the older cohort compared to the younger cohort at baseline (both eyes −0.129 logMAR; p = 0.04, right eye −0.147 logMAR; p = 0.005, left eye −0.197 logMAR; p = 0.002). Within each age cohort VA was significantly reduced during laryngoscopy at a fixed viewing distance (younger; both eyes −0.111 logMAR; p < 0.001, right eye −0.095 logMAR; p < 0.001, left eye −0.105 logMAR; p < 0.001; older; both eyes −0,08 logMAR; p < 0.001, right eye −0.110 logMAR; p < 0.001, left eye −0.065 logMAR; p = 0.01) but this was improved by reducing viewing distance. CONCLUSION: Increased age was associated with a significant reduction in VA at baseline and during laryngoscopy, which can be partially compensated for by adjusting viewing distance. Although it is currently unknown to what extent this age-related reduction of VA might negatively affect time to place an endotracheal tube or success of placement under direct vision, older intubators should be aware of this effect and consider specialized corrective eyewear in order to maintain an adequate level of VA.
format Online
Article
Text
id pubmed-7905451
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher African Federation for Emergency Medicine
record_format MEDLINE/PubMed
spelling pubmed-79054512021-03-04 Age-related laryngoscopic visual acuity Mathews, Abdul-Maajid Stein, Christopher Richter, Marietjie Afr J Emerg Med Original Article BACKGROUND: Endotracheal intubation by direct laryngoscopy is a mainstay of advanced airway management performed both in the prehospital environment and in the Emergency Department. Many factors may affect the quality of view during direct laryngoscopy, one of them being the visual acuity (VA) of the intubator under these demanding conditions. While some individual variation in VA is to be expected in younger populations, VA naturally deteriorates in older populations particularly beyond the age of 40 years. This study aimed to describe VA in a younger (n=19) and an older (≥40 years of age, n=20) cohort of intubators at baseline and during simulated adult laryngoscopy, and to compare VA between these two age cohorts. METHODS: A baseline near VA test was done using a Sloan Early Treatment Diabetic Retinopathy Study (EDTRS) near vision chart at 40 cm under ambient indoor light. Participants in both age cohorts were then requested to perform laryngoscopy using an airway simulator at 40 cm viewing distance and again at a viewing distance of their choice. Both binocular and monocular VA were tested using a near VA chart placed anterior to the vocal cords of the airway trainer. VA was quantified using the logarithm of the minimum angle of resolution (logMAR). Differences in VA between age cohorts were assessed using independent samples t-tests and differences within age cohorts were assessed using paired samples t-tests. RESULTS: Binocular and monocular near VA was significantly reduced in the older cohort compared to the younger cohort at baseline (both eyes −0.129 logMAR; p = 0.04, right eye −0.147 logMAR; p = 0.005, left eye −0.197 logMAR; p = 0.002). Within each age cohort VA was significantly reduced during laryngoscopy at a fixed viewing distance (younger; both eyes −0.111 logMAR; p < 0.001, right eye −0.095 logMAR; p < 0.001, left eye −0.105 logMAR; p < 0.001; older; both eyes −0,08 logMAR; p < 0.001, right eye −0.110 logMAR; p < 0.001, left eye −0.065 logMAR; p = 0.01) but this was improved by reducing viewing distance. CONCLUSION: Increased age was associated with a significant reduction in VA at baseline and during laryngoscopy, which can be partially compensated for by adjusting viewing distance. Although it is currently unknown to what extent this age-related reduction of VA might negatively affect time to place an endotracheal tube or success of placement under direct vision, older intubators should be aware of this effect and consider specialized corrective eyewear in order to maintain an adequate level of VA. African Federation for Emergency Medicine 2021-06 2021-02-19 /pmc/articles/PMC7905451/ /pubmed/33680745 http://dx.doi.org/10.1016/j.afjem.2020.12.002 Text en © 2018 Published by Elsevier Ltd. CC BY-NC-ND 4.0. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Mathews, Abdul-Maajid
Stein, Christopher
Richter, Marietjie
Age-related laryngoscopic visual acuity
title Age-related laryngoscopic visual acuity
title_full Age-related laryngoscopic visual acuity
title_fullStr Age-related laryngoscopic visual acuity
title_full_unstemmed Age-related laryngoscopic visual acuity
title_short Age-related laryngoscopic visual acuity
title_sort age-related laryngoscopic visual acuity
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7905451/
https://www.ncbi.nlm.nih.gov/pubmed/33680745
http://dx.doi.org/10.1016/j.afjem.2020.12.002
work_keys_str_mv AT mathewsabdulmaajid agerelatedlaryngoscopicvisualacuity
AT steinchristopher agerelatedlaryngoscopicvisualacuity
AT richtermarietjie agerelatedlaryngoscopicvisualacuity