Cargando…

The occurrence rate and clinical application of Osteo-line on the femur neck

BACKGROUND: This study was done to observe the incidence of Osteo-line on the femur neck and to explore the clinical application of Osteo-line in osteotomy. METHODS: Eighty-nine adult femur specimens were selected to observe the incidence of Osteo-line on the femur neck. From August 2015 to January...

Descripción completa

Detalles Bibliográficos
Autores principales: Zou, Mingchen, Wu, Haotian, Yao, Shuangquan, Ren, Dong, Liu, Song, Liu, Yueju, Song, Zhaohui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7905579/
https://www.ncbi.nlm.nih.gov/pubmed/33632253
http://dx.doi.org/10.1186/s13018-021-02289-6
Descripción
Sumario:BACKGROUND: This study was done to observe the incidence of Osteo-line on the femur neck and to explore the clinical application of Osteo-line in osteotomy. METHODS: Eighty-nine adult femur specimens were selected to observe the incidence of Osteo-line on the femur neck. From August 2015 to January 2019, a total of 278 patients who completed unilateral hip arthroplasty at the Third Hospital of Hebei Medical University were retrospectively included. Patients who accepted osteotomy via Osteo-line on the femur neck were defined as the experimental group (n = 139), and patients who accepted osteotomy via traditional method (The femoral distance 1.5 cm above the trochanter was retained for osteotomy by visual inspection.) were defined as the control group (n = 139). According to the postoperative pelvic X-ray, Photoshop was used to evaluate the leg length discrepancy (LLD) by the CFR-T-LT method. RESULTS: Among the 89 specimens, the incidence of anterior Osteo-line was 75.28%, and the incidence of posterior Osteo-line was 100%. According to the clinical application results, the incidence of anterior Osteo-line on the femur neck was 80%, and the incidence of posterior Osteo-line was 100%. The Osteo-line was clearer than those on the femoral specimens. Twenty-six cases had LLD greater than 1 cm (9.29%), including 2 cases in the experimental group and 24 cases in the control group. The average postoperative LLD in the experimental group (0.19 ± 0.38 mm) was significantly shorter than in the control group (0.54 ± 0.51 mm)(P = 0.005). CONCLUSION: The incidence of Osteo-line on the femur neck was high, and patients who accepted osteotomy via Osteo-line on the femur neck can achieve shorter postoperative LLD than the control group.