Effect of implantation site of the His bundle pacing leads on pacing parameters: a single-center experience
BACKGROUND: HB pacing is a promising approach to achieve physiological pacing, but its efficacy and long-term effects require further validation. In current study, we deemed to investigate the effect of the His bundle pacing (HBP) lead location on pacing parameters. METHODS: 2D echocardiography imag...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7905646/ https://www.ncbi.nlm.nih.gov/pubmed/33627074 http://dx.doi.org/10.1186/s12872-020-01842-1 |
Sumario: | BACKGROUND: HB pacing is a promising approach to achieve physiological pacing, but its efficacy and long-term effects require further validation. In current study, we deemed to investigate the effect of the His bundle pacing (HBP) lead location on pacing parameters. METHODS: 2D echocardiography imaging was performed after successful implantation, according to which the patients were divided into groups A (whose His lead tips were at the atrial side) and B (whose His lead tips were at the ventricular side). The capture thresholds, sensing values, and H-V intervals between the two groups were compared. RESULTS: Thirteen patients were in group A and 16 patients were in group B. The average capture thresholds during, 1 month, and 1 year after operation were 1.20 ± 0.34, 0.69 ± 0.29, and 0.92 ± 0.80 V/0.5 ms for group A and 1.14 ± 0.43, 0.81 ± 0.39, and 0.98 ± 0.59 V/0.5 ms for group B, respectively. The difference between the two groups was not significant. The threshold values in both groups decreased significantly in 1 month and slightly increased in 1 year. The sensing values of group A were 1.87 ± 0.82, 1.95 ± 0.76, and 1.88 ± 0.75 mV, while those of group B were 4.53 ± 1.37, 4.69 ± 1.38, and 4.59 ± 1.42 mV. The difference among the three time points was not significant. However, the sensing values in group A were consistently significantly lower than those in group B. The HV interval in group A was significantly longer than that in group B. CONCLUSIONS: The implantation site of HBP leads has a significant effect on sensing values for that His leads crossing the tricuspid annulus toward the ventricle are associated with higher sensing values, compared to a more proximal location. Meanwhile, lead location has no evident effect on capture thresholds that is improved significantly shortly after operation. |
---|