Cargando…

Study Design and Data Analysis of Artificial Pancreas Device Systems with Closed-Loop Glucose-Sensing Insulin Delivery

OBJECTIVE: The objective of this article is to provide a high-profile review and discussion on the study design and statistical analysis of pivotal clinical trials conducted to demonstrate the safety and effectiveness of closed-loop investigational artificial pancreas device systems (APDSs) in prema...

Descripción completa

Detalles Bibliográficos
Autores principales: Shankara, Sravya B., Liu, Yujia, Zheng, Qingfeng, Guo, Jing, Wang, Guixia, Zhang, Bo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7906816/
https://www.ncbi.nlm.nih.gov/pubmed/33679974
http://dx.doi.org/10.1155/2021/8812695
_version_ 1783655368886321152
author Shankara, Sravya B.
Liu, Yujia
Zheng, Qingfeng
Guo, Jing
Wang, Guixia
Zhang, Bo
author_facet Shankara, Sravya B.
Liu, Yujia
Zheng, Qingfeng
Guo, Jing
Wang, Guixia
Zhang, Bo
author_sort Shankara, Sravya B.
collection PubMed
description OBJECTIVE: The objective of this article is to provide a high-profile review and discussion on the study design and statistical analysis of pivotal clinical trials conducted to demonstrate the safety and effectiveness of closed-loop investigational artificial pancreas device systems (APDSs) in premarket approval applications. METHODS: The United States Food and Drug Administration (FDA) guidance on the content of investigational device exemption and premarket approval applications for APDSs is reviewed with special emphasis on study design and statistical analysis of the pivotal clinical trials. The two pivotal studies for the MiniMed 670G hybrid closed-loop system by Medtronic in their premarket approval application are summarized and discussed. RESULTS: The United States FDA established detailed recommendations on the study design and statistical analysis of pivotal clinical trials for the industry that seek market investigational APDSs and for FDA scientific reviewers that regulate the device applications. The recommendations cover specifics regarding patient population, clinical endpoints, and strategies for data analysis. However, the two pivotal studies that demonstrated the effectiveness of the FDA-approved MiniMed 670G hybrid closed-loop system were not typical randomized controlled trials as per FDA recommendations. CONCLUSION: The development and regulation of investigational APDSs require careful and sophisticated clinical study designs and data analysis in premarket approval applications. The regulatory evaluation process of the APDSs is rather complicated since the devices consist of multiple components that collaboratively function to mimic human pancreases.
format Online
Article
Text
id pubmed-7906816
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-79068162021-03-04 Study Design and Data Analysis of Artificial Pancreas Device Systems with Closed-Loop Glucose-Sensing Insulin Delivery Shankara, Sravya B. Liu, Yujia Zheng, Qingfeng Guo, Jing Wang, Guixia Zhang, Bo Int J Endocrinol Review Article OBJECTIVE: The objective of this article is to provide a high-profile review and discussion on the study design and statistical analysis of pivotal clinical trials conducted to demonstrate the safety and effectiveness of closed-loop investigational artificial pancreas device systems (APDSs) in premarket approval applications. METHODS: The United States Food and Drug Administration (FDA) guidance on the content of investigational device exemption and premarket approval applications for APDSs is reviewed with special emphasis on study design and statistical analysis of the pivotal clinical trials. The two pivotal studies for the MiniMed 670G hybrid closed-loop system by Medtronic in their premarket approval application are summarized and discussed. RESULTS: The United States FDA established detailed recommendations on the study design and statistical analysis of pivotal clinical trials for the industry that seek market investigational APDSs and for FDA scientific reviewers that regulate the device applications. The recommendations cover specifics regarding patient population, clinical endpoints, and strategies for data analysis. However, the two pivotal studies that demonstrated the effectiveness of the FDA-approved MiniMed 670G hybrid closed-loop system were not typical randomized controlled trials as per FDA recommendations. CONCLUSION: The development and regulation of investigational APDSs require careful and sophisticated clinical study designs and data analysis in premarket approval applications. The regulatory evaluation process of the APDSs is rather complicated since the devices consist of multiple components that collaboratively function to mimic human pancreases. Hindawi 2021-02-18 /pmc/articles/PMC7906816/ /pubmed/33679974 http://dx.doi.org/10.1155/2021/8812695 Text en Copyright © 2021 Sravya B. Shankara et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Shankara, Sravya B.
Liu, Yujia
Zheng, Qingfeng
Guo, Jing
Wang, Guixia
Zhang, Bo
Study Design and Data Analysis of Artificial Pancreas Device Systems with Closed-Loop Glucose-Sensing Insulin Delivery
title Study Design and Data Analysis of Artificial Pancreas Device Systems with Closed-Loop Glucose-Sensing Insulin Delivery
title_full Study Design and Data Analysis of Artificial Pancreas Device Systems with Closed-Loop Glucose-Sensing Insulin Delivery
title_fullStr Study Design and Data Analysis of Artificial Pancreas Device Systems with Closed-Loop Glucose-Sensing Insulin Delivery
title_full_unstemmed Study Design and Data Analysis of Artificial Pancreas Device Systems with Closed-Loop Glucose-Sensing Insulin Delivery
title_short Study Design and Data Analysis of Artificial Pancreas Device Systems with Closed-Loop Glucose-Sensing Insulin Delivery
title_sort study design and data analysis of artificial pancreas device systems with closed-loop glucose-sensing insulin delivery
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7906816/
https://www.ncbi.nlm.nih.gov/pubmed/33679974
http://dx.doi.org/10.1155/2021/8812695
work_keys_str_mv AT shankarasravyab studydesignanddataanalysisofartificialpancreasdevicesystemswithclosedloopglucosesensinginsulindelivery
AT liuyujia studydesignanddataanalysisofartificialpancreasdevicesystemswithclosedloopglucosesensinginsulindelivery
AT zhengqingfeng studydesignanddataanalysisofartificialpancreasdevicesystemswithclosedloopglucosesensinginsulindelivery
AT guojing studydesignanddataanalysisofartificialpancreasdevicesystemswithclosedloopglucosesensinginsulindelivery
AT wangguixia studydesignanddataanalysisofartificialpancreasdevicesystemswithclosedloopglucosesensinginsulindelivery
AT zhangbo studydesignanddataanalysisofartificialpancreasdevicesystemswithclosedloopglucosesensinginsulindelivery