ISCEV extended protocol for VEP methods of estimation of visual acuity
The International Society for Clinical Electrophysiology of Vision (ISCEV) standard for visual evoked potentials (VEPs) describes a minimum procedure for clinical VEP testing and encourages more extensive testing. This ISCEV extended protocol is an extension to the VEP standard. It describes procedu...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7906925/ https://www.ncbi.nlm.nih.gov/pubmed/32676804 http://dx.doi.org/10.1007/s10633-020-09780-1 |
_version_ | 1783655389446799360 |
---|---|
author | Hamilton, Ruth Bach, Michael Heinrich, Sven P. Hoffmann, Michael B. Odom, J. Vernon McCulloch, Daphne L. Thompson, Dorothy A. |
author_facet | Hamilton, Ruth Bach, Michael Heinrich, Sven P. Hoffmann, Michael B. Odom, J. Vernon McCulloch, Daphne L. Thompson, Dorothy A. |
author_sort | Hamilton, Ruth |
collection | PubMed |
description | The International Society for Clinical Electrophysiology of Vision (ISCEV) standard for visual evoked potentials (VEPs) describes a minimum procedure for clinical VEP testing and encourages more extensive testing. This ISCEV extended protocol is an extension to the VEP standard. It describes procedures for recording multiple VEPs to a range of sizes of pattern stimuli to establish the VEP spatial frequency limit (threshold) and for relating this limit to visual acuity. |
format | Online Article Text |
id | pubmed-7906925 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-79069252021-03-09 ISCEV extended protocol for VEP methods of estimation of visual acuity Hamilton, Ruth Bach, Michael Heinrich, Sven P. Hoffmann, Michael B. Odom, J. Vernon McCulloch, Daphne L. Thompson, Dorothy A. Doc Ophthalmol ISCEV Standards The International Society for Clinical Electrophysiology of Vision (ISCEV) standard for visual evoked potentials (VEPs) describes a minimum procedure for clinical VEP testing and encourages more extensive testing. This ISCEV extended protocol is an extension to the VEP standard. It describes procedures for recording multiple VEPs to a range of sizes of pattern stimuli to establish the VEP spatial frequency limit (threshold) and for relating this limit to visual acuity. Springer Berlin Heidelberg 2020-07-16 2021 /pmc/articles/PMC7906925/ /pubmed/32676804 http://dx.doi.org/10.1007/s10633-020-09780-1 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | ISCEV Standards Hamilton, Ruth Bach, Michael Heinrich, Sven P. Hoffmann, Michael B. Odom, J. Vernon McCulloch, Daphne L. Thompson, Dorothy A. ISCEV extended protocol for VEP methods of estimation of visual acuity |
title | ISCEV extended protocol for VEP methods of estimation of visual acuity |
title_full | ISCEV extended protocol for VEP methods of estimation of visual acuity |
title_fullStr | ISCEV extended protocol for VEP methods of estimation of visual acuity |
title_full_unstemmed | ISCEV extended protocol for VEP methods of estimation of visual acuity |
title_short | ISCEV extended protocol for VEP methods of estimation of visual acuity |
title_sort | iscev extended protocol for vep methods of estimation of visual acuity |
topic | ISCEV Standards |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7906925/ https://www.ncbi.nlm.nih.gov/pubmed/32676804 http://dx.doi.org/10.1007/s10633-020-09780-1 |
work_keys_str_mv | AT hamiltonruth iscevextendedprotocolforvepmethodsofestimationofvisualacuity AT bachmichael iscevextendedprotocolforvepmethodsofestimationofvisualacuity AT heinrichsvenp iscevextendedprotocolforvepmethodsofestimationofvisualacuity AT hoffmannmichaelb iscevextendedprotocolforvepmethodsofestimationofvisualacuity AT odomjvernon iscevextendedprotocolforvepmethodsofestimationofvisualacuity AT mccullochdaphnel iscevextendedprotocolforvepmethodsofestimationofvisualacuity AT thompsondorothya iscevextendedprotocolforvepmethodsofestimationofvisualacuity |